COOPER&HUNTER Heat Pumps

Compare 69 COOPER&HUNTER heat pumps by efficiency and total cost of ownership. Operation costs are calculated based on your location and home — enter your details above for personalized estimates.

NameBrandRefrigerantPerformanceOperation
C&H 9K-Btu Console 27.2 SEER2 Mini Split H-Heat Pump (-22°F) E-Star: 15.1 EER/10.9 HSPF (R454B)
$1,680 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F1.042,7001.042,7001.024,700
5F1.8411,3001.832,0001.8411,300
17F2.719,8002.492,8002.1712,200
47F4.49,0004.964,4003.516,100
95F4.49,0005.713,7003.4913,700
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$1,680
Energy Cost-
10-Year Cost-
C&H 9K-Btu 26 SEER2 Mini Split H-Heat Pump (-22°F) Wifi, E-Star: 15 EER/12.5 HSPF (R454B)
$1,520 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F1.072,0001.072,0001.245,800
5F1.811,5001.84,0001.811,500
17F2.5910,0002.345,2001.7512,800
47F3.6312,0005.573,8003.316,000
95F4.49,0008.793,6003.3513,500
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$1,520
Energy Cost-
10-Year Cost-
C&H 9K-Btu Console 26 SEER2 Mini Split Heat Pump (-13°F) Wifi, E-Star: 16.2 EER/13.9 HSPF (R454B)
$1,560 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F0.848000.848001.424,600
5F2.278,6001.781,7002.278,600
17F2.99,0003.353,2002.499,600
47F4.329,0005.545,1003.3812,700
95F4.719,0005.864,0003.8612,900
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$1,560
Energy Cost-
10-Year Cost-
C&H 12K-Btu 25 SEER2 Console Mini Split H-Heat Pump (-22°F) Wifi, E-Star: 12.5 EER/10.5 HSPF (R454B)
$1,710 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F1.13,0001.13,0001.044,800
5F1.8811,3001.992,1001.8811,300
17F2.719,8002.662,9002.1412,400
47F3.8612,0004.964,4003.516,100
95F3.6612,0005.713,7003.5714,000
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$1,710
Energy Cost-
10-Year Cost-
C&H 9K-Btu 24.6 SEER2 Mini Split Heat Pump (-13°F) Wifi, E-Star: 14.7 EER/13 HSPF (R454B)
$1,400 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F1.764,2001.764,2001.535,000
5F2.338,2002.113,6002.338,200
17F2.88,6002.473,8002.4710,200
47F3.6610,0005.354,2003.3614,200
95F4.329,0004.333,1003.910,900
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$1,400
Energy Cost-
10-Year Cost-
C&H 12K-Btu 24.6 SEER2 Console Mini Split Heat Pump (-13°F) Wifi, E-Star: 12.7 EER/11 HSPF (R454B)
$1,610 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F0.818000.818001.424,600
5F2.518,9001.781,7002.518,900
17F2.879,0003.353,2002.499,600
47F3.9112,0005.545,1003.1512,900
95F3.7412,0005.864,0003.3713,100
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$1,610
Energy Cost-
10-Year Cost-
C&H 12K-Btu 24 SEER2 Mini Split H-Heat Pump (-22°F) Wifi, E-Star: 13.2 EER/10.5 HSPF (R454B)
$1,540 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F1.072,0001.072,0001.255,900
5F1.811,5001.84,0001.811,500
17F2.5910,0002.345,2001.7512,800
47F3.6312,0004.843,8003.3516,000
95F3.8612,0008.793,6003.3513,500
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$1,540
Energy Cost-
10-Year Cost-
C&H 18K-Btu 24 SEER2 Mini Split Heat Pump (-13°F) Wifi, E-Star: 13.5 EER/11.1 HSPF (R454B)
$1,940 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F1.322,3001.322,3001.78,200
5F2.3513,0002.033,6002.3513,000
17F2.5913,0002.54,7002.4315,000
47F3.8218,0005.437,6003.6822,000
95F3.9718,0003.013,6003.4520,000
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$1,940
Energy Cost-
10-Year Cost-
C&H 9K-Btu Slim Cassette 24 SEER2 Mini Split H-Heat Pump (-22°F) E-Star: 14.6 EER/12.1 HSPF (R454B)
$2,060 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F0.569000.569001.15,100
5F1.8310,6001.854,1001.8310,600
17F2.449,0002.175,1002.011,900
47F3.7110,9003.713,8003.0213,900
95F4.259,0007.824,0003.2912,900
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$2,060
Energy Cost-
10-Year Cost-
C&H 16K-Btu 23.8 SEER2 Console Mini Split Heat Pump AC (-13°F) E-Star: 12.5 EER/13.5 HSPF (R454B)
$2,100 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F0.711,0000.711,0001.568,000
5F2.1613,1001.562,6002.1613,100
17F2.7514,1002.484,4002.5814,600
47F3.3717,0005.497,3003.6722,900
95F3.6616,0003.134,7003.318,000
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$2,100
Energy Cost-
10-Year Cost-
Cooper & Hunter 6k-Btu 23.5 SEER Heat Pump Mini Split 220v AC (-22°F) (R410a)
$1,369 at MiniSplitWarehouse
COOPER&HUNTER R-410A
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
5F1.847,1001.883,2001.927,200
17F2.57,5002.234,1002.3810,000
47F3.737,0004.983,4002.8611,400
95F4.46,0003.784,9003.411,500
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$1,369
Energy Cost-
10-Year Cost-
C&H 24K-Btu 23.5 SEER2 Mini Split Heat Pump (-13°F) Wifi, E-Star: 13 EER/10 HSPF (R454B)
$2,080 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F1.022,2001.022,2001.5411,000
5F2.1517,8001.725,1002.1517,800
17F2.519,5002.457,2002.4221,300
47F3.0825,0005.0911,3002.8932,700
95F3.824,0003.319,7003.127,000
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$2,080
Energy Cost-
10-Year Cost-
C&H 12K-Btu 23.1 SEER2 Mini Split Heat Pump (-13°F) Wifi, E-Star: 12.2 EER/11.5 HSPF (R454B)
$1,440 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F0.848000.848001.65,300
5F2.368,6001.861,9002.368,600
17F2.849,6002.633,5002.579,900
47F3.712,0005.224,1003.2714,400
95F3.5912,0004.482,6003.3213,700
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$1,440
Energy Cost-
10-Year Cost-
C&H 12K-Btu Slim Cassette 23 SEER2 Mini Split H-Heat Pump (-22°F) E-Star: 13 EER/10 HSPF (R454B)
$2,080 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F1.13,0001.13,0001.095,100
5F1.9911,5001.992,1001.9911,500
17F2.659,6002.662,9001.9511,900
47F3.5612,5003.744,6003.2315,200
95F3.8212,0007.824,0003.3113,900
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$2,080
Energy Cost-
10-Year Cost-
C&H 115v 12K-Btu 22.7 SEER2 Mini Split Heat Pump (-13°F) E-Star: 12.5 EER/10.4 HSPF (R410a)
$1,169 at MiniSplitWarehouse
COOPER&HUNTER R-410A
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
5F--1.842,0102.076,858
17F2.758,9001.742,3712.49,018
47F3.5212,0003.894,9103.0412,570
95F3.6612,0004.513,2313.5712,304
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$1,169
Energy Cost-
10-Year Cost-
C&H 18K-Btu 22.3 SEER2 Floor-Ceiling Mini Split Heat Pump (-13°F) E-Star: 12.5 EER/10.4 HSPF (R454B)
$2,199 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F0.791,1000.791,1001.698,400
5F2.0512,8001.683,1002.0512,800
17F2.5113,7002.114,4002.3815,100
47F3.318,0005.157,2003.2722,200
95F3.6618,0003.67,0003.3719,300
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$2,199
Energy Cost-
10-Year Cost-
C&H 24K-Btu 22.3 SEER2 Mini Split H-Heat Pump (-22°F) Wifi, E-Star: 12.5 EER/13.3 HSPF (R454B)
$2,350 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F0.932,2000.932,2001.3910,900
5F2.024,0001.912,2002.024,000
17F2.6121,6002.0414,5002.3323,400
47F3.0526,0005.0911,8003.228,100
95F3.6623,0003.316,8003.2524,500
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$2,350
Energy Cost-
10-Year Cost-
C&H 18K-Btu Slim Cassette 22.2 SEER2 Mini Split Heat Pump (-13°F) E-Star: 12.5 EER/12.2 HSPF (R454B)
$2,420 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F0.791,1000.791,1001.588,100
5F2.2513,1001.985,0002.2513,100
17F2.7714,0002.266,1002.4715,200
47F3.318,0005.577,6003.5522,800
95F3.6618,0002.614,0003.3218,800
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$2,420
Energy Cost-
10-Year Cost-
C&H 9K-Btu Slim Cassette 22.1 SEER2 Mini Split Heat Pump (-13°F) E-Star: 14.4 EER/11.8 HSPF (R454B)
$1,940 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F0.949000.949001.595,000
5F2.178,0002.061,9002.178,000
17F2.697,9002.932,8002.599,900
47F3.1911,0004.344,0003.214,300
95F4.259,0004.933,7003.3711,400
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$1,940
Energy Cost-
10-Year Cost-
C&H 12K-Btu Slim Cassette 22.1 SEER2 Mini Split Heat Pump (-13°F) E-Star: 12.3 EER/10 HSPF (R454B)
$1,970 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F1.151,1001.151,1001.655,000
5F2.478,6002.061,9002.478,600
17F2.778,6003.243,1002.5910,000
47F3.4112,0004.924,7003.4215,300
95F3.5912,0005.23,9003.4313,800
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$1,970
Energy Cost-
10-Year Cost-
C&H 6K-Btu 22 SEER2 Mini Split Slim Cassette Heat Pump (-22°F) 15 EER/12 HSPF (R454B)
$1,990 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F0.919000.919001.374,100
5F2.48,1002.061,9002.48,100
17F2.667,0002.492,8002.539,500
47F3.747,4003.743,7003.5511,500
95F4.436,5007.033,6003.8812,700
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$1,990
Energy Cost-
10-Year Cost-
C&H 18K-Btu 21.7 SEER2 Mini Split H-Heat Pump (-22°F) Wifi, E-Star: 13 EER/10.8 HSPF (R454B)
$2,090 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F1.724,0001.724,0001.439,600
5F2.018,0002.665,0002.018,000
17F2.7914,4003.367,0002.4919,800
47F3.5418,0004.6410,3003.7423,000
95F3.8218,0006.848,4003.1820,200
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$2,090
Energy Cost-
10-Year Cost-
C&H 9K-Btu 115v/110v 21.5 SEER2 Mini Split Cooling & Heating (5°F) E-Star: 12.5 EER/9 HSPF (R410a)
$839 at MiniSplitWarehouse
COOPER&HUNTER R-410A
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
5F--1.01,4001.926,601
17F2.466,8001.261,7242.128,044
47F2.9310,0003.294,0362.7311,186
95F3.669,0003.62,7002.7311,184
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$839
Energy Cost-
10-Year Cost-
C&H 6K-Btu 21.5 SEER2 115v-120v Mini Split AC Heat Pump (5°F) Wifi, E-Star: 12.5 EER/9 HSPF (R454B)
$1,179 at MiniSplitWarehouse
COOPER&HUNTER R454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
5F1.966,5001.592,5001.966,500
17F2.36,5001.993,4002.138,000
47F3.2910,0004.734,2003.1510,200
95F3.669,0005.372,2003.679,900
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$1,179
Energy Cost-
10-Year Cost-
C&H 9K-Btu 21.5 SEER2 115v Mini Split Heat Pump (5°F) Wifi, E-Star: 12.5 EER/9 HSPF (R454B)
$1,200 at MiniSplitWarehouse
COOPER&HUNTER R454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
5F1.966,5001.592,5001.966,500
17F2.36,5001.993,4002.138,000
47F3.2910,0004.734,2003.1510,200
95F3.669,0005.372,2003.679,900
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$1,200
Energy Cost-
10-Year Cost-
C&H 6K-Btu 21.4 SEER2 Ducted Slim Mini Split H-Heat Pump (-22F) E-Star 14.4 EER/13.8 HSPF (R454B)
$1,670 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F1.281,7001.281,7001.474,000
5F2.417,8001.582,3702.417,800
17F2.698,0002.063,3002.529,100
47F4.048,0004.523,7003.111,100
95F4.236,5005.173,0003.5311,800
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$1,670
Energy Cost-
10-Year Cost-
C&H 9K-Btu MS-Slim Ducted 21.4 SEER2 Mini Split H-Heat Pump (-22F) E-Star 13.4 EER/12.5 HSPF (R454B)
$1,740 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F1.351,8001.351,8001.286,400
5F1.8911,2001.62,4001.8911,200
17F2.499,6002.063,3001.9912,600
47F3.5310,0004.283,8003.2316,000
95F3.949,0005.053,1003.313,500
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$1,740
Energy Cost-
10-Year Cost-
Cooper Hunter 12K-Btu 21.3 SEER2 Mini Split Heat Pump AC (5°F) Wifi, 10.8 EER/9.1 HSPF (R454B)
$1,240 at MiniSplitWarehouse
COOPER&HUNTER R454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
5F1.918,0000.767001.918,000
17F2.418,7001.071,1002.169,200
47F3.1712,0003.113,5002.9113,400
95F3.1712,0003.561,7002.7813,300
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$1,240
Energy Cost-
10-Year Cost-
C&H 9K-Btu 21.2 SEER2 Mini Split Heat Pump (5°F) Wifi, E-Star: 12.6 EER/9.1 HSPF (R454B)
$1,200 at MiniSplitWarehouse
COOPER&HUNTER R454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
5F2.077,0001.071,1002.077,000
17F2.466,8001.741,9002.238,300
47F3.1910,0004.854,3003.111,100
95F3.719,0002.932,3003.559,700
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$1,200
Energy Cost-
10-Year Cost-
Cooper Hunter 12K-Btu 21.2 SEER2 115v Mini Split Heat Pump AC (5°F) Wifi, 10.1 EER/8.7 HSPF (R454B)
$1,240 at MiniSplitWarehouse
COOPER&HUNTER R454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
5F1.846,6001.732,3001.846,600
17F2.237,3002.113,1002.198,000
47F3.2912,0004.983,4002.9112,200
95F2.9612,0004.612,2003.012,300
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$1,240
Energy Cost-
10-Year Cost-
C&H 24K-Btu 21.1 SEER2 Floor-Ceiling Mini Split Heat Pump (-13°F) E-Star: 12.2 EER/11.1 HSPF (R454B)
$2,300 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F1.383,2001.383,2001.297,900
5F2.2718,6002.015,7002.2718,600
17F2.5620,0002.57,6002.3120,000
47F2.9924,4005.0911,8003.232,600
95F3.5724,0003.9711,1003.2629,000
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$2,300
Energy Cost-
10-Year Cost-
C&H 18K-Btu Slim Cassette 20.6 SEER2 Mini Split H-Heat Pump (-22°F) 12.5 EER/12.2 HSPF (R454B)
$2,570 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F0.764,0000.764,0001.479,500
5F1.8917,5001.793,3001.8917,500
17F2.514,5001.993,8002.0518,800
47F3.0120,0003.078,9003.2722,200
95F3.6516,7003.045,7003.2819,000
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$2,570
Energy Cost-
10-Year Cost-
C&H 18K-Btu 20 SEER2 Ceiling-Floor Mini Split H-Heat Pump (-22°F) E-Star: 12.5 EER/10.3 HSPF (R454B)
$2,350 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F0.791,1000.791,1001.338,400
5F1.8617,0001.64,8001.8617,000
17F2.5414,4002.37,6002.2420,200
47F3.0819,0004.598,3003.3220,700
95F3.6617,0004.347,4003.3719,200
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$2,350
Energy Cost-
10-Year Cost-
C&H 24K-Btu 20.4 SEER2 Ceiling-Floor Mini Split H-Heat Pump (-22°F) E-Star: 12 EER/12.1 HSPF (R454B)
$2,564 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F1.44,2001.44,2001.3310,500
5F2.1624,2001.614,9002.1624,200
17F2.7420,2002.527,9002.3823,300
47F3.3426,0005.2611,3003.3629,500
95F3.5222,0003.812,7003.2625,600
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$2,564
Energy Cost-
10-Year Cost-
C&H 12K-Btu MS-Slim Ducted 20 SEER2 Mini Split H-Heat Pump (-22F) E-Star 12 EER/10 HSPF (R454B)
$1,760 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F1.351,8001.351,8001.286,400
5F1.911,8001.62,4001.911,800
17F2.499,6002.063,3001.9913,100
47F3.3912,5004.283,8003.2716,200
95F3.5212,0005.053,1003.313,500
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$1,760
Energy Cost-
10-Year Cost-
C&H 18K-Btu MS-Slim Ducted 20 SEER2 Mini Split Heat Pump (-13°F) E-Star: 12.5 EER/10.5 HSPF (R454B)
$2,160 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F0.621,9000.621,9001.497,000
5F2.1914,0001.783,4002.1914,000
17F2.614,0002.264,4002.414,100
47F3.4720,0004.885,5003.4922,000
95F3.6617,0004.13,5003.1819,000
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$2,160
Energy Cost-
10-Year Cost-
C&H 16K-Btu 20 SEER2 Console Mini Split H-Heat Pump (-22°F) Wifi, E-Star: 12.5 EER/10.3 HSPF (R454B)
$2,250 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F0.764,0000.764,0001.217,600
5F1.9517,5001.675,0001.9517,500
17F2.614,2002.066,6002.1318,800
47F2.8517,0004.26,6003.1220,000
95F3.6616,0003.076,5003.1517,200
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$2,250
Energy Cost-
10-Year Cost-
C&H 36K-Btu 20 SEER2 Floor-Ceiling Mini Split Heat Pump (-13°F) 10.1 EER/10 HSPF (R454B)
$3,272 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F0.952,8000.952,8001.6820,400
5F2.1726,0002.116,4002.1726,000
17F2.6826,4002.88,8002.3630,900
47F3.3438,0004.8614,1003.3840,400
95F2.9636,0003.827,3002.7739,500
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$3,272
Energy Cost-
10-Year Cost-
C&H 36K-Btu 20 SEER2 Floor-Ceiling Mini Split H-Heat Pump (-22°F) E-Star: 12 EER/10.8 HSPF (R454B)
$4,034 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F1.345,2001.345,2001.5426,500
5F2.0239,5001.584,1002.0239,500
17F2.5830,2002.6914,4002.1642,400
47F3.2938,0004.7811,1003.2745,400
95F3.5236,4003.036,1003.1138,300
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$4,034
Energy Cost-
10-Year Cost-
C&H 48K-Btu 19.8 SEER2 (Floor-Ceiling) Mini Split Heat Pump (-13°F) E-Star 9.5 EER/10.2 HSPF (R454B)
$4,100 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F1.56,1001.56,1001.7227,900
5F1.9538,5002.319,6001.9538,500
17F2.439,5002.9112,6002.1345,100
47F2.8250,0008.1215,8002.9659,100
95F2.7948,0003.5710,1002.7850,000
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$4,100
Energy Cost-
10-Year Cost-
C&H 24K-Btu 19.7 SEER2 Central-AHU Mini Split Heat Pump (-13°F) E-Star: 11.7 EER/9 HSPF (R454B)
$2,666 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F0.823,3000.823,3001.8814,400
5F2.218,0001.745,4002.218,000
17F2.417,6001.985,0002.5523,200
47F3.5425,0004.155,8003.3633,800
95F3.4324,0003.336,7003.0529,600
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$2,666
Energy Cost-
10-Year Cost-
C&H 9K-Btu MS-Slim Ducted 19.5 SEER2 Mini Split Heat Pump (-13°F) E-Star: 12.8 EER/11 HSPF (R454B)
$1,620 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F1.121,3001.121,3001.745,700
5F2.258,6001.62,4002.258,600
17F2.618,9001.893,1002.459,600
47F3.6610,0004.223,6003.4514,000
95F3.779,0005.173,0003.3511,900
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$1,620
Energy Cost-
10-Year Cost-
Cooper Hunter 60K-Btu 19.5 SEER2 Floor-Ceiling Mini Split Heat Pump (-13°F) 9.5 EER/9.5 HSPF (R454B)
$4,415 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F1.596,3001.596,3001.5323,300
5F2.0135,0002.089,5002.0135,000
17F2.5337,2002.7112,5002.2245,300
47F3.0560,0005.1520,2003.0560,000
95F2.7954,0003.1415,0002.6454,500
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$4,415
Energy Cost-
10-Year Cost-
C&H 18K-Btu 19.2 SEER2 Mini Split Heat Pump AC (5°F) Wifi, 10.8 EER/9.6 HSPF (R454B)
$1,540 at MiniSplitWarehouse
COOPER&HUNTER R454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
5F2.1511,5001.22,0002.1511,500
17F2.6312,3002.033,6002.5814,800
47F3.0618,8004.786,2003.220,200
95F3.1618,0003.344,1003.2419,000
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$1,540
Energy Cost-
10-Year Cost-
C&H 12K-Btu MS-Slim Ducted 19 SEER2 Mini Split Heat Pump (-13°F) E-Star: 11.7 EER/10.2 HSPF (R454B)
$1,650 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F1.121,3001.121,3001.745,700
5F2.248,8001.62,4002.248,800
17F2.589,5001.893,1002.5810,300
47F3.4112,0004.173,7003.4915,600
95F3.4411,5005.173,0003.1513,000
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$1,650
Energy Cost-
10-Year Cost-
C&H 24K-Btu HS-Slim Ducted 19 SEER2 Mini Split Heat Pump (-13°F) E-Star: 12.5 EER/11 HSPF (R454B)
$2,469 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F1.272,9001.272,9001.7112,400
5F2.319,0001.884,5002.319,000
17F2.621,2002.155,5002.5621,600
47F3.6525,0004.546,5003.4335,100
95F3.6624,0003.285,6003.0628,300
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$2,469
Energy Cost-
10-Year Cost-
C&H 24K-Btu HS-Slim Ducted 19 SEER2 Mini Split H-Heat Pump (-22°F) E-Star: 12 EER/11.7 HSPF (R454B)
$2,728 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F1.294,0001.294,0001.2810,200
5F2.1824,0001.194,3002.1824,000
17F2.7121,6001.916,7002.4823,600
47F3.8126,0004.867,3003.7131,400
95F3.5224,0003.265,0003.428,000
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$2,728
Energy Cost-
10-Year Cost-
C&H 36K-Btu 16 SEER2 Ceiling/Floor Mini Split Heat Pump (5°F), 8 EER/10 HSPF (R410a)
$2,730 at MiniSplitWarehouse
COOPER&HUNTER R-410A
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F1.522,6001.522,6001.3116,000
5F--1.883,6001.822,000
17F2.223,0002.785,6002.1125,000
47F2.6838,0003.4811,4002.7546,500
95F2.4936,0003.769,1002.4536,400
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$2,730
Energy Cost-
10-Year Cost-
C&H 24K-Btu 18.7 SEER2 Mini Split Heat Pump AC (5°F) Wifi, 10 EER/9.3 HSPF (R454B)
$1,820 at MiniSplitWarehouse
COOPER&HUNTER R454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
5F2.1417,0001.193,2002.1417,000
17F2.5316,9002.045,7002.1818,700
47F3.324,0004.56,3002.9427,000
95F2.9324,0003.365,5002.7424,200
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$1,820
Energy Cost-
10-Year Cost-
C&H 24K-Btu 18.7 SEER2 Central-AHU Mini Split H-Heat Pump (-22°F) E-Star: 12 EER/10 HSPF (R454B)
$2,930 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F0.773,4000.773,4001.2810,500
5F2.123,6001.916,2002.123,600
17F2.416,9002.195,6002.3924,000
47F3.526,0006.298,8003.2729,000
95F3.5123,0007.857,5003.0427,000
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$2,930
Energy Cost-
10-Year Cost-
C&H 36K-Btu HS-Slim Ducted 18.7 SEER2 Mini Split Heat Pump (-13°F) 10.1 EER/10.2 HSPF (R454B)
$3,486 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F1.273,2001.273,2001.5917,400
5F2.125,6001.734,6002.125,600
17F2.7327,4002.266,1002.3931,000
47F3.740,0004.578,1003.7943,500
95F2.9636,0003.517,9002.9342,500
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$3,486
Energy Cost-
10-Year Cost-
C&H 18K-Btu 18.5 SEER2 Central-AHU Mini Split Heat Pump (-13°F) E-Star: 12.1 EER/9.8 HSPF (R454B)
$2,640 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F1.122,3001.122,3001.68,300
5F2.313,0001.943,7002.313,000
17F2.613,2002.324,2002.4814,800
47F3.5918,0004.885,5003.5521,800
95F3.5418,0003.495,6003.2320,400
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$2,640
Energy Cost-
10-Year Cost-
Cooper Hunter 48K-Btu 18.5 SEER2 Mini Split H-Heat Pump (-22°F) E-Star: 9.4 EER/10.1 HSPF (R454B)
$4,729 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F0.562,4000.562,4001.3922,700
5F1.8347,0002.018,7001.8347,000
17F2.3838,5002.7512,2002.2344,500
47F2.8652,0004.7918,8002.9258,700
95F2.7548,0002.696,7002.7253,500
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$4,729
Energy Cost-
10-Year Cost-
C&H 18K-Btu MS-Slim Ducted 18 SEER2 Mini Split H-Heat Pump (-22F) E-Star 12 EER/10.5 HSPF (R454B)
$2,310 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F1.222,2001.222,2001.519,000
5F2.018,0001.523,9002.018,000
17F2.715,0001.424,3002.2319,000
47F3.3719,0004.325,9002.8722,000
95F3.5117,0004.13,5003.1518,800
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$2,310
Energy Cost-
10-Year Cost-
C&H 18K-Btu 18 SEER2 Central-AHU Mini Split H-Heat Pump (-22°F) E-Star: 12 EER/10 HSPF (R454B)
$2,776 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F1.012,5501.012,5501.479,100
5F2.218,0002.25,8502.218,000
17F2.614,0002.325,5502.3819,800
47F3.6419,5004.885,0003.321,600
95F3.5218,0007.036,0003.1520,400
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$2,776
Energy Cost-
10-Year Cost-
Cooper Hunter 60K-Btu 18 SEER2 FC Mini Split Heat Pump (-22°F) E-Star: 9 EER/10.7 HSPF (R454B)
$5,480 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F0.572,3000.572,3001.4629,700
5F1.9154,0002.089,5001.9154,000
17F2.3341,0002.6912,4002.1758,000
47F3.0260,0005.1321,7003.265,500
95F2.6454,0002.9320,0002.6254,500
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$5,480
Energy Cost-
10-Year Cost-
C&H 36K-Btu HS-Slim Ducted 17.7 SEER2 Mini Split H-Heat Pump (-22°F) E-Star 12 EER/11.1 HSPF (R454B)
$4,248 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F1.013,8001.013,8001.422,200
5F2.137,6002.098,9002.137,600
17F2.7331,6002.3710,1002.2940,000
47F3.842,0004.7811,1003.4645,500
95F3.5236,0003.199,8002.9537,000
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$4,248
Energy Cost-
10-Year Cost-
C&H 48K-Btu 17.7 SEER2 Central Mini Split Heat Pump (-13°F) 10 EER/10 HSPF (R454B)
$4,419 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F0.542,0000.542,0001.4521,000
5F1.935,2001.515,1001.935,200
17F2.640,0002.097,7002.2841,000
47F3.550,0004.911,7003.2160,000
95F2.9348,0002.169,5002.7156,000
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$4,419
Energy Cost-
10-Year Cost-
C&H 36K-Btu 17.2 SEER2 Central-AHU Mini Split H-Heat Pump (-22°F) E-Star: 11.7 EER/9.5 HSPF (R454B)
$4,547 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F1.325,5001.325,5001.3923,800
5F2.0638,0001.653,6002.0638,000
17F2.228,0002.435,4002.1138,000
47F3.438,0003.49,4003.1745,000
95F3.4336,0002.535,7002.8136,400
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$4,547
Energy Cost-
10-Year Cost-
C&H 48K-Btu 17.1 SEER2 (HS-Slim Ducted) Mini Split Heat Pump (-13°F) 10 EER/9.8 HSPF (R454B)
$4,159 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F1.245,5001.245,5001.7127,800
5F2.038,0001.979,2002.038,000
17F2.4839,0002.1110,1002.3546,500
47F3.4950,0004.2111,2003.4860,500
95F2.9348,0003.4711,0002.8356,500
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$4,159
Energy Cost-
10-Year Cost-
C&H 60K-Btu HS-Slim Ducted 17 SEER2 Mini Split Heat Pump (-13°F) 10 EER/9.7 HSPF (R454B)
$4,731 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F1.336,2001.336,2001.6324,200
5F2.240,0002.0610,2002.240,000
17F2.6640,0002.1711,1002.4541,500
47F3.760,0004.4311,8003.867,000
95F2.9358,0003.5714,6002.7263,000
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$4,731
Energy Cost-
10-Year Cost-
C&H 48K-Btu 17 SEER2 Central Mini Split H-Heat Pump (-22°F) 10 EER/10.2 HSPF (R454B)
$5,039 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F0.331,0000.331,0001.3222,800
5F2.046,0000.431,6002.046,000
17F2.540,0001.445,4002.1642,000
47F3.550,0004.8212,0003.260,000
95F2.9348,0001.587,3002.655,500
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$5,039
Energy Cost-
10-Year Cost-
C&H 48K-Btu 16.7 SEER2 (HS-Slim Ducted) Mini Split H-Heat Pump (-22°F) 10.4 EER/10.8 HSPF (R454B)
$4,779 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F1.265,5001.265,5001.4424,800
5F2.047,5001.98,9002.047,500
17F2.6145,0001.9710,1002.445,500
47F3.652,0004.2611,2003.2760,000
95F3.0448,0003.4711,0002.7456,500
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$4,779
Energy Cost-
10-Year Cost-
Cooper & Hunter 60K-Btu 17 SEER2 Central Mini Split Heat Pump (5°F) 9.6 EER/8.5 HSPF (R410a)
$4,210 at MiniSplitWarehouse
COOPER&HUNTER R-410A
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F1.910,1001.910,1001.3922,000
5F1.934,5001.9110,3001.934,500
17F2.4837,8002.5111,8002.4837,800
47F3.460,0003.5515,5002.8360,400
95F2.8157,0003.0513,0002.8160,000
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$4,210
Energy Cost-
10-Year Cost-
C&H 60K-Btu 16 SEER2 Central-AHU Mini Split Heat Pump (-13°F) 9.5 EER/9.1 HSPF (R454B)
$4,732 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F1.3212,0001.3212,0001.2821,300
5F1.935,4002.219,1001.935,400
17F2.640,5002.7519,9002.241,500
47F3.4459,0004.4511,7003.3560,500
95F2.7855,0003.8521,8002.6857,500
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$4,732
Energy Cost-
10-Year Cost-
C&H 36K-Btu 15.8 SEER2 Central-AHU Mini Split Heat Pump (-13°F) 9 EER/9.3 HSPF (R454B)
$3,785 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F1.24,1001.24,1001.5217,400
5F1.9124,2000.892,1001.9124,200
17F2.425,0001.332,5002.1527,000
47F3.3638,0004.366,4003.342,500
95F2.6436,0003.398,9002.5838,000
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$3,785
Energy Cost-
10-Year Cost-
C&H 60K-Btu HS-Slim Ducted 15.8 SEER2 Mini Split H-Heat Pump (-22°F) 10.2 EER/10.4 HSPF (R454B)
$5,796 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F1.386,4001.386,4001.3829,800
5F2.153,5001.899,4002.153,500
17F2.7245,0002.010,3002.4152,000
47F3.7460,0004.111,2003.7666,000
95F2.9955,0003.5914,2002.8760,000
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$5,796
Energy Cost-
10-Year Cost-
C&H 36K-Btu 15.4 SEER2 Central Mini Split Heat Pump (5°F) 8.2 EER/9 HSPF (R410a)
$3,239 at MiniSplitWarehouse
COOPER&HUNTER R-410A
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-13.0F2.097,4002.097,4001.3715,000
5F2.0624,0002.17,6002.0624,000
17F2.5427,0002.68,7002.5327,200
47F3.138,0003.749,2002.9343,000
95F2.436,0003.199,8002.441,000
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$3,239
Energy Cost-
10-Year Cost-
C&H 60K-Btu 15.2 SEER2 Central-AHU Mini Split H-Heat Pump (-22°F) 10 EER/9.2 HSPF (R454B)
$5,781 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOP@ rated BTUCOP@ min BTUCOP@ max BTU
-22.0F1.119,1001.119,1001.4630,000
5F2.053,0002.219,1002.053,000
17F2.641,0002.2912,2002.251,500
47F3.3659,0003.779,9003.4566,500
95F2.9354,0002.8513,7002.5758,500
kWh Per Year, Just Heatpump-
kWh Backup Heat Needed-
kWh Total per Year-
Hours Over Capacity-
Hours Short Cycling-
Purchase Cost$5,781
Energy Cost-
10-Year Cost-

Compare all heat pumps