C&H 9K-Btu Console 27.2 SEER2 Mini Split H-Heat Pump (-22°F) E-Star: 15.1 EER/10.9 HSPF (R454B)
$1,680 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.04 | 2,700 | 1.04 | 2,700 | 1.02 | 4,700 |
| 5F | 1.84 | 11,300 | 1.83 | 2,000 | 1.84 | 11,300 |
| 17F | 2.71 | 9,800 | 2.49 | 2,800 | 2.17 | 12,200 |
| 47F | 4.4 | 9,000 | 4.96 | 4,400 | 3.5 | 16,100 |
| 95F | 4.4 | 9,000 | 5.71 | 3,700 | 3.49 | 13,700 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,680 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 9K-Btu 26 SEER2 Mini Split H-Heat Pump (-22°F) Wifi, E-Star: 15 EER/12.5 HSPF (R454B)
$1,520 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.07 | 2,000 | 1.07 | 2,000 | 1.24 | 5,800 |
| 5F | 1.8 | 11,500 | 1.8 | 4,000 | 1.8 | 11,500 |
| 17F | 2.59 | 10,000 | 2.34 | 5,200 | 1.75 | 12,800 |
| 47F | 3.63 | 12,000 | 5.57 | 3,800 | 3.3 | 16,000 |
| 95F | 4.4 | 9,000 | 8.79 | 3,600 | 3.35 | 13,500 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,520 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 9K-Btu Console 26 SEER2 Mini Split Heat Pump (-13°F) Wifi, E-Star: 16.2 EER/13.9 HSPF (R454B)
$1,560 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 0.84 | 800 | 0.84 | 800 | 1.42 | 4,600 |
| 5F | 2.27 | 8,600 | 1.78 | 1,700 | 2.27 | 8,600 |
| 17F | 2.9 | 9,000 | 3.35 | 3,200 | 2.49 | 9,600 |
| 47F | 4.32 | 9,000 | 5.54 | 5,100 | 3.38 | 12,700 |
| 95F | 4.71 | 9,000 | 5.86 | 4,000 | 3.86 | 12,900 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,560 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 12K-Btu 25 SEER2 Console Mini Split H-Heat Pump (-22°F) Wifi, E-Star: 12.5 EER/10.5 HSPF (R454B)
$1,710 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.1 | 3,000 | 1.1 | 3,000 | 1.04 | 4,800 |
| 5F | 1.88 | 11,300 | 1.99 | 2,100 | 1.88 | 11,300 |
| 17F | 2.71 | 9,800 | 2.66 | 2,900 | 2.14 | 12,400 |
| 47F | 3.86 | 12,000 | 4.96 | 4,400 | 3.5 | 16,100 |
| 95F | 3.66 | 12,000 | 5.71 | 3,700 | 3.57 | 14,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,710 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 9K-Btu 24.6 SEER2 Mini Split Heat Pump (-13°F) Wifi, E-Star: 14.7 EER/13 HSPF (R454B)
$1,400 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.76 | 4,200 | 1.76 | 4,200 | 1.53 | 5,000 |
| 5F | 2.33 | 8,200 | 2.11 | 3,600 | 2.33 | 8,200 |
| 17F | 2.8 | 8,600 | 2.47 | 3,800 | 2.47 | 10,200 |
| 47F | 3.66 | 10,000 | 5.35 | 4,200 | 3.36 | 14,200 |
| 95F | 4.32 | 9,000 | 4.33 | 3,100 | 3.9 | 10,900 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,400 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 12K-Btu 24.6 SEER2 Console Mini Split Heat Pump (-13°F) Wifi, E-Star: 12.7 EER/11 HSPF (R454B)
$1,610 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 0.81 | 800 | 0.81 | 800 | 1.42 | 4,600 |
| 5F | 2.51 | 8,900 | 1.78 | 1,700 | 2.51 | 8,900 |
| 17F | 2.87 | 9,000 | 3.35 | 3,200 | 2.49 | 9,600 |
| 47F | 3.91 | 12,000 | 5.54 | 5,100 | 3.15 | 12,900 |
| 95F | 3.74 | 12,000 | 5.86 | 4,000 | 3.37 | 13,100 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,610 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 12K-Btu 24 SEER2 Mini Split H-Heat Pump (-22°F) Wifi, E-Star: 13.2 EER/10.5 HSPF (R454B)
$1,540 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.07 | 2,000 | 1.07 | 2,000 | 1.25 | 5,900 |
| 5F | 1.8 | 11,500 | 1.8 | 4,000 | 1.8 | 11,500 |
| 17F | 2.59 | 10,000 | 2.34 | 5,200 | 1.75 | 12,800 |
| 47F | 3.63 | 12,000 | 4.84 | 3,800 | 3.35 | 16,000 |
| 95F | 3.86 | 12,000 | 8.79 | 3,600 | 3.35 | 13,500 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,540 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 18K-Btu 24 SEER2 Mini Split Heat Pump (-13°F) Wifi, E-Star: 13.5 EER/11.1 HSPF (R454B)
$1,940 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.32 | 2,300 | 1.32 | 2,300 | 1.7 | 8,200 |
| 5F | 2.35 | 13,000 | 2.03 | 3,600 | 2.35 | 13,000 |
| 17F | 2.59 | 13,000 | 2.5 | 4,700 | 2.43 | 15,000 |
| 47F | 3.82 | 18,000 | 5.43 | 7,600 | 3.68 | 22,000 |
| 95F | 3.97 | 18,000 | 3.01 | 3,600 | 3.45 | 20,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,940 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 9K-Btu Slim Cassette 24 SEER2 Mini Split H-Heat Pump (-22°F) E-Star: 14.6 EER/12.1 HSPF (R454B)
$2,060 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 0.56 | 900 | 0.56 | 900 | 1.1 | 5,100 |
| 5F | 1.83 | 10,600 | 1.85 | 4,100 | 1.83 | 10,600 |
| 17F | 2.44 | 9,000 | 2.17 | 5,100 | 2.0 | 11,900 |
| 47F | 3.71 | 10,900 | 3.71 | 3,800 | 3.02 | 13,900 |
| 95F | 4.25 | 9,000 | 7.82 | 4,000 | 3.29 | 12,900 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,060 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 16K-Btu 23.8 SEER2 Console Mini Split Heat Pump AC (-13°F) E-Star: 12.5 EER/13.5 HSPF (R454B)
$2,100 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 0.71 | 1,000 | 0.71 | 1,000 | 1.56 | 8,000 |
| 5F | 2.16 | 13,100 | 1.56 | 2,600 | 2.16 | 13,100 |
| 17F | 2.75 | 14,100 | 2.48 | 4,400 | 2.58 | 14,600 |
| 47F | 3.37 | 17,000 | 5.49 | 7,300 | 3.67 | 22,900 |
| 95F | 3.66 | 16,000 | 3.13 | 4,700 | 3.3 | 18,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,100 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Cooper & Hunter 6k-Btu 23.5 SEER Heat Pump Mini Split 220v AC (-22°F) (R410a)
$1,369 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-410A |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| 5F | 1.84 | 7,100 | 1.88 | 3,200 | 1.92 | 7,200 |
| 17F | 2.5 | 7,500 | 2.23 | 4,100 | 2.38 | 10,000 |
| 47F | 3.73 | 7,000 | 4.98 | 3,400 | 2.86 | 11,400 |
| 95F | 4.4 | 6,000 | 3.78 | 4,900 | 3.4 | 11,500 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,369 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 24K-Btu 23.5 SEER2 Mini Split Heat Pump (-13°F) Wifi, E-Star: 13 EER/10 HSPF (R454B)
$2,080 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.02 | 2,200 | 1.02 | 2,200 | 1.54 | 11,000 |
| 5F | 2.15 | 17,800 | 1.72 | 5,100 | 2.15 | 17,800 |
| 17F | 2.5 | 19,500 | 2.45 | 7,200 | 2.42 | 21,300 |
| 47F | 3.08 | 25,000 | 5.09 | 11,300 | 2.89 | 32,700 |
| 95F | 3.8 | 24,000 | 3.31 | 9,700 | 3.1 | 27,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,080 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 12K-Btu 23.1 SEER2 Mini Split Heat Pump (-13°F) Wifi, E-Star: 12.2 EER/11.5 HSPF (R454B)
$1,440 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 0.84 | 800 | 0.84 | 800 | 1.6 | 5,300 |
| 5F | 2.36 | 8,600 | 1.86 | 1,900 | 2.36 | 8,600 |
| 17F | 2.84 | 9,600 | 2.63 | 3,500 | 2.57 | 9,900 |
| 47F | 3.7 | 12,000 | 5.22 | 4,100 | 3.27 | 14,400 |
| 95F | 3.59 | 12,000 | 4.48 | 2,600 | 3.32 | 13,700 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,440 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 12K-Btu Slim Cassette 23 SEER2 Mini Split H-Heat Pump (-22°F) E-Star: 13 EER/10 HSPF (R454B)
$2,080 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.1 | 3,000 | 1.1 | 3,000 | 1.09 | 5,100 |
| 5F | 1.99 | 11,500 | 1.99 | 2,100 | 1.99 | 11,500 |
| 17F | 2.65 | 9,600 | 2.66 | 2,900 | 1.95 | 11,900 |
| 47F | 3.56 | 12,500 | 3.74 | 4,600 | 3.23 | 15,200 |
| 95F | 3.82 | 12,000 | 7.82 | 4,000 | 3.31 | 13,900 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,080 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 115v 12K-Btu 22.7 SEER2 Mini Split Heat Pump (-13°F) E-Star: 12.5 EER/10.4 HSPF (R410a)
$1,169 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-410A |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| 5F | - | - | 1.84 | 2,010 | 2.07 | 6,858 |
| 17F | 2.75 | 8,900 | 1.74 | 2,371 | 2.4 | 9,018 |
| 47F | 3.52 | 12,000 | 3.89 | 4,910 | 3.04 | 12,570 |
| 95F | 3.66 | 12,000 | 4.51 | 3,231 | 3.57 | 12,304 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,169 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 18K-Btu 22.3 SEER2 Floor-Ceiling Mini Split Heat Pump (-13°F) E-Star: 12.5 EER/10.4 HSPF (R454B)
$2,199 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 0.79 | 1,100 | 0.79 | 1,100 | 1.69 | 8,400 |
| 5F | 2.05 | 12,800 | 1.68 | 3,100 | 2.05 | 12,800 |
| 17F | 2.51 | 13,700 | 2.11 | 4,400 | 2.38 | 15,100 |
| 47F | 3.3 | 18,000 | 5.15 | 7,200 | 3.27 | 22,200 |
| 95F | 3.66 | 18,000 | 3.6 | 7,000 | 3.37 | 19,300 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,199 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 24K-Btu 22.3 SEER2 Mini Split H-Heat Pump (-22°F) Wifi, E-Star: 12.5 EER/13.3 HSPF (R454B)
$2,350 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 0.93 | 2,200 | 0.93 | 2,200 | 1.39 | 10,900 |
| 5F | 2.0 | 24,000 | 1.9 | 12,200 | 2.0 | 24,000 |
| 17F | 2.61 | 21,600 | 2.04 | 14,500 | 2.33 | 23,400 |
| 47F | 3.05 | 26,000 | 5.09 | 11,800 | 3.2 | 28,100 |
| 95F | 3.66 | 23,000 | 3.3 | 16,800 | 3.25 | 24,500 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,350 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 18K-Btu Slim Cassette 22.2 SEER2 Mini Split Heat Pump (-13°F) E-Star: 12.5 EER/12.2 HSPF (R454B)
$2,420 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 0.79 | 1,100 | 0.79 | 1,100 | 1.58 | 8,100 |
| 5F | 2.25 | 13,100 | 1.98 | 5,000 | 2.25 | 13,100 |
| 17F | 2.77 | 14,000 | 2.26 | 6,100 | 2.47 | 15,200 |
| 47F | 3.3 | 18,000 | 5.57 | 7,600 | 3.55 | 22,800 |
| 95F | 3.66 | 18,000 | 2.61 | 4,000 | 3.32 | 18,800 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,420 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 9K-Btu Slim Cassette 22.1 SEER2 Mini Split Heat Pump (-13°F) E-Star: 14.4 EER/11.8 HSPF (R454B)
$1,940 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 0.94 | 900 | 0.94 | 900 | 1.59 | 5,000 |
| 5F | 2.17 | 8,000 | 2.06 | 1,900 | 2.17 | 8,000 |
| 17F | 2.69 | 7,900 | 2.93 | 2,800 | 2.59 | 9,900 |
| 47F | 3.19 | 11,000 | 4.34 | 4,000 | 3.2 | 14,300 |
| 95F | 4.25 | 9,000 | 4.93 | 3,700 | 3.37 | 11,400 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,940 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 12K-Btu Slim Cassette 22.1 SEER2 Mini Split Heat Pump (-13°F) E-Star: 12.3 EER/10 HSPF (R454B)
$1,970 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.15 | 1,100 | 1.15 | 1,100 | 1.65 | 5,000 |
| 5F | 2.47 | 8,600 | 2.06 | 1,900 | 2.47 | 8,600 |
| 17F | 2.77 | 8,600 | 3.24 | 3,100 | 2.59 | 10,000 |
| 47F | 3.41 | 12,000 | 4.92 | 4,700 | 3.42 | 15,300 |
| 95F | 3.59 | 12,000 | 5.2 | 3,900 | 3.43 | 13,800 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,970 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 6K-Btu 22 SEER2 Mini Split Slim Cassette Heat Pump (-22°F) 15 EER/12 HSPF (R454B)
$1,990 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 0.91 | 900 | 0.91 | 900 | 1.37 | 4,100 |
| 5F | 2.4 | 8,100 | 2.06 | 1,900 | 2.4 | 8,100 |
| 17F | 2.66 | 7,000 | 2.49 | 2,800 | 2.53 | 9,500 |
| 47F | 3.74 | 7,400 | 3.74 | 3,700 | 3.55 | 11,500 |
| 95F | 4.43 | 6,500 | 7.03 | 3,600 | 3.88 | 12,700 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,990 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 18K-Btu 21.7 SEER2 Mini Split H-Heat Pump (-22°F) Wifi, E-Star: 13 EER/10.8 HSPF (R454B)
$2,090 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.72 | 4,000 | 1.72 | 4,000 | 1.43 | 9,600 |
| 5F | 2.0 | 18,000 | 2.66 | 5,000 | 2.0 | 18,000 |
| 17F | 2.79 | 14,400 | 3.36 | 7,000 | 2.49 | 19,800 |
| 47F | 3.54 | 18,000 | 4.64 | 10,300 | 3.74 | 23,000 |
| 95F | 3.82 | 18,000 | 6.84 | 8,400 | 3.18 | 20,200 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,090 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 9K-Btu 115v/110v 21.5 SEER2 Mini Split Cooling & Heating (5°F) E-Star: 12.5 EER/9 HSPF (R410a)
$839 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-410A |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| 5F | - | - | 1.0 | 1,400 | 1.92 | 6,601 |
| 17F | 2.46 | 6,800 | 1.26 | 1,724 | 2.12 | 8,044 |
| 47F | 2.93 | 10,000 | 3.29 | 4,036 | 2.73 | 11,186 |
| 95F | 3.66 | 9,000 | 3.6 | 2,700 | 2.73 | 11,184 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $839 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 6K-Btu 21.5 SEER2 115v-120v Mini Split AC Heat Pump (5°F) Wifi, E-Star: 12.5 EER/9 HSPF (R454B)
$1,179 at MiniSplitWarehouse
|
COOPER&HUNTER |
R454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| 5F | 1.96 | 6,500 | 1.59 | 2,500 | 1.96 | 6,500 |
| 17F | 2.3 | 6,500 | 1.99 | 3,400 | 2.13 | 8,000 |
| 47F | 3.29 | 10,000 | 4.73 | 4,200 | 3.15 | 10,200 |
| 95F | 3.66 | 9,000 | 5.37 | 2,200 | 3.67 | 9,900 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,179 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 9K-Btu 21.5 SEER2 115v Mini Split Heat Pump (5°F) Wifi, E-Star: 12.5 EER/9 HSPF (R454B)
$1,200 at MiniSplitWarehouse
|
COOPER&HUNTER |
R454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| 5F | 1.96 | 6,500 | 1.59 | 2,500 | 1.96 | 6,500 |
| 17F | 2.3 | 6,500 | 1.99 | 3,400 | 2.13 | 8,000 |
| 47F | 3.29 | 10,000 | 4.73 | 4,200 | 3.15 | 10,200 |
| 95F | 3.66 | 9,000 | 5.37 | 2,200 | 3.67 | 9,900 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,200 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 6K-Btu 21.4 SEER2 Ducted Slim Mini Split H-Heat Pump (-22F) E-Star 14.4 EER/13.8 HSPF (R454B)
$1,670 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.28 | 1,700 | 1.28 | 1,700 | 1.47 | 4,000 |
| 5F | 2.41 | 7,800 | 1.58 | 2,370 | 2.41 | 7,800 |
| 17F | 2.69 | 8,000 | 2.06 | 3,300 | 2.52 | 9,100 |
| 47F | 4.04 | 8,000 | 4.52 | 3,700 | 3.1 | 11,100 |
| 95F | 4.23 | 6,500 | 5.17 | 3,000 | 3.53 | 11,800 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,670 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 9K-Btu MS-Slim Ducted 21.4 SEER2 Mini Split H-Heat Pump (-22F) E-Star 13.4 EER/12.5 HSPF (R454B)
$1,740 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.35 | 1,800 | 1.35 | 1,800 | 1.28 | 6,400 |
| 5F | 1.89 | 11,200 | 1.6 | 2,400 | 1.89 | 11,200 |
| 17F | 2.49 | 9,600 | 2.06 | 3,300 | 1.99 | 12,600 |
| 47F | 3.53 | 10,000 | 4.28 | 3,800 | 3.23 | 16,000 |
| 95F | 3.94 | 9,000 | 5.05 | 3,100 | 3.3 | 13,500 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,740 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Cooper Hunter 12K-Btu 21.3 SEER2 Mini Split Heat Pump AC (5°F) Wifi, 10.8 EER/9.1 HSPF (R454B)
$1,240 at MiniSplitWarehouse
|
COOPER&HUNTER |
R454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| 5F | 1.91 | 8,000 | 0.76 | 700 | 1.91 | 8,000 |
| 17F | 2.41 | 8,700 | 1.07 | 1,100 | 2.16 | 9,200 |
| 47F | 3.17 | 12,000 | 3.11 | 3,500 | 2.91 | 13,400 |
| 95F | 3.17 | 12,000 | 3.56 | 1,700 | 2.78 | 13,300 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,240 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 9K-Btu 21.2 SEER2 Mini Split Heat Pump (5°F) Wifi, E-Star: 12.6 EER/9.1 HSPF (R454B)
$1,200 at MiniSplitWarehouse
|
COOPER&HUNTER |
R454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| 5F | 2.07 | 7,000 | 1.07 | 1,100 | 2.07 | 7,000 |
| 17F | 2.46 | 6,800 | 1.74 | 1,900 | 2.23 | 8,300 |
| 47F | 3.19 | 10,000 | 4.85 | 4,300 | 3.1 | 11,100 |
| 95F | 3.71 | 9,000 | 2.93 | 2,300 | 3.55 | 9,700 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,200 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Cooper Hunter 12K-Btu 21.2 SEER2 115v Mini Split Heat Pump AC (5°F) Wifi, 10.1 EER/8.7 HSPF (R454B)
$1,240 at MiniSplitWarehouse
|
COOPER&HUNTER |
R454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| 5F | 1.84 | 6,600 | 1.73 | 2,300 | 1.84 | 6,600 |
| 17F | 2.23 | 7,300 | 2.11 | 3,100 | 2.19 | 8,000 |
| 47F | 3.29 | 12,000 | 4.98 | 3,400 | 2.91 | 12,200 |
| 95F | 2.96 | 12,000 | 4.61 | 2,200 | 3.0 | 12,300 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,240 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 24K-Btu 21.1 SEER2 Floor-Ceiling Mini Split Heat Pump (-13°F) E-Star: 12.2 EER/11.1 HSPF (R454B)
$2,300 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.38 | 3,200 | 1.38 | 3,200 | 1.29 | 7,900 |
| 5F | 2.27 | 18,600 | 2.01 | 5,700 | 2.27 | 18,600 |
| 17F | 2.56 | 20,000 | 2.5 | 7,600 | 2.31 | 20,000 |
| 47F | 2.99 | 24,400 | 5.09 | 11,800 | 3.2 | 32,600 |
| 95F | 3.57 | 24,000 | 3.97 | 11,100 | 3.26 | 29,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,300 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 18K-Btu Slim Cassette 20.6 SEER2 Mini Split H-Heat Pump (-22°F) 12.5 EER/12.2 HSPF (R454B)
$2,570 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 0.76 | 4,000 | 0.76 | 4,000 | 1.47 | 9,500 |
| 5F | 1.89 | 17,500 | 1.79 | 3,300 | 1.89 | 17,500 |
| 17F | 2.5 | 14,500 | 1.99 | 3,800 | 2.05 | 18,800 |
| 47F | 3.01 | 20,000 | 3.07 | 8,900 | 3.27 | 22,200 |
| 95F | 3.65 | 16,700 | 3.04 | 5,700 | 3.28 | 19,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,570 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 18K-Btu 20 SEER2 Ceiling-Floor Mini Split H-Heat Pump (-22°F) E-Star: 12.5 EER/10.3 HSPF (R454B)
$2,350 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 0.79 | 1,100 | 0.79 | 1,100 | 1.33 | 8,400 |
| 5F | 1.86 | 17,000 | 1.6 | 4,800 | 1.86 | 17,000 |
| 17F | 2.54 | 14,400 | 2.3 | 7,600 | 2.24 | 20,200 |
| 47F | 3.08 | 19,000 | 4.59 | 8,300 | 3.32 | 20,700 |
| 95F | 3.66 | 17,000 | 4.34 | 7,400 | 3.37 | 19,200 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,350 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 24K-Btu 20.4 SEER2 Ceiling-Floor Mini Split H-Heat Pump (-22°F) E-Star: 12 EER/12.1 HSPF (R454B)
$2,564 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.4 | 4,200 | 1.4 | 4,200 | 1.33 | 10,500 |
| 5F | 2.16 | 24,200 | 1.61 | 4,900 | 2.16 | 24,200 |
| 17F | 2.74 | 20,200 | 2.52 | 7,900 | 2.38 | 23,300 |
| 47F | 3.34 | 26,000 | 5.26 | 11,300 | 3.36 | 29,500 |
| 95F | 3.52 | 22,000 | 3.8 | 12,700 | 3.26 | 25,600 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,564 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 12K-Btu MS-Slim Ducted 20 SEER2 Mini Split H-Heat Pump (-22F) E-Star 12 EER/10 HSPF (R454B)
$1,760 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.35 | 1,800 | 1.35 | 1,800 | 1.28 | 6,400 |
| 5F | 1.9 | 11,800 | 1.6 | 2,400 | 1.9 | 11,800 |
| 17F | 2.49 | 9,600 | 2.06 | 3,300 | 1.99 | 13,100 |
| 47F | 3.39 | 12,500 | 4.28 | 3,800 | 3.27 | 16,200 |
| 95F | 3.52 | 12,000 | 5.05 | 3,100 | 3.3 | 13,500 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,760 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 18K-Btu MS-Slim Ducted 20 SEER2 Mini Split Heat Pump (-13°F) E-Star: 12.5 EER/10.5 HSPF (R454B)
$2,160 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 0.62 | 1,900 | 0.62 | 1,900 | 1.49 | 7,000 |
| 5F | 2.19 | 14,000 | 1.78 | 3,400 | 2.19 | 14,000 |
| 17F | 2.6 | 14,000 | 2.26 | 4,400 | 2.4 | 14,100 |
| 47F | 3.47 | 20,000 | 4.88 | 5,500 | 3.49 | 22,000 |
| 95F | 3.66 | 17,000 | 4.1 | 3,500 | 3.18 | 19,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,160 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 16K-Btu 20 SEER2 Console Mini Split H-Heat Pump (-22°F) Wifi, E-Star: 12.5 EER/10.3 HSPF (R454B)
$2,250 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 0.76 | 4,000 | 0.76 | 4,000 | 1.21 | 7,600 |
| 5F | 1.95 | 17,500 | 1.67 | 5,000 | 1.95 | 17,500 |
| 17F | 2.6 | 14,200 | 2.06 | 6,600 | 2.13 | 18,800 |
| 47F | 2.85 | 17,000 | 4.2 | 6,600 | 3.12 | 20,000 |
| 95F | 3.66 | 16,000 | 3.07 | 6,500 | 3.15 | 17,200 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,250 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 36K-Btu 20 SEER2 Floor-Ceiling Mini Split Heat Pump (-13°F) 10.1 EER/10 HSPF (R454B)
$3,272 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 0.95 | 2,800 | 0.95 | 2,800 | 1.68 | 20,400 |
| 5F | 2.17 | 26,000 | 2.11 | 6,400 | 2.17 | 26,000 |
| 17F | 2.68 | 26,400 | 2.8 | 8,800 | 2.36 | 30,900 |
| 47F | 3.34 | 38,000 | 4.86 | 14,100 | 3.38 | 40,400 |
| 95F | 2.96 | 36,000 | 3.82 | 7,300 | 2.77 | 39,500 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $3,272 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 36K-Btu 20 SEER2 Floor-Ceiling Mini Split H-Heat Pump (-22°F) E-Star: 12 EER/10.8 HSPF (R454B)
$4,034 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.34 | 5,200 | 1.34 | 5,200 | 1.54 | 26,500 |
| 5F | 2.02 | 39,500 | 1.58 | 4,100 | 2.02 | 39,500 |
| 17F | 2.58 | 30,200 | 2.69 | 14,400 | 2.16 | 42,400 |
| 47F | 3.29 | 38,000 | 4.78 | 11,100 | 3.27 | 45,400 |
| 95F | 3.52 | 36,400 | 3.03 | 6,100 | 3.11 | 38,300 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $4,034 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 48K-Btu 19.8 SEER2 (Floor-Ceiling) Mini Split Heat Pump (-13°F) E-Star 9.5 EER/10.2 HSPF (R454B)
$4,100 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.5 | 6,100 | 1.5 | 6,100 | 1.72 | 27,900 |
| 5F | 1.95 | 38,500 | 2.31 | 9,600 | 1.95 | 38,500 |
| 17F | 2.4 | 39,500 | 2.91 | 12,600 | 2.13 | 45,100 |
| 47F | 2.82 | 50,000 | 8.12 | 15,800 | 2.96 | 59,100 |
| 95F | 2.79 | 48,000 | 3.57 | 10,100 | 2.78 | 50,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $4,100 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 24K-Btu 19.7 SEER2 Central-AHU Mini Split Heat Pump (-13°F) E-Star: 11.7 EER/9 HSPF (R454B)
$2,666 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 0.82 | 3,300 | 0.82 | 3,300 | 1.88 | 14,400 |
| 5F | 2.2 | 18,000 | 1.74 | 5,400 | 2.2 | 18,000 |
| 17F | 2.4 | 17,600 | 1.98 | 5,000 | 2.55 | 23,200 |
| 47F | 3.54 | 25,000 | 4.15 | 5,800 | 3.36 | 33,800 |
| 95F | 3.43 | 24,000 | 3.33 | 6,700 | 3.05 | 29,600 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,666 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 9K-Btu MS-Slim Ducted 19.5 SEER2 Mini Split Heat Pump (-13°F) E-Star: 12.8 EER/11 HSPF (R454B)
$1,620 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.12 | 1,300 | 1.12 | 1,300 | 1.74 | 5,700 |
| 5F | 2.25 | 8,600 | 1.6 | 2,400 | 2.25 | 8,600 |
| 17F | 2.61 | 8,900 | 1.89 | 3,100 | 2.45 | 9,600 |
| 47F | 3.66 | 10,000 | 4.22 | 3,600 | 3.45 | 14,000 |
| 95F | 3.77 | 9,000 | 5.17 | 3,000 | 3.35 | 11,900 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,620 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Cooper Hunter 60K-Btu 19.5 SEER2 Floor-Ceiling Mini Split Heat Pump (-13°F) 9.5 EER/9.5 HSPF (R454B)
$4,415 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.59 | 6,300 | 1.59 | 6,300 | 1.53 | 23,300 |
| 5F | 2.01 | 35,000 | 2.08 | 9,500 | 2.01 | 35,000 |
| 17F | 2.53 | 37,200 | 2.71 | 12,500 | 2.22 | 45,300 |
| 47F | 3.05 | 60,000 | 5.15 | 20,200 | 3.05 | 60,000 |
| 95F | 2.79 | 54,000 | 3.14 | 15,000 | 2.64 | 54,500 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $4,415 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 18K-Btu 19.2 SEER2 Mini Split Heat Pump AC (5°F) Wifi, 10.8 EER/9.6 HSPF (R454B)
$1,540 at MiniSplitWarehouse
|
COOPER&HUNTER |
R454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| 5F | 2.15 | 11,500 | 1.2 | 2,000 | 2.15 | 11,500 |
| 17F | 2.63 | 12,300 | 2.03 | 3,600 | 2.58 | 14,800 |
| 47F | 3.06 | 18,800 | 4.78 | 6,200 | 3.2 | 20,200 |
| 95F | 3.16 | 18,000 | 3.34 | 4,100 | 3.24 | 19,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,540 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 12K-Btu MS-Slim Ducted 19 SEER2 Mini Split Heat Pump (-13°F) E-Star: 11.7 EER/10.2 HSPF (R454B)
$1,650 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.12 | 1,300 | 1.12 | 1,300 | 1.74 | 5,700 |
| 5F | 2.24 | 8,800 | 1.6 | 2,400 | 2.24 | 8,800 |
| 17F | 2.58 | 9,500 | 1.89 | 3,100 | 2.58 | 10,300 |
| 47F | 3.41 | 12,000 | 4.17 | 3,700 | 3.49 | 15,600 |
| 95F | 3.44 | 11,500 | 5.17 | 3,000 | 3.15 | 13,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,650 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 24K-Btu HS-Slim Ducted 19 SEER2 Mini Split Heat Pump (-13°F) E-Star: 12.5 EER/11 HSPF (R454B)
$2,469 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.27 | 2,900 | 1.27 | 2,900 | 1.71 | 12,400 |
| 5F | 2.3 | 19,000 | 1.88 | 4,500 | 2.3 | 19,000 |
| 17F | 2.6 | 21,200 | 2.15 | 5,500 | 2.56 | 21,600 |
| 47F | 3.65 | 25,000 | 4.54 | 6,500 | 3.43 | 35,100 |
| 95F | 3.66 | 24,000 | 3.28 | 5,600 | 3.06 | 28,300 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,469 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 24K-Btu HS-Slim Ducted 19 SEER2 Mini Split H-Heat Pump (-22°F) E-Star: 12 EER/11.7 HSPF (R454B)
$2,728 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.29 | 4,000 | 1.29 | 4,000 | 1.28 | 10,200 |
| 5F | 2.18 | 24,000 | 1.19 | 4,300 | 2.18 | 24,000 |
| 17F | 2.71 | 21,600 | 1.91 | 6,700 | 2.48 | 23,600 |
| 47F | 3.81 | 26,000 | 4.86 | 7,300 | 3.71 | 31,400 |
| 95F | 3.52 | 24,000 | 3.26 | 5,000 | 3.4 | 28,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,728 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 36K-Btu 16 SEER2 Ceiling/Floor Mini Split Heat Pump (5°F), 8 EER/10 HSPF (R410a)
$2,730 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-410A |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.52 | 2,600 | 1.52 | 2,600 | 1.31 | 16,000 |
| 5F | - | - | 1.88 | 3,600 | 1.8 | 22,000 |
| 17F | 2.2 | 23,000 | 2.78 | 5,600 | 2.11 | 25,000 |
| 47F | 2.68 | 38,000 | 3.48 | 11,400 | 2.75 | 46,500 |
| 95F | 2.49 | 36,000 | 3.76 | 9,100 | 2.45 | 36,400 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,730 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 24K-Btu 18.7 SEER2 Mini Split Heat Pump AC (5°F) Wifi, 10 EER/9.3 HSPF (R454B)
$1,820 at MiniSplitWarehouse
|
COOPER&HUNTER |
R454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| 5F | 2.14 | 17,000 | 1.19 | 3,200 | 2.14 | 17,000 |
| 17F | 2.53 | 16,900 | 2.04 | 5,700 | 2.18 | 18,700 |
| 47F | 3.3 | 24,000 | 4.5 | 6,300 | 2.94 | 27,000 |
| 95F | 2.93 | 24,000 | 3.36 | 5,500 | 2.74 | 24,200 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,820 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 24K-Btu 18.7 SEER2 Central-AHU Mini Split H-Heat Pump (-22°F) E-Star: 12 EER/10 HSPF (R454B)
$2,930 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 0.77 | 3,400 | 0.77 | 3,400 | 1.28 | 10,500 |
| 5F | 2.1 | 23,600 | 1.91 | 6,200 | 2.1 | 23,600 |
| 17F | 2.4 | 16,900 | 2.19 | 5,600 | 2.39 | 24,000 |
| 47F | 3.5 | 26,000 | 6.29 | 8,800 | 3.27 | 29,000 |
| 95F | 3.51 | 23,000 | 7.85 | 7,500 | 3.04 | 27,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,930 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 36K-Btu HS-Slim Ducted 18.7 SEER2 Mini Split Heat Pump (-13°F) 10.1 EER/10.2 HSPF (R454B)
$3,486 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.27 | 3,200 | 1.27 | 3,200 | 1.59 | 17,400 |
| 5F | 2.1 | 25,600 | 1.73 | 4,600 | 2.1 | 25,600 |
| 17F | 2.73 | 27,400 | 2.26 | 6,100 | 2.39 | 31,000 |
| 47F | 3.7 | 40,000 | 4.57 | 8,100 | 3.79 | 43,500 |
| 95F | 2.96 | 36,000 | 3.51 | 7,900 | 2.93 | 42,500 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $3,486 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 18K-Btu 18.5 SEER2 Central-AHU Mini Split Heat Pump (-13°F) E-Star: 12.1 EER/9.8 HSPF (R454B)
$2,640 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.12 | 2,300 | 1.12 | 2,300 | 1.6 | 8,300 |
| 5F | 2.3 | 13,000 | 1.94 | 3,700 | 2.3 | 13,000 |
| 17F | 2.6 | 13,200 | 2.32 | 4,200 | 2.48 | 14,800 |
| 47F | 3.59 | 18,000 | 4.88 | 5,500 | 3.55 | 21,800 |
| 95F | 3.54 | 18,000 | 3.49 | 5,600 | 3.23 | 20,400 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,640 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Cooper Hunter 48K-Btu 18.5 SEER2 Mini Split H-Heat Pump (-22°F) E-Star: 9.4 EER/10.1 HSPF (R454B)
$4,729 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 0.56 | 2,400 | 0.56 | 2,400 | 1.39 | 22,700 |
| 5F | 1.83 | 47,000 | 2.01 | 8,700 | 1.83 | 47,000 |
| 17F | 2.38 | 38,500 | 2.75 | 12,200 | 2.23 | 44,500 |
| 47F | 2.86 | 52,000 | 4.79 | 18,800 | 2.92 | 58,700 |
| 95F | 2.75 | 48,000 | 2.69 | 6,700 | 2.72 | 53,500 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $4,729 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 18K-Btu MS-Slim Ducted 18 SEER2 Mini Split H-Heat Pump (-22F) E-Star 12 EER/10.5 HSPF (R454B)
$2,310 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.22 | 2,200 | 1.22 | 2,200 | 1.51 | 9,000 |
| 5F | 2.0 | 18,000 | 1.52 | 3,900 | 2.0 | 18,000 |
| 17F | 2.7 | 15,000 | 1.42 | 4,300 | 2.23 | 19,000 |
| 47F | 3.37 | 19,000 | 4.32 | 5,900 | 2.87 | 22,000 |
| 95F | 3.51 | 17,000 | 4.1 | 3,500 | 3.15 | 18,800 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,310 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 18K-Btu 18 SEER2 Central-AHU Mini Split H-Heat Pump (-22°F) E-Star: 12 EER/10 HSPF (R454B)
$2,776 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.01 | 2,550 | 1.01 | 2,550 | 1.47 | 9,100 |
| 5F | 2.2 | 18,000 | 2.2 | 5,850 | 2.2 | 18,000 |
| 17F | 2.6 | 14,000 | 2.32 | 5,550 | 2.38 | 19,800 |
| 47F | 3.64 | 19,500 | 4.88 | 5,000 | 3.3 | 21,600 |
| 95F | 3.52 | 18,000 | 7.03 | 6,000 | 3.15 | 20,400 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,776 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Cooper Hunter 60K-Btu 18 SEER2 FC Mini Split Heat Pump (-22°F) E-Star: 9 EER/10.7 HSPF (R454B)
$5,480 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 0.57 | 2,300 | 0.57 | 2,300 | 1.46 | 29,700 |
| 5F | 1.91 | 54,000 | 2.08 | 9,500 | 1.91 | 54,000 |
| 17F | 2.33 | 41,000 | 2.69 | 12,400 | 2.17 | 58,000 |
| 47F | 3.02 | 60,000 | 5.13 | 21,700 | 3.2 | 65,500 |
| 95F | 2.64 | 54,000 | 2.93 | 20,000 | 2.62 | 54,500 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $5,480 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 36K-Btu HS-Slim Ducted 17.7 SEER2 Mini Split H-Heat Pump (-22°F) E-Star 12 EER/11.1 HSPF (R454B)
$4,248 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.01 | 3,800 | 1.01 | 3,800 | 1.4 | 22,200 |
| 5F | 2.1 | 37,600 | 2.09 | 8,900 | 2.1 | 37,600 |
| 17F | 2.73 | 31,600 | 2.37 | 10,100 | 2.29 | 40,000 |
| 47F | 3.8 | 42,000 | 4.78 | 11,100 | 3.46 | 45,500 |
| 95F | 3.52 | 36,000 | 3.19 | 9,800 | 2.95 | 37,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $4,248 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 48K-Btu 17.7 SEER2 Central Mini Split Heat Pump (-13°F) 10 EER/10 HSPF (R454B)
$4,419 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 0.54 | 2,000 | 0.54 | 2,000 | 1.45 | 21,000 |
| 5F | 1.9 | 35,200 | 1.51 | 5,100 | 1.9 | 35,200 |
| 17F | 2.6 | 40,000 | 2.09 | 7,700 | 2.28 | 41,000 |
| 47F | 3.5 | 50,000 | 4.9 | 11,700 | 3.21 | 60,000 |
| 95F | 2.93 | 48,000 | 2.16 | 9,500 | 2.71 | 56,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $4,419 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 36K-Btu 17.2 SEER2 Central-AHU Mini Split H-Heat Pump (-22°F) E-Star: 11.7 EER/9.5 HSPF (R454B)
$4,547 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.32 | 5,500 | 1.32 | 5,500 | 1.39 | 23,800 |
| 5F | 2.06 | 38,000 | 1.65 | 3,600 | 2.06 | 38,000 |
| 17F | 2.2 | 28,000 | 2.43 | 5,400 | 2.11 | 38,000 |
| 47F | 3.4 | 38,000 | 3.4 | 9,400 | 3.17 | 45,000 |
| 95F | 3.43 | 36,000 | 2.53 | 5,700 | 2.81 | 36,400 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $4,547 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 48K-Btu 17.1 SEER2 (HS-Slim Ducted) Mini Split Heat Pump (-13°F) 10 EER/9.8 HSPF (R454B)
$4,159 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.24 | 5,500 | 1.24 | 5,500 | 1.71 | 27,800 |
| 5F | 2.0 | 38,000 | 1.97 | 9,200 | 2.0 | 38,000 |
| 17F | 2.48 | 39,000 | 2.11 | 10,100 | 2.35 | 46,500 |
| 47F | 3.49 | 50,000 | 4.21 | 11,200 | 3.48 | 60,500 |
| 95F | 2.93 | 48,000 | 3.47 | 11,000 | 2.83 | 56,500 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $4,159 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 60K-Btu HS-Slim Ducted 17 SEER2 Mini Split Heat Pump (-13°F) 10 EER/9.7 HSPF (R454B)
$4,731 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.33 | 6,200 | 1.33 | 6,200 | 1.63 | 24,200 |
| 5F | 2.2 | 40,000 | 2.06 | 10,200 | 2.2 | 40,000 |
| 17F | 2.66 | 40,000 | 2.17 | 11,100 | 2.45 | 41,500 |
| 47F | 3.7 | 60,000 | 4.43 | 11,800 | 3.8 | 67,000 |
| 95F | 2.93 | 58,000 | 3.57 | 14,600 | 2.72 | 63,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $4,731 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 48K-Btu 17 SEER2 Central Mini Split H-Heat Pump (-22°F) 10 EER/10.2 HSPF (R454B)
$5,039 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 0.33 | 1,000 | 0.33 | 1,000 | 1.32 | 22,800 |
| 5F | 2.0 | 46,000 | 0.43 | 1,600 | 2.0 | 46,000 |
| 17F | 2.5 | 40,000 | 1.44 | 5,400 | 2.16 | 42,000 |
| 47F | 3.5 | 50,000 | 4.82 | 12,000 | 3.2 | 60,000 |
| 95F | 2.93 | 48,000 | 1.58 | 7,300 | 2.6 | 55,500 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $5,039 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 48K-Btu 16.7 SEER2 (HS-Slim Ducted) Mini Split H-Heat Pump (-22°F) 10.4 EER/10.8 HSPF (R454B)
$4,779 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.26 | 5,500 | 1.26 | 5,500 | 1.44 | 24,800 |
| 5F | 2.0 | 47,500 | 1.9 | 8,900 | 2.0 | 47,500 |
| 17F | 2.61 | 45,000 | 1.97 | 10,100 | 2.4 | 45,500 |
| 47F | 3.6 | 52,000 | 4.26 | 11,200 | 3.27 | 60,000 |
| 95F | 3.04 | 48,000 | 3.47 | 11,000 | 2.74 | 56,500 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $4,779 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Cooper & Hunter 60K-Btu 17 SEER2 Central Mini Split Heat Pump (5°F) 9.6 EER/8.5 HSPF (R410a)
$4,210 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-410A |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.9 | 10,100 | 1.9 | 10,100 | 1.39 | 22,000 |
| 5F | 1.9 | 34,500 | 1.91 | 10,300 | 1.9 | 34,500 |
| 17F | 2.48 | 37,800 | 2.51 | 11,800 | 2.48 | 37,800 |
| 47F | 3.4 | 60,000 | 3.55 | 15,500 | 2.83 | 60,400 |
| 95F | 2.81 | 57,000 | 3.05 | 13,000 | 2.81 | 60,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $4,210 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 60K-Btu 16 SEER2 Central-AHU Mini Split Heat Pump (-13°F) 9.5 EER/9.1 HSPF (R454B)
$4,732 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.32 | 12,000 | 1.32 | 12,000 | 1.28 | 21,300 |
| 5F | 1.9 | 35,400 | 2.2 | 19,100 | 1.9 | 35,400 |
| 17F | 2.6 | 40,500 | 2.75 | 19,900 | 2.2 | 41,500 |
| 47F | 3.44 | 59,000 | 4.45 | 11,700 | 3.35 | 60,500 |
| 95F | 2.78 | 55,000 | 3.85 | 21,800 | 2.68 | 57,500 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $4,732 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 36K-Btu 15.8 SEER2 Central-AHU Mini Split Heat Pump (-13°F) 9 EER/9.3 HSPF (R454B)
$3,785 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.2 | 4,100 | 1.2 | 4,100 | 1.52 | 17,400 |
| 5F | 1.91 | 24,200 | 0.89 | 2,100 | 1.91 | 24,200 |
| 17F | 2.4 | 25,000 | 1.33 | 2,500 | 2.15 | 27,000 |
| 47F | 3.36 | 38,000 | 4.36 | 6,400 | 3.3 | 42,500 |
| 95F | 2.64 | 36,000 | 3.39 | 8,900 | 2.58 | 38,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $3,785 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 60K-Btu HS-Slim Ducted 15.8 SEER2 Mini Split H-Heat Pump (-22°F) 10.2 EER/10.4 HSPF (R454B)
$5,796 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.38 | 6,400 | 1.38 | 6,400 | 1.38 | 29,800 |
| 5F | 2.1 | 53,500 | 1.89 | 9,400 | 2.1 | 53,500 |
| 17F | 2.72 | 45,000 | 2.0 | 10,300 | 2.41 | 52,000 |
| 47F | 3.74 | 60,000 | 4.1 | 11,200 | 3.76 | 66,000 |
| 95F | 2.99 | 55,000 | 3.59 | 14,200 | 2.87 | 60,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $5,796 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 36K-Btu 15.4 SEER2 Central Mini Split Heat Pump (5°F) 8.2 EER/9 HSPF (R410a)
$3,239 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-410A |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 2.09 | 7,400 | 2.09 | 7,400 | 1.37 | 15,000 |
| 5F | 2.06 | 24,000 | 2.1 | 7,600 | 2.06 | 24,000 |
| 17F | 2.54 | 27,000 | 2.6 | 8,700 | 2.53 | 27,200 |
| 47F | 3.1 | 38,000 | 3.74 | 9,200 | 2.93 | 43,000 |
| 95F | 2.4 | 36,000 | 3.19 | 9,800 | 2.4 | 41,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $3,239 |
| Energy Cost | - |
| 10-Year Cost | - |
|
C&H 60K-Btu 15.2 SEER2 Central-AHU Mini Split H-Heat Pump (-22°F) 10 EER/9.2 HSPF (R454B)
$5,781 at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.11 | 9,100 | 1.11 | 9,100 | 1.46 | 30,000 |
| 5F | 2.0 | 53,000 | 2.2 | 19,100 | 2.0 | 53,000 |
| 17F | 2.6 | 41,000 | 2.29 | 12,200 | 2.2 | 51,500 |
| 47F | 3.36 | 59,000 | 3.77 | 9,900 | 3.45 | 66,500 |
| 95F | 2.93 | 54,000 | 2.85 | 13,700 | 2.57 | 58,500 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $5,781 |
| Energy Cost | - |
| 10-Year Cost | - |
|