Durastar DRAS09F2A & DRA1H09S2A 9,000 BTU 27.2 SEER2 Floor Mounted Sirius Heat Heat Pump System - R454B
$2,305 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.04 | 2,700 | 1.04 | 2,700 | 1.02 | 4,700 |
| 5F | 1.84 | 11,300 | 1.83 | 2,000 | 1.84 | 11,300 |
| 17F | 2.71 | 9,800 | 2.49 | 2,800 | 2.17 | 12,200 |
| 47F | 4.4 | 9,000 | 4.96 | 4,400 | 3.5 | 16,100 |
| 95F | 4.4 | 9,000 | 5.71 | 3,700 | 3.49 | 13,700 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,305 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAW09F2A & DRA1H09S2A 9,000 BTU 26.0 SEER2 Wall Mounted Sirius Heat Heat Pump System - R454B
$1,594 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.07 | 2,000 | 1.07 | 2,000 | 1.24 | 5,800 |
| 5F | 1.8 | 11,500 | 1.8 | 4,000 | 1.8 | 11,500 |
| 17F | 2.59 | 10,000 | 2.34 | 5,200 | 1.75 | 12,800 |
| 47F | 3.63 | 12,000 | 5.57 | 3,800 | 3.3 | 16,000 |
| 95F | 4.4 | 9,000 | 8.79 | 3,600 | 3.35 | 13,500 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,594 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAS09F2A & DRA1U09S2A 9,000 BTU 26.0 SEER2 Floor Mounted Heat Pump System - R454B
$1,831 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 0.84 | 800 | 0.84 | 800 | 1.42 | 4,600 |
| 5F | 2.27 | 8,600 | 1.78 | 1,700 | 2.27 | 8,600 |
| 17F | 2.9 | 9,000 | 3.35 | 3,200 | 2.49 | 9,600 |
| 47F | 4.32 | 9,000 | 5.54 | 5,100 | 3.38 | 12,700 |
| 95F | 4.71 | 9,000 | 5.86 | 4,000 | 3.86 | 12,900 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,831 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAW06F2A & DRA1H06S2A 6,000 BTU 25.3 SEER2 Wall Mounted Sirius Heat Heat Pump System - R454B
$1,126 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.09 | 2,300 | 1.09 | 2,300 | 1.22 | 3,900 |
| 5F | 2.29 | 7,500 | 1.65 | 3,100 | 2.29 | 7,500 |
| 17F | 2.5 | 7,600 | 2.1 | 3,800 | 2.04 | 8,700 |
| 47F | 3.8 | 7,000 | 4.94 | 3,200 | 2.61 | 10,700 |
| 95F | 4.63 | 6,000 | 4.88 | 2,500 | 3.62 | 11,500 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,126 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAS12F2A & DRA1H12S2A 12,000 BTU 25.0 SEER2 Floor Mounted Sirius Heat Heat Pump System - R454B
$2,538 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.1 | 3,000 | 1.1 | 3,000 | 1.04 | 4,800 |
| 5F | 1.88 | 11,300 | 1.99 | 2,100 | 1.88 | 11,300 |
| 17F | 2.71 | 9,800 | 2.66 | 2,900 | 2.14 | 12,400 |
| 47F | 3.86 | 12,000 | 4.96 | 4,400 | 3.5 | 16,100 |
| 95F | 3.66 | 12,000 | 5.71 | 3,700 | 3.57 | 14,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,538 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAW09F2A & DRA1U09S2A 9,000 BTU 24.6 SEER2 Wall Mounted Heat Pump System - R454B
$1,119 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.76 | 4,200 | 1.76 | 4,200 | 1.53 | 5,000 |
| 5F | 2.33 | 8,200 | 2.11 | 3,600 | 2.33 | 8,200 |
| 17F | 2.8 | 8,600 | 2.47 | 3,800 | 2.47 | 10,200 |
| 47F | 3.66 | 10,000 | 5.35 | 4,200 | 3.36 | 14,200 |
| 95F | 4.32 | 9,000 | 4.33 | 3,100 | 3.9 | 10,900 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,119 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAS12F2A & DRA1U12S2A 12,000 BTU 24.6 SEER2 Floor Mounted Heat Pump System - R454B
$1,956 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 0.81 | 800 | 0.81 | 800 | 1.42 | 4,600 |
| 5F | 2.51 | 8,900 | 1.78 | 1,700 | 2.51 | 8,900 |
| 17F | 2.87 | 9,000 | 3.35 | 3,200 | 2.49 | 9,600 |
| 47F | 3.91 | 12,000 | 5.54 | 5,100 | 3.15 | 12,900 |
| 95F | 3.74 | 12,000 | 5.86 | 4,000 | 3.37 | 13,100 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,956 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAW18F2A & DRA1U18S2A 18,000 BTU 24.0 SEER2 Wall Mounted Heat Pump System - R454B
$1,636 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.32 | 2,300 | 1.32 | 2,300 | 1.7 | 8,200 |
| 5F | 2.35 | 13,000 | 2.03 | 3,600 | 2.35 | 13,000 |
| 17F | 2.59 | 13,000 | 2.5 | 4,700 | 2.43 | 15,000 |
| 47F | 3.82 | 18,000 | 5.43 | 7,600 | 3.68 | 22,000 |
| 95F | 3.97 | 18,000 | 3.01 | 3,600 | 3.45 | 20,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,636 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAW12F2A & DRA1H12S2A 12,000 BTU 24.0 SEER2 Wall Mounted Sirius Heat Heat Pump System - R454B
$1,813 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.07 | 2,000 | 1.07 | 2,000 | 1.25 | 5,900 |
| 5F | 1.8 | 11,500 | 1.8 | 4,000 | 1.8 | 11,500 |
| 17F | 2.59 | 10,000 | 2.34 | 5,200 | 1.75 | 12,800 |
| 47F | 3.63 | 12,000 | 4.84 | 3,800 | 3.35 | 16,000 |
| 95F | 3.86 | 12,000 | 8.79 | 3,600 | 3.35 | 13,500 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,813 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAL0612F2A & DRA1H09S2A 9,000 BTU 24.0 SEER2 One-Way Ceiling Cassette Sirius Heat Heat Pump System (w/ Grille) - R454B
$2,349 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 0.56 | 900 | 0.56 | 900 | 1.1 | 5,100 |
| 5F | 1.83 | 10,600 | 1.85 | 4,100 | 1.83 | 10,600 |
| 17F | 2.44 | 9,000 | 2.17 | 5,100 | 2.0 | 11,900 |
| 47F | 3.71 | 10,900 | 3.71 | 3,800 | 3.02 | 13,900 |
| 95F | 4.25 | 9,000 | 7.82 | 4,000 | 3.29 | 12,900 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,349 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAS16F2A & DRA1U18S2A 16,000 BTU 23.8 SEER2 Floor Mounted Heat Pump System - R454B
$2,317 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 0.71 | 1,000 | 0.71 | 1,000 | 1.56 | 8,000 |
| 5F | 2.16 | 13,100 | 1.56 | 2,600 | 2.16 | 13,100 |
| 17F | 2.75 | 14,100 | 2.48 | 4,400 | 2.58 | 14,600 |
| 47F | 3.37 | 17,000 | 5.49 | 7,300 | 3.67 | 22,900 |
| 95F | 3.66 | 16,000 | 3.13 | 4,700 | 3.3 | 18,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,317 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAW24F2A & DRA1U24S2A 24,000 BTU 23.5 SEER2 Wall Mounted Heat Pump System - R454B
$1,939 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.02 | 2,200 | 1.02 | 2,200 | 1.54 | 11,000 |
| 5F | 2.15 | 17,800 | 1.72 | 5,100 | 2.15 | 17,800 |
| 17F | 2.5 | 19,500 | 2.45 | 7,200 | 2.42 | 21,300 |
| 47F | 3.08 | 25,000 | 5.09 | 11,300 | 2.89 | 32,700 |
| 95F | 3.8 | 24,000 | 3.31 | 9,700 | 3.1 | 27,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,939 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAW12F2A & DRA1U12S2A 12,000 BTU 23.1 SEER2 Wall Mounted Heat Pump System - R454B
$1,231 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 0.84 | 800 | 0.84 | 800 | 1.6 | 5,300 |
| 5F | 2.36 | 8,600 | 1.86 | 1,900 | 2.36 | 8,600 |
| 17F | 2.84 | 9,600 | 2.63 | 3,500 | 2.57 | 9,900 |
| 47F | 3.7 | 12,000 | 5.22 | 4,100 | 3.27 | 14,400 |
| 95F | 3.59 | 12,000 | 4.48 | 2,600 | 3.32 | 13,700 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,231 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAL0612F2A & DRA1H12S2A 12,000 BTU 23.0 SEER2 One-Way Ceiling Cassette Sirius Heat Heat Pump System (w/ Grille) - R454B
$2,521 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.1 | 3,000 | 1.1 | 3,000 | 1.09 | 5,100 |
| 5F | 1.99 | 11,500 | 1.99 | 2,100 | 1.99 | 11,500 |
| 17F | 2.65 | 9,600 | 2.66 | 2,900 | 1.95 | 11,900 |
| 47F | 3.56 | 12,500 | 3.74 | 4,600 | 3.23 | 15,200 |
| 95F | 3.82 | 12,000 | 7.82 | 4,000 | 3.31 | 13,900 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,521 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAC0912F2A & DRA1H09S2A 9,000 BTU 22.6 SEER2 Four-Way Ceiling Cassette Sirius Heat Heat Pump System (w/ Grille) - R454B
$2,523 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 0.56 | 900 | 0.56 | 900 | 1.02 | 4,200 |
| 5F | 1.84 | 11,000 | 1.92 | 2,100 | 1.84 | 11,000 |
| 17F | 2.63 | 9,700 | 2.75 | 3,000 | 2.1 | 12,600 |
| 47F | 4.01 | 10,000 | 5.34 | 5,100 | 3.46 | 15,700 |
| 95F | 4.12 | 9,000 | 5.42 | 3,700 | 3.47 | 13,600 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,523 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAF18F2A & DRA1U18S2A 18,000 BTU 22.3 SEER2 Floor Mounted Heat Pump System - R454B
$2,346 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 0.79 | 1,100 | 0.79 | 1,100 | 1.69 | 8,400 |
| 5F | 2.05 | 12,800 | 1.68 | 3,100 | 2.05 | 12,800 |
| 17F | 2.51 | 13,700 | 2.11 | 4,400 | 2.38 | 15,100 |
| 47F | 3.3 | 18,000 | 5.15 | 7,200 | 3.27 | 22,200 |
| 95F | 3.66 | 18,000 | 3.6 | 7,000 | 3.37 | 19,300 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,346 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAW24F2A & DRA1H24S2A 24,000 BTU 22.3 SEER2 Wall Mounted Sirius Heat Heat Pump System - R454B
$2,814 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 0.93 | 2,200 | 0.93 | 2,200 | 1.39 | 10,900 |
| 5F | 2.0 | 24,000 | 1.9 | 12,200 | 2.0 | 24,000 |
| 17F | 2.61 | 21,600 | 2.04 | 14,500 | 2.33 | 23,400 |
| 47F | 3.05 | 26,000 | 5.09 | 11,800 | 3.2 | 28,100 |
| 95F | 3.66 | 23,000 | 3.3 | 16,800 | 3.25 | 24,500 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,814 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAL18F2A & DRA1U18S2A 18,000 BTU 22.2 SEER2 One-Way Ceiling Cassette Heat Pump System (w/ Grille) - R454B
$2,565 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 0.79 | 1,100 | 0.79 | 1,100 | 1.58 | 8,100 |
| 5F | 2.25 | 13,100 | 1.98 | 5,000 | 2.25 | 13,100 |
| 17F | 2.77 | 14,000 | 2.26 | 6,100 | 2.47 | 15,200 |
| 47F | 3.3 | 18,000 | 5.57 | 7,600 | 3.55 | 22,800 |
| 95F | 3.66 | 18,000 | 2.61 | 4,000 | 3.32 | 18,800 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,565 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAC0912F2A & DRA1H12S2A 12,000 BTU 22.2 SEER2 Four-Way Ceiling Cassette Sirius Heat Heat Pump System (w/ Grille) - R454B
$2,696 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 0.56 | 900 | 0.56 | 900 | 1.04 | 4,300 |
| 5F | 1.99 | 11,500 | 2.08 | 2,200 | 1.99 | 11,500 |
| 17F | 2.74 | 10,000 | 2.58 | 3,700 | 2.14 | 12,900 |
| 47F | 3.7 | 12,000 | 5.55 | 5,300 | 3.59 | 16,300 |
| 95F | 3.66 | 12,000 | 5.3 | 3,800 | 3.51 | 15,100 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,696 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAL0612F2A & DRA1U09S2A 9,000 BTU 22.1 SEER2 One-Way Ceiling Cassette Heat Pump System (w/ Grille) - R454B
$1,874 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 0.94 | 900 | 0.94 | 900 | 1.59 | 5,000 |
| 5F | 2.17 | 8,000 | 2.06 | 1,900 | 2.17 | 8,000 |
| 17F | 2.69 | 7,900 | 2.93 | 2,800 | 2.59 | 9,900 |
| 47F | 3.19 | 11,000 | 4.34 | 4,000 | 3.2 | 14,300 |
| 95F | 4.25 | 9,000 | 4.93 | 3,700 | 3.37 | 11,400 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,874 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAL0612F2A & DRA1U12S2A 12,000 BTU 20.0 SEER2 One-Way Ceiling Cassette Heat Pump System (w/ Grille) - R454B
$1,940 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.15 | 1,100 | 1.15 | 1,100 | 1.65 | 5,000 |
| 5F | 2.47 | 8,600 | 2.06 | 1,900 | 2.47 | 8,600 |
| 17F | 2.77 | 8,600 | 3.24 | 3,100 | 2.59 | 10,000 |
| 47F | 3.41 | 12,000 | 4.92 | 4,700 | 3.42 | 15,300 |
| 95F | 3.59 | 12,000 | 5.2 | 3,900 | 3.43 | 13,800 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,940 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAL0612F2A & DRA1H06S2A 6,000 BTU 22.0 SEER2 One-Way Ceiling Cassette Sirius Heat Heat Pump System (w/ Grille) - R454B
$1,890 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 0.91 | 900 | 0.91 | 900 | 1.37 | 4,100 |
| 5F | 2.4 | 8,100 | 2.06 | 1,900 | 2.4 | 8,100 |
| 17F | 2.66 | 7,000 | 2.49 | 2,800 | 2.53 | 9,500 |
| 47F | 3.74 | 7,400 | 3.74 | 3,700 | 3.55 | 11,500 |
| 95F | 4.43 | 6,500 | 7.03 | 3,600 | 3.88 | 12,700 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,890 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAC24F2A & DRA1U24S2A 24,000 BTU 22.0 SEER2 Four-Way Ceiling Cassette Heat Pump System (w/ Grille) - R454B
$3,020 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.49 | 3,300 | 1.49 | 3,300 | 1.6 | 10,400 |
| 5F | 2.3 | 18,500 | 2.33 | 7,000 | 2.3 | 18,500 |
| 17F | 2.73 | 20,400 | 2.93 | 9,400 | 2.55 | 20,500 |
| 47F | 3.2 | 25,000 | 5.31 | 11,600 | 3.43 | 33,100 |
| 95F | 3.52 | 24,000 | 3.96 | 12,300 | 3.06 | 26,800 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $3,020 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAW18F2A & DRA1H18S2A 18,000 BTU 21.7 SEER2 Wall Mounted Sirius Heat Heat Pump System - R454B
$2,197 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.72 | 4,000 | 1.72 | 4,000 | 1.43 | 9,600 |
| 5F | 2.0 | 18,000 | 2.66 | 5,000 | 2.0 | 18,000 |
| 17F | 2.79 | 14,400 | 3.36 | 7,000 | 2.49 | 19,800 |
| 47F | 3.54 | 18,000 | 4.64 | 10,300 | 3.74 | 23,000 |
| 95F | 3.82 | 18,000 | 6.84 | 8,400 | 3.18 | 20,200 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,197 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAC0912F2A & DRA1U09S2A 9,000 BTU 21.6 SEER2 Four-Way Ceiling Cassette Heat Pump System (w/ Grille) - R454B
$2,049 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 0.98 | 1,000 | 0.98 | 1,000 | 1.53 | 4,900 |
| 5F | 2.17 | 8,300 | 1.76 | 2,400 | 2.17 | 8,300 |
| 17F | 2.8 | 8,500 | 3.33 | 3,300 | 2.55 | 9,300 |
| 47F | 4.01 | 10,000 | 5.1 | 4,700 | 3.62 | 13,700 |
| 95F | 4.19 | 9,000 | 4.93 | 3,700 | 3.48 | 12,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,049 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRADL0612F2A & DRA1H06S2A 6,000 BTU 21.4 SEER2 Low Static Ducted Sirius Heat Heat Pump System - R454B
$1,709 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.28 | 1,700 | 1.28 | 1,700 | 1.47 | 4,000 |
| 5F | 2.41 | 7,800 | 1.58 | 2,370 | 2.41 | 7,800 |
| 17F | 2.69 | 8,000 | 2.06 | 3,300 | 2.52 | 9,100 |
| 47F | 4.04 | 8,000 | 4.52 | 3,700 | 3.1 | 11,100 |
| 95F | 4.23 | 6,500 | 5.17 | 3,000 | 3.53 | 11,800 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,709 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRADL0612F2A & DRA1H09S2A 9,000 BTU 21.4 SEER2 Low Static Ducted Sirius Heat Heat Pump System - R454B
$2,168 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.35 | 1,800 | 1.35 | 1,800 | 1.28 | 6,400 |
| 5F | 1.89 | 11,200 | 1.6 | 2,400 | 1.89 | 11,200 |
| 17F | 2.49 | 9,600 | 2.06 | 3,300 | 1.99 | 12,600 |
| 47F | 3.53 | 10,000 | 4.28 | 3,800 | 3.23 | 16,000 |
| 95F | 3.94 | 9,000 | 5.05 | 3,100 | 3.3 | 13,500 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,168 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAC0912F2A & DRA1U12S2A 12,000 BTU 21.1 SEER2 Four-Way Ceiling Cassette Heat Pump System (w/ Grille) - R454B
$2,114 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 0.98 | 1,000 | 0.98 | 1,000 | 1.67 | 5,300 |
| 5F | 2.39 | 8,400 | 1.76 | 2,400 | 2.39 | 8,400 |
| 17F | 2.8 | 8,500 | 3.33 | 3,300 | 2.55 | 9,300 |
| 47F | 3.55 | 12,000 | 5.1 | 4,700 | 3.66 | 15,000 |
| 95F | 3.66 | 12,000 | 4.93 | 3,700 | 3.56 | 14,100 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,114 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAF24F2A & DRA1U24S2A 24,000 BTU 21.1 SEER2 Floor Mounted Heat Pump System - R454B
$2,697 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.38 | 3,200 | 1.38 | 3,200 | 1.29 | 7,900 |
| 5F | 2.27 | 18,600 | 2.01 | 5,700 | 2.27 | 18,600 |
| 17F | 2.56 | 20,000 | 2.5 | 7,600 | 2.31 | 20,000 |
| 47F | 2.99 | 24,400 | 5.09 | 11,800 | 3.2 | 32,600 |
| 95F | 3.57 | 24,000 | 3.97 | 11,100 | 3.26 | 29,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,697 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAC18F2A & DRA1U18S2A 18,000 BTU 20.7 SEER2 Four-Way Ceiling Cassette Heat Pump System (w/ Grille) - R454B
$2,583 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 0.79 | 1,100 | 0.79 | 1,100 | 1.63 | 8,300 |
| 5F | 2.19 | 12,800 | 1.71 | 3,800 | 2.19 | 12,800 |
| 17F | 2.66 | 13,900 | 1.98 | 4,800 | 2.36 | 14,800 |
| 47F | 3.36 | 18,000 | 5.2 | 7,100 | 3.26 | 21,500 |
| 95F | 3.67 | 16,800 | 3.17 | 5,300 | 3.22 | 17,800 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,583 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAC24F2A & DRA1H24S2A 24,000 BTU 22.2 SEER2 Four-Way Ceiling Cassette Sirius Heat Heat Pump System (w/ Grille) - R454B
$3,870 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.22 | 3,800 | 1.22 | 3,800 | 1.16 | 9,500 |
| 5F | 2.23 | 23,800 | 2.07 | 7,200 | 2.23 | 23,800 |
| 17F | 2.78 | 20,400 | 2.47 | 9,100 | 2.48 | 23,900 |
| 47F | 3.54 | 25,000 | 4.88 | 11,500 | 3.61 | 30,700 |
| 95F | 3.52 | 23,400 | 3.91 | 12,800 | 3.34 | 26,200 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $3,870 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAL18F2A & DRA1H18S2A 18,000 BTU 20.6 SEER2 One-Way Ceiling Cassette Sirius Heat Heat Pump System (w/ Grille) - R454B
$3,126 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 0.76 | 4,000 | 0.76 | 4,000 | 1.47 | 9,500 |
| 5F | 1.89 | 17,500 | 1.79 | 3,300 | 1.89 | 17,500 |
| 17F | 2.5 | 14,500 | 1.99 | 3,800 | 2.05 | 18,800 |
| 47F | 3.01 | 20,000 | 3.07 | 8,900 | 3.27 | 22,200 |
| 95F | 3.65 | 16,700 | 3.04 | 5,700 | 3.28 | 19,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $3,126 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRADH0912F2A & DRA1H09S2A 9,000 BTU 20.5 SEER2 High Static Ducted Sirius Heat Heat Pump System - R454B
$2,372 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.4 | 2,000 | 1.4 | 2,000 | 1.18 | 5,900 |
| 5F | 1.85 | 11,900 | 1.47 | 2,500 | 1.85 | 11,900 |
| 17F | 2.45 | 10,200 | 1.62 | 3,200 | 1.94 | 12,600 |
| 47F | 3.87 | 9,900 | 4.4 | 3,900 | 3.41 | 16,500 |
| 95F | 4.12 | 9,000 | 5.86 | 3,000 | 3.05 | 13,100 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,372 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAF18F2A & DRA1H18S2A 18,000 BTU 20.4 SEER2 Floor Mounted Sirius Heat Heat Pump System - R454B
$2,907 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 0.79 | 1,100 | 0.79 | 1,100 | 1.33 | 8,400 |
| 5F | 1.86 | 17,000 | 1.6 | 4,800 | 1.86 | 17,000 |
| 17F | 2.54 | 14,400 | 2.3 | 7,600 | 2.24 | 20,200 |
| 47F | 3.08 | 19,000 | 4.59 | 8,300 | 3.32 | 20,700 |
| 95F | 3.66 | 17,000 | 4.34 | 7,400 | 3.37 | 19,200 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,907 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAF24F2A & DRA1H24S2A 24,000 BTU 20.4 SEER2 Floor Mounted Sirius Heat Heat Pump System - R454B
$3,547 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.4 | 4,200 | 1.4 | 4,200 | 1.33 | 10,500 |
| 5F | 2.16 | 24,200 | 1.61 | 4,900 | 2.16 | 24,200 |
| 17F | 2.74 | 20,200 | 2.52 | 7,900 | 2.38 | 23,300 |
| 47F | 3.34 | 26,000 | 5.26 | 11,300 | 3.36 | 29,500 |
| 95F | 3.52 | 22,000 | 3.8 | 12,700 | 3.26 | 25,600 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $3,547 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRADL0612F2A & DRA1H12S2A 12,000 BTU 20.0 SEER2 Low Static Ducted Sirius Heat Heat Pump System - R454B
$2,340 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.35 | 1,800 | 1.35 | 1,800 | 1.28 | 6,400 |
| 5F | 1.9 | 11,800 | 1.6 | 2,400 | 1.9 | 11,800 |
| 17F | 2.49 | 9,600 | 2.06 | 3,300 | 1.99 | 13,100 |
| 47F | 3.39 | 12,500 | 4.28 | 3,800 | 3.27 | 16,200 |
| 95F | 3.52 | 12,000 | 5.05 | 3,100 | 3.3 | 13,500 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,340 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRADH18F2A & DRA1U18S2A 18,000 BTU 20.0 SEER2 High Static Ducted Heat Pump System - R454B
$2,487 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.44 | 2,700 | 1.44 | 2,700 | 1.65 | 8,500 |
| 5F | 2.41 | 14,200 | 1.69 | 3,400 | 2.41 | 14,200 |
| 17F | 2.89 | 14,900 | 2.02 | 4,200 | 2.65 | 15,900 |
| 47F | 3.91 | 20,000 | 4.92 | 5,200 | 3.92 | 23,000 |
| 95F | 3.89 | 17,500 | 3.3 | 4,500 | 3.34 | 20,200 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,487 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRADL18F2A & DRA1U18S2A 18,000 BTU 20.0 SEER2 Low Static Ducted Heat Pump System - R454B
$2,515 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 0.62 | 1,900 | 0.62 | 1,900 | 1.49 | 7,000 |
| 5F | 2.19 | 14,000 | 1.78 | 3,400 | 2.19 | 14,000 |
| 17F | 2.6 | 14,000 | 2.26 | 4,400 | 2.4 | 14,100 |
| 47F | 3.47 | 20,000 | 4.88 | 5,500 | 3.49 | 22,000 |
| 95F | 3.66 | 17,000 | 4.1 | 3,500 | 3.18 | 19,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,515 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRADH0912F2A & DRA1H12S2A 12,000 BTU 20.5 SEER2 High Static Ducted Sirius Heat Heat Pump System - R454B
$2,544 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.4 | 2,000 | 1.4 | 2,000 | 1.37 | 6,900 |
| 5F | 1.95 | 12,000 | 1.47 | 2,500 | 1.95 | 12,000 |
| 17F | 2.6 | 10,200 | 1.62 | 3,200 | 2.31 | 14,000 |
| 47F | 3.63 | 12,000 | 4.4 | 3,900 | 3.41 | 16,500 |
| 95F | 3.52 | 12,000 | 5.86 | 3,000 | 3.09 | 13,300 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,544 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAS16F2A & DRA1H18S2A 16,000 BTU 20.0 SEER2 Floor Mounted Sirius Heat Heat Pump System - R454B
$2,878 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 0.76 | 4,000 | 0.76 | 4,000 | 1.21 | 7,600 |
| 5F | 1.95 | 17,500 | 1.67 | 5,000 | 1.95 | 17,500 |
| 17F | 2.6 | 14,200 | 2.06 | 6,600 | 2.13 | 18,800 |
| 47F | 2.85 | 17,000 | 4.2 | 6,600 | 3.12 | 20,000 |
| 95F | 3.66 | 16,000 | 3.07 | 6,500 | 3.15 | 17,200 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,878 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAW33F2A & DRA1H33S2A 33,000 BTU 20.0 SEER2 Wall Mounted Sirius Heat Heat Pump System - R454B
$3,023 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 0.91 | 3,600 | 0.91 | 3,600 | 1.35 | 17,800 |
| 5F | 1.91 | 34,600 | 1.63 | 3,900 | 1.91 | 34,600 |
| 17F | 2.61 | 29,600 | 3.47 | 15,400 | 2.0 | 30,200 |
| 47F | 3.22 | 36,000 | 4.67 | 19,900 | 2.72 | 38,200 |
| 95F | 3.43 | 33,000 | 9.99 | 15,000 | 3.05 | 35,900 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $3,023 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAC18F2A & DRA1H18S2A 18,000 BTU 20.0 SEER2 Four-Way Ceiling Cassette Sirius Heat Heat Pump System (w/ Grille) - R454B
$3,144 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 0.76 | 4,000 | 0.76 | 4,000 | 1.25 | 8,100 |
| 5F | 1.9 | 17,000 | 1.15 | 3,800 | 1.9 | 17,000 |
| 17F | 2.7 | 14,900 | 2.24 | 7,100 | 2.1 | 18,000 |
| 47F | 3.18 | 19,000 | 5.1 | 8,700 | 3.01 | 20,000 |
| 95F | 3.66 | 16,000 | 2.97 | 7,100 | 3.31 | 18,500 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $3,144 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRADH0912F2A & DRA1U09S2A 9,000 BTU 19.7 SEER2 High Static Ducted Heat Pump System - R454B
$1,897 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.12 | 1,300 | 1.12 | 1,300 | 1.2 | 3,800 |
| 5F | 2.32 | 8,300 | 1.34 | 2,100 | 2.32 | 8,300 |
| 17F | 2.9 | 9,300 | 1.61 | 2,800 | 2.56 | 9,800 |
| 47F | 3.96 | 10,000 | 4.22 | 3,600 | 3.7 | 14,500 |
| 95F | 3.82 | 9,000 | 2.93 | 2,000 | 3.28 | 11,200 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,897 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAM24F2A & DRA1U24S2A 24,000 BTU 19.7 SEER2 Multi-Position Air Handler Heat Pump System - R454B
$3,939 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 0.82 | 3,300 | 0.82 | 3,300 | 1.88 | 14,400 |
| 5F | 2.2 | 18,000 | 1.74 | 5,400 | 2.2 | 18,000 |
| 17F | 2.4 | 17,600 | 1.98 | 5,000 | 2.55 | 23,200 |
| 47F | 3.54 | 25,000 | 4.15 | 5,800 | 3.36 | 33,800 |
| 95F | 3.43 | 24,000 | 3.33 | 6,700 | 3.05 | 29,600 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $3,939 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRADL0612F2A & DRA1U09S2A 9,000 BTU 19.5 SEER2 Low Static Ducted Heat Pump System - R454B
$1,693 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.12 | 1,300 | 1.12 | 1,300 | 1.74 | 5,700 |
| 5F | 2.25 | 8,600 | 1.6 | 2,400 | 2.25 | 8,600 |
| 17F | 2.61 | 8,900 | 1.89 | 3,100 | 2.45 | 9,600 |
| 47F | 3.66 | 10,000 | 4.22 | 3,600 | 3.45 | 14,000 |
| 95F | 3.77 | 9,000 | 5.17 | 3,000 | 3.35 | 11,900 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,693 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRADH0912F2A & DRA1U12S2A 12,000 BTU 19.5 SEER2 High Static Ducted Heat Pump System - R454B
$1,962 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.12 | 1,300 | 1.12 | 1,300 | 1.6 | 5,200 |
| 5F | 2.44 | 8,900 | 1.4 | 2,000 | 2.44 | 8,900 |
| 17F | 2.78 | 9,100 | 1.71 | 2,800 | 2.52 | 9,800 |
| 47F | 3.78 | 12,000 | 4.17 | 3,700 | 3.33 | 15,700 |
| 95F | 3.52 | 12,000 | 2.93 | 2,200 | 2.98 | 12,200 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,962 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRADL0612F2A & DRA1U12S2A 12,000 BTU 19.0 SEER2 Low Static Ducted Heat Pump System - R454B
$1,759 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.12 | 1,300 | 1.12 | 1,300 | 1.74 | 5,700 |
| 5F | 2.24 | 8,800 | 1.6 | 2,400 | 2.24 | 8,800 |
| 17F | 2.58 | 9,500 | 1.89 | 3,100 | 2.58 | 10,300 |
| 47F | 3.41 | 12,000 | 4.17 | 3,700 | 3.49 | 15,600 |
| 95F | 3.44 | 11,500 | 5.17 | 3,000 | 3.15 | 13,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $1,759 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRADH24F2A & DRA1U24S2A 24,000 BTU 19.0 SEER2 High Static Ducted Heat Pump System - R454B
$2,954 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.27 | 2,900 | 1.27 | 2,900 | 1.71 | 12,400 |
| 5F | 2.3 | 19,000 | 1.88 | 4,500 | 2.3 | 19,000 |
| 17F | 2.6 | 21,200 | 2.15 | 5,500 | 2.56 | 21,600 |
| 47F | 3.65 | 25,000 | 4.54 | 6,500 | 3.43 | 35,100 |
| 95F | 3.66 | 24,000 | 3.28 | 5,600 | 3.06 | 28,300 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,954 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRADH24F2A & DRA1H24S2A 24,000 BTU 19.0 SEER2 High Static Ducted Sirius Heat Heat Pump System - R454B
$2,954 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.29 | 4,000 | 1.29 | 4,000 | 1.28 | 10,200 |
| 5F | 2.18 | 24,000 | 1.19 | 4,300 | 2.18 | 24,000 |
| 17F | 2.71 | 21,600 | 1.91 | 6,700 | 2.48 | 23,600 |
| 47F | 3.81 | 26,000 | 4.86 | 7,300 | 3.71 | 31,400 |
| 95F | 3.52 | 24,000 | 3.26 | 5,000 | 3.4 | 28,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,954 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRUM1824S2A & DRU1H18S2A 18,000 BTU 19 SEER2 Multi-Position Air Handler Sirius Heat Heat Pump System - R454B
$4,197 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.55 | 4,500 | 1.55 | 4,500 | 1.77 | 13,000 |
| 5F | 2.0 | 18,000 | 1.81 | 5,200 | 2.0 | 18,000 |
| 17F | 2.6 | 15,000 | 2.26 | 5,700 | 2.3 | 21,600 |
| 47F | 3.2 | 19,000 | 3.52 | 6,000 | 3.31 | 22,000 |
| 95F | 3.66 | 18,000 | 3.73 | 5,600 | 3.31 | 22,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $4,197 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAM24F2A & DRA1H24S2A 24,000 BTU 18.7 SEER2 Multi-Position Air Handler Sirius Heat Heat Pump System - R454B
$4,883 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 0.77 | 3,400 | 0.77 | 3,400 | 1.28 | 10,500 |
| 5F | 2.1 | 23,600 | 1.91 | 6,200 | 2.1 | 23,600 |
| 17F | 2.4 | 16,900 | 2.19 | 5,600 | 2.39 | 24,000 |
| 47F | 3.5 | 26,000 | 6.29 | 8,800 | 3.27 | 29,000 |
| 95F | 3.51 | 23,000 | 7.85 | 7,500 | 3.04 | 27,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $4,883 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAM18F2A & DRA1U18S2A 18,000 BTU 18.5 SEER2 Air Handler Heat Pump System - R454B
$2,921 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.12 | 2,300 | 1.12 | 2,300 | 1.6 | 8,300 |
| 5F | 2.3 | 13,000 | 1.94 | 3,700 | 2.3 | 13,000 |
| 17F | 2.6 | 13,200 | 2.32 | 4,200 | 2.48 | 14,800 |
| 47F | 3.59 | 18,000 | 4.88 | 5,500 | 3.55 | 21,800 |
| 95F | 3.54 | 18,000 | 3.49 | 5,600 | 3.23 | 20,400 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $2,921 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRADH18F2A & DRA1H18S2A 18,000 BTU 18.4 SEER2 High Static Ducted Sirius Heat Heat Pump System - R454B
$3,048 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.19 | 2,400 | 1.19 | 2,400 | 1.51 | 9,000 |
| 5F | 2.1 | 18,000 | 1.55 | 3,700 | 2.1 | 18,000 |
| 17F | 2.89 | 15,000 | 1.45 | 4,200 | 2.5 | 20,000 |
| 47F | 3.59 | 19,500 | 4.65 | 5,400 | 3.85 | 23,000 |
| 95F | 3.51 | 17,500 | 3.35 | 4,000 | 3.37 | 20,600 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $3,048 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRUM1824S2A & DRU1H24S2A 24,000 BTU 18.3 SEER2 Multi-Position Air Handler Sirius Heat Heat Pump System - R454B
$4,696 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.01 | 3,300 | 1.01 | 3,300 | 1.6 | 14,400 |
| 5F | 1.87 | 21,600 | 2.21 | 14,400 | 1.87 | 21,600 |
| 17F | 2.42 | 20,000 | 2.74 | 8,500 | 2.24 | 22,200 |
| 47F | 3.17 | 26,000 | 4.86 | 7,300 | 3.28 | 30,600 |
| 95F | 3.23 | 24,000 | 3.98 | 7,200 | 2.86 | 28,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $4,696 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRADL18F2A & DRA1H18S2A 18,000 BTU 18.0 SEER2 Low Static Ducted Sirius Heat Heat Pump System - R454B
$3,076 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.22 | 2,200 | 1.22 | 2,200 | 1.51 | 9,000 |
| 5F | 2.0 | 18,000 | 1.52 | 3,900 | 2.0 | 18,000 |
| 17F | 2.7 | 15,000 | 1.42 | 4,300 | 2.23 | 19,000 |
| 47F | 3.37 | 19,000 | 4.32 | 5,900 | 2.87 | 22,000 |
| 95F | 3.51 | 17,000 | 4.1 | 3,500 | 3.15 | 18,800 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $3,076 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRAM18F2A & DRA1H18S2A 18,000 BTU 18.0 SEER2 Multi-Position Air Handler Sirius Heat Heat Pump System - R454B
$3,482 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.01 | 2,550 | 1.01 | 2,550 | 1.47 | 9,100 |
| 5F | 2.2 | 18,000 | 2.2 | 5,850 | 2.2 | 18,000 |
| 17F | 2.6 | 14,000 | 2.32 | 5,550 | 2.38 | 19,800 |
| 47F | 3.64 | 19,500 | 4.88 | 5,000 | 3.3 | 21,600 |
| 95F | 3.52 | 18,000 | 7.03 | 6,000 | 3.15 | 20,400 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $3,482 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRUM3036S2A & DRU1H36S2A 36,000 BTU 17.4 SEER2 Multi-Position Air Handler Sirius Heat Heat Pump System - R454B
$6,746 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.28 | 6,600 | 1.28 | 6,600 | 1.59 | 27,800 |
| 5F | 1.9 | 39,000 | 1.69 | 7,400 | 1.9 | 39,000 |
| 17F | 2.56 | 31,800 | 2.2 | 10,500 | 2.03 | 41,000 |
| 47F | 3.6 | 37,000 | 4.81 | 11,000 | 3.22 | 48,000 |
| 95F | 3.43 | 36,000 | 3.51 | 9,700 | 2.77 | 42,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $6,746 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRUM3036SWA & DRU1U30S2A 30,000 BTU 17 SEER2 Multi-Position Air Handler Side Discharge Heat Pump System - R454B
$5,206 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 0.82 | 2,400 | 0.82 | 2,400 | 1.25 | 12,000 |
| 5F | 2.0 | 19,100 | 1.49 | 5,700 | 2.0 | 19,100 |
| 17F | 2.4 | 18,500 | 1.7 | 6,100 | 2.26 | 20,200 |
| 47F | 3.49 | 31,000 | 4.08 | 6,400 | 3.63 | 32,200 |
| 95F | 3.14 | 30,000 | 4.18 | 10,400 | 3.08 | 34,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $5,206 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRUM3036S2A & DRU1H30S2A 30,000 BTU 16.8 SEER2 Multi-Position Air Handler Sirius Heat Heat Pump System - R454B
$5,862 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 1.47 | 7,300 | 1.47 | 7,300 | 1.55 | 20,100 |
| 5F | 1.96 | 32,600 | 2.13 | 9,600 | 1.96 | 32,600 |
| 17F | 2.76 | 23,800 | 2.59 | 9,900 | 2.39 | 37,800 |
| 47F | 3.66 | 34,000 | 4.57 | 10,300 | 3.74 | 38,500 |
| 95F | 3.43 | 30,000 | 4.41 | 12,800 | 3.16 | 39,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $5,862 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRUM4260S2A & DRU1H42S2A 42,000 BTU 16.7 SEER2 Multi-Position Air Handler Sirius Heat Heat Pump System - R454B
$7,857 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 3.16 | 15,300 | 3.16 | 15,300 | 1.32 | 25,900 |
| 5F | 1.9 | 46,000 | 2.44 | 13,500 | 1.9 | 46,000 |
| 17F | 2.7 | 37,000 | 2.86 | 16,700 | 2.02 | 38,300 |
| 47F | 3.4 | 50,000 | 4.37 | 15,500 | 3.23 | 57,300 |
| 95F | 3.43 | 42,000 | 3.41 | 15,600 | 2.89 | 51,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $7,857 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRUM4260S2A & DRU1H48S2A 48,000 BTU 16.5 SEER2 Multi-Position Air Handler Sirius Heat Heat Pump System - R454B
$8,215 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 3.16 | 15,300 | 3.16 | 15,300 | 1.32 | 25,900 |
| 5F | 1.9 | 46,000 | 2.44 | 13,500 | 1.9 | 46,000 |
| 17F | 2.7 | 37,000 | 2.86 | 16,700 | 2.02 | 38,300 |
| 47F | 3.4 | 50,000 | 4.37 | 15,500 | 3.23 | 57,300 |
| 95F | 3.08 | 48,000 | 3.41 | 15,600 | 2.89 | 51,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $8,215 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRUM4260S2A & DRU1H49S2A 49,000 BTU 16.3 SEER2 Multi-Position Air Handler Sirius Heat Heat Pump System - R454B
$8,755 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 0.86 | 6,700 | 0.86 | 6,700 | 1.46 | 30,900 |
| 5F | 1.8 | 52,000 | 1.72 | 14,200 | 1.8 | 52,000 |
| 17F | 2.4 | 45,000 | 2.61 | 16,400 | 2.3 | 50,400 |
| 47F | 3.1 | 56,000 | 3.3 | 8,100 | 3.17 | 64,500 |
| 95F | 3.43 | 48,000 | 2.18 | 11,400 | 2.57 | 56,300 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $8,755 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRUM3036SWA & DRU1U36S2A 36,000 BTU 16.1 SEER2 Multi-Position Air Handler Side Discharge Heat Pump System - R454B
$5,399 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.08 | 5,100 | 1.08 | 5,100 | 1.33 | 14,100 |
| 5F | 2.0 | 27,000 | 1.66 | 6,800 | 2.0 | 27,000 |
| 17F | 2.6 | 25,600 | 2.26 | 7,800 | 2.19 | 26,200 |
| 47F | 3.4 | 36,000 | 4.27 | 6,700 | 3.3 | 40,000 |
| 95F | 2.93 | 36,000 | 3.47 | 8,400 | 2.73 | 39,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $5,399 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRUM4260SWA & DRU1U42S2A 42,000 BTU 16.0 SEER2 Multi-Position Air Handler Side Discharge Heat Pump System - R454B
$6,991 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.09 | 5,400 | 1.09 | 5,400 | 1.63 | 32,500 |
| 5F | 1.85 | 38,000 | 2.15 | 12,300 | 1.85 | 38,000 |
| 17F | 2.46 | 32,400 | 2.6 | 15,500 | 2.0 | 35,400 |
| 47F | 3.46 | 48,000 | 4.4 | 15,300 | 3.12 | 49,500 |
| 95F | 2.93 | 48,000 | 3.47 | 16,600 | 2.73 | 49,900 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $6,991 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRUM4260S2A & DRU1H60S2A 60,000 BTU 16 SEER2 Multi-Position Air Handler Sirius Heat Heat Pump System - R454B
$8,895 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -22.0F | 0.86 | 6,700 | 0.86 | 6,700 | 1.46 | 30,900 |
| 5F | 1.8 | 52,000 | 1.72 | 14,200 | 1.8 | 52,000 |
| 17F | 2.4 | 45,000 | 2.61 | 16,400 | 2.3 | 50,400 |
| 47F | 3.1 | 56,000 | 3.3 | 8,100 | 3.17 | 64,500 |
| 95F | 2.93 | 54,000 | 2.18 | 11,400 | 2.57 | 56,300 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $8,895 |
| Energy Cost | - |
| 10-Year Cost | - |
|
Durastar DRUM4260SWA & DRU1U60S2A 60,000 BTU 15.2 SEER2 Multi-Position Air Handler Side Discharge Heat Pump System - R454B
$7,284 at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | @ rated BTU | COP | @ min BTU | COP | @ max BTU |
| -13.0F | 1.5 | 7,600 | 1.5 | 7,600 | 1.64 | 29,000 |
| 5F | 1.8 | 38,000 | 2.43 | 14,100 | 1.8 | 38,000 |
| 17F | 2.34 | 33,000 | 2.85 | 17,200 | 1.96 | 35,800 |
| 47F | 3.38 | 54,000 | 7.86 | 26,000 | 3.35 | 55,000 |
| 95F | 2.52 | 54,000 | 3.44 | 21,000 | 2.51 | 55,000 |
|
| kWh Per Year, Just Heatpump | - |
| kWh Backup Heat Needed | - |
| kWh Total per Year | - |
| Hours Over Capacity | - |
| Hours Short Cycling | - |
| Purchase Cost | $7,284 |
| Energy Cost | - |
| 10-Year Cost | - |
|