Heat Pumps for the Mountain West

Mountain West climates are cold and dry — Denver gets 150+ days below freezing — but electricity is reasonable at $0.15/kWh. Cold-weather COP matters here. This tool calculates total 10-year cost including supplemental heating for hours when the unit can't keep up. Cold-climate models are pre-filtered. Set your location on the map for results with your local weather data.

537 heat pumps match this filter. Showing top 50 by SEER2.

NameBrandRefrigerantPerformanceOperation
Carrier 45M Series 6k BTU Wall Mount
$3,400 at HVACDirect
CARRIER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.144,100--1.297,500
5F2.013,5001.159002.013,500
17F2.4111,0001.951,6002.2614,600
47F4.09,0005.864,0003.1917,200
95F5.176,0005.053,1003.516,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,400
Energy cost-
Total cost-
Mitsubishi Electric M-Series 6k BTU Wall Mount
$2,492 (2 stores)
MITSUBISHI ELECTRIC R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-10.0F1.98810--1.939,000
5F2.3812,6002.391,1402.3812,600
17F3.456,0002.741,3102.6914,400
47F4.889,0004.151,7003.3120,000
95F6.286,0004.151,7003.3114,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,492
Energy cost-
Total cost-
Fujitsu AirStage H-Series 9k BTU Wall Mount
$3,127 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F2.811,340--1.7713,200
5F2.4817,0003.321,7002.4817,000
17F3.747,4004.192,0002.6119,500
47F5.4112,0006.043,3003.0724,000
95F5.619,0007.573,1004.0515,200
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,127
Energy cost-
Total cost-
Carrier 45M Series 9k BTU Wall Mount
$3,600 at HVACDirect
CARRIER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.144,100--1.297,500
5F2.013,5001.159002.013,500
17F2.4111,0001.951,6002.2614,600
47F3.5912,0005.864,0003.1917,200
95F4.989,0005.053,1003.516,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,600
Energy cost-
Total cost-
Mitsubishi Electric M-Series 9k BTU Wall Mount
$2,811 (2 stores)
MITSUBISHI ELECTRIC R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-10.0F2.051,470--2.0112,000
5F2.214,7002.21,8002.214,700
17F3.477,7002.442,0002.3916,300
47F4.9512,0005.053,1002.9321,300
95F5.389,0004.582,5002.7815,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,811
Energy cost-
Total cost-
Fujitsu AirStage H-Series 9k BTU Wall Mount
$2,786 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-15.0F2.231,370--1.711,400
5F2.2615,4003.091,9002.2615,400
17F3.67,5003.392,2002.4917,500
47F5.3312,0005.133,5003.0823,000
95F5.59,0008.263,1003.9812,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,786
Energy cost-
Total cost-
Fujitsu AirStage H-Series 12k BTU Wall Mount
$3,396 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F3.091,900--1.7615,300
5F2.6216,2003.862,5002.1820,500
17F3.479,6004.722,9002.5922,800
47F4.8715,3006.284,5003.5927,300
95F4.8812,0007.573,1003.8417,300
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,396
Energy cost-
Total cost-
Fujitsu AirStage H-Series 12k BTU Wall Mount
$3,051 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-15.0F2.741,400--1.8112,200
5F2.1616,6003.361,9502.1616,600
17F3.4510,0003.392,2002.4418,700
47F4.6416,0005.133,5003.0723,600
95F4.6912,0008.263,1003.8416,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,051
Energy cost-
Total cost-
Gree Airy 9k BTU Wall Mount
$2,932 at HVACDirect
GREE R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F4.232,600--1.647,400
5F2.1111,5004.232,6002.1111,500
17F3.228,9004.322,8002.0613,000
47F4.4410,6005.282,7003.7516,000
95F4.949,1008.372,0003.1614,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,932
Energy cost-
Total cost-
Fujitsu AirStage H-Series 9k BTU Wall Mount
$2,156 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
5F2.3210,3002.552,0002.3210,300
17F3.247,4002.931,7002.6212,600
47F4.6312,0005.862,8002.6414,500
95F4.89,0006.993,1003.7712,100
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,156
Energy cost-
Total cost-
Mitsubishi Electric M-Series 12k BTU Wall Mount
$3,158 (2 stores)
MITSUBISHI ELECTRIC R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-10.0F2.011,510--2.0113,200
5F2.216,2002.261,8502.216,200
17F3.419,3002.542,0802.4918,200
47F4.213,2005.053,1003.2223,500
95F4.5112,0004.582,5002.8416,100
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,158
Energy cost-
Total cost-
Carrier 45M Series 12k BTU Wall Mount
$3,900 at HVACDirect
CARRIER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.144,100--1.297,500
5F2.013,5001.159002.013,500
17F2.4111,0001.951,6002.2614,600
47F3.5912,0005.864,0003.1917,200
95F4.1912,0005.053,1003.516,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,900
Energy cost-
Total cost-
Gree Airy 12k BTU Wall Mount
$3,114 at HVACDirect
GREE R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F4.232,600--1.758,500
5F2.012,2004.232,6002.012,200
17F3.1110,3004.322,8002.0613,000
47F4.5312,2005.043,2703.7716,200
95F4.4512,00010.622,9003.8317,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,114
Energy cost-
Total cost-
Fujitsu AirStage H-Series 14k BTU Wall Mount
$3,674 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F3.452,000--1.7217,400
5F2.5418,4003.962,7002.023,500
17F3.4410,8004.562,8002.2924,300
47F4.7217,4006.284,5003.5728,000
95F4.5214,5007.143,9003.4919,400
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,674
Energy cost-
Total cost-
Mitsubishi Electric M-Series 9k BTU Wall Mount
$2,465 (2 stores)
MITSUBISHI ELECTRIC R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-10.0F1.96670--1.957,450
5F1.89,6002.298601.89,600
17F2.665,9002.321,0302.3911,500
47F4.859,6005.693,3002.6615,900
95F4.559,0004.473,2003.4112,200
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,465
Energy cost-
Total cost-
Mitsubishi Electric M-Series 9k BTU Wall Mount
$1,940 (2 stores)
MITSUBISHI ELECTRIC R-410A
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-4.0F2.121,230--2.086,180
5F2.127,9002.11,5802.127,900
17F2.616,5002.392,0402.4310,200
47F4.4410,9005.734,5002.6815,900
95F4.559,0004.43,6003.4112,200
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,940
Energy cost-
Total cost-
Mitsubishi Electric M-Series 9k BTU Wall Mount
$2,241 (2 stores)
MITSUBISHI ELECTRIC R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-10.0F1.41480--1.435,330
5F1.88,1001.867001.88,100
17F2.696,7002.229102.1510,200
47F4.4410,9005.693,3002.6815,900
95F4.559,0004.473,2003.4112,200
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,241
Energy cost-
Total cost-
Gree Airy 18k BTU Wall Mount
$4,101 at HVACDirect
GREE R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F2.145,100--1.2310,800
5F1.818,0002.496,8001.818,000
17F2.8615,5002.618,0001.920,100
47F4.0118,6005.235,0003.2423,000
95F4.1918,0006.014,1003.1925,590
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$4,101
Energy cost-
Total cost-
Fujitsu AirStage H-Series 12k BTU Wall Mount
$2,374 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
5F2.3910,6002.552,0002.3910,600
17F3.118,7002.931,7002.6513,200
47F4.3214,0005.862,8002.515,000
95F3.9512,0006.993,1003.2613,800
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,374
Energy cost-
Total cost-
Fujitsu AirStage H-Series 14k BTU Wall Mount
$3,274 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-15.0F0.661,900--1.9216,400
5F2.121,0003.492,5002.121,000
17F3.4411,4003.812,6002.3522,000
47F4.5918,0005.074,1503.2625,000
95F4.3414,5006.063,1003.2819,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,274
Energy cost-
Total cost-
Carrier 45M Series 9k BTU Wall Mount
$2,560 at HVACDirect
CARRIER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.172,000--1.115,100
5F1.811,5001.724,1001.811,500
17F2.719,8002.225,3001.7512,800
47F3.7412,0004.843,8003.3516,000
95F4.559,0008.573,8003.3513,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,560
Energy cost-
Total cost-
ACiQ 9k BTU Wall Mount
$1,495 at HVACDirect
ACIQ R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.172,000--1.115,100
5F1.811,5001.724,1001.811,500
17F2.719,8002.225,3001.7512,800
47F3.7412,0004.843,8003.3516,000
95F4.559,0008.573,8003.3513,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,495
Energy cost-
Total cost-
Senville SENA Series 9k BTU Wall Mount
$1,300 at Amazon
SENVILLE R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.172,000--1.115,100
5F1.811,5001.724,1001.811,500
17F2.719,8002.225,3001.7512,800
47F3.7412,0004.843,8003.3516,000
95F4.559,0008.573,8003.3513,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,300
Energy cost-
Total cost-
Cooper & Hunter CH Series 9k BTU Floor Mount
$1,698 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.042,700--1.024,700
5F1.8411,3001.832,0001.8411,300
17F2.719,8002.492,8002.1712,200
47F4.49,0004.964,4003.516,100
95F4.49,0005.713,7003.4913,700
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,698
Energy cost-
Total cost-
ACiQ 9k BTU Floor Mount
$1,900 at HVACDirect
ACIQ R454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.042,700--1.024,700
5F1.8411,3001.832,0001.8411,300
17F2.719,8002.492,8002.1712,200
47F4.49,0004.964,4003.516,100
95F4.49,0005.713,7003.4913,700
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,900
Energy cost-
Total cost-
Durastar DRA Series 9k BTU Floor Mount
$2,169 at GotDuctless
DURASTAR R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.042,700--1.024,700
5F1.8411,3001.832,0001.8411,300
17F2.719,8002.492,8002.1712,200
47F4.49,0004.964,4003.516,100
95F4.49,0005.713,7003.4913,700
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,169
Energy cost-
Total cost-
Cooper & Hunter 6k BTU Wall Mount
$1,369 at MiniSplitWarehouse
C&H R-410A
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
5F2.097,5001.812,1052.198,581
17F2.98,5002.292,1082.4510,041
47F3.957,0004.353,5653.7313,241
95F4.636,0002.613,3883.7512,402
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,369
Energy cost-
Total cost-
Fujitsu AirStage H-Series 18k BTU Ceiling Cassette
$4,904 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-5.0F4.641,900--2.0614,400
5F2.2817,1004.882,0002.2817,100
17F3.0114,4005.132,1002.4219,300
47F3.8121,6006.493,1002.6124,000
95F4.018,0005.053,1003.0420,100
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$4,904
Energy cost-
Total cost-
Midea DLC-series 18k BTU Wall Mount
$2,731 at MiniSplitWarehouse
MIDEA R-410A
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
5F2.8924,0001.353,5892.8924,000
17F2.8920,2001.835,1251.9824,485
47F4.2820,0003.588,6733.3630,995
95F4.4718,0003.718,2363.2926,934
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,731
Energy cost-
Total cost-
Cooper & Hunter CH Series 9k BTU Floor Mount
$1,577 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-13.0F0.84800--1.424,600
5F2.278,6001.781,7002.278,600
17F2.99,0003.353,2002.499,600
47F4.329,0005.545,1003.3812,700
95F4.719,0005.864,0003.8612,900
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,577
Energy cost-
Total cost-
Gree Pular 9k BTU Wall Mount
$2,103 at HVACDirect
GREE R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.391,800--1.426,000
5F1.889,5002.542,6001.889,500
17F2.938,8003.042,7002.0811,000
47F3.910,5004.672,3882.8214,600
95F4.379,1004.212,7303.513,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,103
Energy cost-
Total cost-
Durastar DRA Series 9k BTU Wall Mount
$1,492 at GotDuctless
DURASTAR R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.072,000--1.245,800
5F1.811,5001.84,0001.811,500
17F2.5910,0002.345,2001.7512,800
47F3.6312,0005.573,8003.316,000
95F4.49,0008.793,6003.3513,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,492
Energy cost-
Total cost-
Cooper & Hunter CH Series 9k BTU Wall Mount
$1,419 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.072,000--1.245,800
5F1.811,5001.84,0001.811,500
17F2.5910,0002.345,2001.7512,800
47F3.6312,0005.573,8003.316,000
95F4.49,0008.793,6003.3513,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,419
Energy cost-
Total cost-
Cooper & Hunter CH Series 9k BTU Wall Mount
$1,419 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.072,000--1.245,800
5F1.811,5001.84,0001.811,500
17F2.5910,0002.345,2001.7512,800
47F3.6312,0005.573,8003.316,000
95F4.49,0008.793,6003.3513,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,419
Energy cost-
Total cost-
Durastar DRA Series 9k BTU Floor Mount
$1,757 at GotDuctless
DURASTAR R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-13.0F0.84800--1.424,600
5F2.278,6001.781,7002.278,600
17F2.99,0003.353,2002.499,600
47F4.329,0005.545,1003.3812,700
95F4.719,0005.864,0003.8612,900
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,757
Energy cost-
Total cost-
Midea D5F Series 9k BTU Floor Mount
$1,579 at MiniSplitWarehouse
MIDEA R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-13.0F0.84800--1.424,600
5F2.278,6001.781,7002.278,600
17F2.99,0003.353,2002.499,600
47F4.329,0005.545,1003.3812,700
95F4.89,0005.864,0003.8612,900
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,579
Energy cost-
Total cost-
Gree Pular 22k BTU Wall Mount
$3,394 at HVACDirect
GREE R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-30.0F1.522,600--2.4914,000
5F2.1319,0002.493,4002.1319,000
17F2.720,0003.45,5702.1122,000
47F3.824,0004.54,3003.1833,600
95F4.022,0004.663,3402.9528,660
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,394
Energy cost-
Total cost-
Mitsubishi Electric M-Series 15k BTU Wall Mount
$3,633 (2 stores)
MITSUBISHI ELECTRIC R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-10.0F1.812,720--1.8216,500
5F2.0622,2002.153,6602.0622,200
17F3.0810,6002.14,3702.126,500
47F4.4816,5005.395,1503.1628,400
95F4.3115,0004.173,7002.5419,100
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,633
Energy cost-
Total cost-
Carrier 45M Series 18k BTU Wall Mount
$4,600 at HVACDirect
CARRIER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F0.982,400--1.4511,900
5F2.3422,6001.969,3002.3422,600
17F3.0119,3002.2611,5002.3523,200
47F4.4120,0005.369,7003.5729,700
95F4.418,0003.9312,6003.5927,900
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$4,600
Energy cost-
Total cost-
Carrier 45M Series 6k BTU Wall Mount
$2,300 at HVACDirect
CARRIER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.092,300--1.233,200
5F2.47,7001.793,6002.47,700
17F2.797,9002.495,1002.388,600
47F4.197,0003.663,0002.9611,000
95F5.336,0003.972,3003.8912,600
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,300
Energy cost-
Total cost-
Mitsubishi Electric M-Series 12k BTU Wall Mount
$2,936 (2 stores)
MITSUBISHI ELECTRIC R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-10.0F0.951,130--0.938,160
5F1.812,3001.421,7001.812,300
17F2.727,6001.852,2101.8516,000
47F3.9212,3003.873,3002.2419,100
95F3.9112,0002.121,3002.1514,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,936
Energy cost-
Total cost-
Mitsubishi Electric M-Series 12k BTU Wall Mount
$2,643 (2 stores)
MITSUBISHI ELECTRIC R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-10.0F1.24550--1.266,780
5F1.810,1001.637801.810,100
17F2.649,0002.059802.1112,000
47F3.8414,4004.01,5002.9818,100
95F3.9112,0004.231,3002.7514,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,643
Energy cost-
Total cost-
Mitsubishi Electric M-Series 17k BTU Wall Mount
$4,230 (2 stores)
MITSUBISHI ELECTRIC R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-10.0F1.842,760--1.8317,500
5F2.0623,6002.063,7302.0623,600
17F3.012,7002.144,4502.1628,200
47F3.5817,0005.395,1503.0630,200
95F3.8217,2004.173,7002.6721,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$4,230
Energy cost-
Total cost-
Gree Floor ceiling 9k BTU Floor/Ceiling Console
$3,159 at HVACDirect
GREE R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.171,600--1.176,000
5F1.910,5002.052,8001.910,500
17F2.968,9002.344,0001.9813,000
47F4.110,5005.132,8003.1815,500
95F4.179,1007.332,5003.4511,900
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,159
Energy cost-
Total cost-
Fujitsu AirStage H-Series 18k BTU Wall Mount
$4,036 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-15.0F3.13,700--1.6519,110
5F2.0824,8003.575,0002.0225,400
17F3.3213,6003.725,2002.327,200
47F4.3721,6005.458,0003.2131,800
95F4.0918,0005.137,0003.1326,200
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$4,036
Energy cost-
Total cost-
Carrier 45M Series 12k BTU Wall Mount
$2,700 at HVACDirect
CARRIER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.172,000--1.255,900
5F1.811,5001.724,1001.811,500
17F2.719,8002.225,3001.7512,800
47F3.7412,0004.843,8003.3516,000
95F3.9512,0008.573,8003.3513,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,700
Energy cost-
Total cost-
ACiQ 12k BTU Wall Mount
$1,650 at HVACDirect
ACIQ R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.172,000--1.255,900
5F1.811,5001.724,1001.811,500
17F2.719,8002.225,3001.7512,800
47F3.7412,0004.843,8003.3516,000
95F3.9112,0008.573,8003.3513,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,650
Energy cost-
Total cost-
Senville SENA Series 12k BTU Wall Mount
$1,400 at Amazon
SENVILLE R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.172,000--1.255,900
5F1.811,5001.724,1001.811,500
17F2.719,8002.225,3001.7512,800
47F3.7412,0004.843,8003.3516,000
95F3.9112,0008.573,8003.3513,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,400
Energy cost-
Total cost-
Cooper & Hunter CH Series 6k BTU Wall Mount
$1,339 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.092,300--1.223,900
5F2.297,5001.653,1002.297,500
17F2.57,6002.13,8002.048,700
47F3.87,0004.943,2002.6110,700
95F4.636,0004.882,5003.6211,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,339
Energy cost-
Total cost-
Durastar DRA Series 6k BTU Wall Mount
$1,056 at GotDuctless
DURASTAR R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.092,300--1.223,900
5F2.297,5001.653,1002.297,500
17F2.57,6002.13,8002.048,700
47F3.87,0004.943,2002.6110,700
95F4.636,0004.882,5003.6211,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,056
Energy cost-
Total cost-

Frequently Asked Questions

How does altitude affect heat pump performance?

At Denver's 5,280 feet, air is about 17% less dense than at sea level. Less dense air means less heat transfer per cycle, typically reducing capacity by 5-15%. Variable-speed compressors compensate better because they can ramp up to make up the difference. The capacity numbers in the tool are at sea-level conditions, so plan for about 10% less at Denver altitude. Not a dealbreaker, just something to account for when sizing.

Does dry climate help heat pumps?

Yes, and it's a real advantage that rarely gets mentioned. In humid climates, heat pumps spend a lot of time in defrost mode — reversing the cycle to melt frost off the outdoor coil, which temporarily stops heating. Denver's dry air means way less frost, so the unit runs in heating mode more consistently. You also don't need dehumidification features for cooling, which simplifies model selection. Real-world performance in the Mountain West tends to beat the published ratings.

What about the big temperature swings?

This is exactly where variable-speed models shine. They modulate output smoothly to match whatever the temperature is doing, instead of just cycling on and off. On a mild 50°F spring day, a variable-speed unit runs at maybe 30-40% capacity, quietly and efficiently. When a cold snap drops things to -5°F that night, it ramps to full power. Single-stage units can only do on or off, which wastes energy during the shoulder seasons that make up a lot of the Mountain West year.

Can a heat pump compete with cheap Colorado gas?

Colorado gas prices are among the cheapest in the country, which makes this a tighter call than in the Northeast. But a heat pump doesn't have to beat gas at every temperature — it just needs to win for enough hours. Above about 30°F, a decent heat pump crushes gas on efficiency, and Denver has a lot of hours above 30°F. Dual-fuel (heat pump primary, gas backup for the coldest nights) is popular and practical for the Front Range. Enter your rates in the tool to see the full-year comparison.

Browse all heat pumps | ACIQ | AMERICAN STANDARD / MITSUBISHI ELECTRIC | BOSCH | CARRIER | COOPER&HUNTER | DAIKIN | DURASTAR | FUJITSU | GREE | INNOVAIR | LG | MIDEA | MITSUBISHI ELECTRIC | MRCOOL | SENVILLE | STEALTH | STEALTH | STEALTH | WESTINGHOUSE