Heat Pumps for the Pacific Northwest

The Pacific Northwest has the cheapest electricity in the country at $0.12/kWh and mild winters — that's basically the ideal climate for a heat pump. Most models work well here, so the decision comes down to price and features rather than cold-weather survival. This tool calculates total 10-year cost for every model using Seattle-area weather data. Set your location for results from your nearest weather station.

772 heat pumps match this filter. Showing top 50 by SEER2.

NameBrandRefrigerantPerformanceOperation
Carrier 45M Series 6k BTU Wall Mount
$3,400 at HVACDirect
CARRIER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.144,100--1.297,500
5F2.013,5001.159002.013,500
17F2.4111,0001.951,6002.2614,600
47F4.09,0005.864,0003.1917,200
95F5.176,0005.053,1003.516,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,400
Energy cost-
Total cost-
Mitsubishi Electric M-Series 6k BTU Wall Mount
$2,492 (2 stores)
MITSUBISHI ELECTRIC R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-10.0F1.98810--1.939,000
5F2.3812,6002.391,1402.3812,600
17F3.456,0002.741,3102.6914,400
47F4.889,0004.151,7003.3120,000
95F6.286,0004.151,7003.3114,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,492
Energy cost-
Total cost-
Fujitsu AirStage H-Series 9k BTU Wall Mount
$3,127 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F2.811,340--1.7713,200
5F2.4817,0003.321,7002.4817,000
17F3.747,4004.192,0002.6119,500
47F5.4112,0006.043,3003.0724,000
95F5.619,0007.573,1004.0515,200
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,127
Energy cost-
Total cost-
Carrier 45M Series 9k BTU Wall Mount
$3,600 at HVACDirect
CARRIER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.144,100--1.297,500
5F2.013,5001.159002.013,500
17F2.4111,0001.951,6002.2614,600
47F3.5912,0005.864,0003.1917,200
95F4.989,0005.053,1003.516,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,600
Energy cost-
Total cost-
Mitsubishi Electric M-Series 9k BTU Wall Mount
$2,811 (2 stores)
MITSUBISHI ELECTRIC R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-10.0F2.051,470--2.0112,000
5F2.214,7002.21,8002.214,700
17F3.477,7002.442,0002.3916,300
47F4.9512,0005.053,1002.9321,300
95F5.389,0004.582,5002.7815,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,811
Energy cost-
Total cost-
Fujitsu AirStage H-Series 9k BTU Wall Mount
$2,786 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-15.0F2.231,370--1.711,400
5F2.2615,4003.091,9002.2615,400
17F3.67,5003.392,2002.4917,500
47F5.3312,0005.133,5003.0823,000
95F5.59,0008.263,1003.9812,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,786
Energy cost-
Total cost-
Fujitsu AirStage H-Series 12k BTU Wall Mount
$3,396 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F3.091,900--1.7615,300
5F2.6216,2003.862,5002.1820,500
17F3.479,6004.722,9002.5922,800
47F4.8715,3006.284,5003.5927,300
95F4.8812,0007.573,1003.8417,300
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,396
Energy cost-
Total cost-
Fujitsu AirStage H-Series 12k BTU Wall Mount
$3,051 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-15.0F2.741,400--1.8112,200
5F2.1616,6003.361,9502.1616,600
17F3.4510,0003.392,2002.4418,700
47F4.6416,0005.133,5003.0723,600
95F4.6912,0008.263,1003.8416,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,051
Energy cost-
Total cost-
Gree Airy 9k BTU Wall Mount
$2,932 at HVACDirect
GREE R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F4.232,600--1.647,400
5F2.1111,5004.232,6002.1111,500
17F3.228,9004.322,8002.0613,000
47F4.4410,6005.282,7003.7516,000
95F4.949,1008.372,0003.1614,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,932
Energy cost-
Total cost-
Fujitsu AirStage H-Series 9k BTU Wall Mount
$2,156 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
5F2.3210,3002.552,0002.3210,300
17F3.247,4002.931,7002.6212,600
47F4.6312,0005.862,8002.6414,500
95F4.89,0006.993,1003.7712,100
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,156
Energy cost-
Total cost-
Mitsubishi Electric M-Series 12k BTU Wall Mount
$3,158 (2 stores)
MITSUBISHI ELECTRIC R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-10.0F2.011,510--2.0113,200
5F2.216,2002.261,8502.216,200
17F3.419,3002.542,0802.4918,200
47F4.213,2005.053,1003.2223,500
95F4.5112,0004.582,5002.8416,100
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,158
Energy cost-
Total cost-
Carrier 45M Series 12k BTU Wall Mount
$3,900 at HVACDirect
CARRIER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.144,100--1.297,500
5F2.013,5001.159002.013,500
17F2.4111,0001.951,6002.2614,600
47F3.5912,0005.864,0003.1917,200
95F4.1912,0005.053,1003.516,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,900
Energy cost-
Total cost-
Gree Airy 12k BTU Wall Mount
$3,114 at HVACDirect
GREE R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F4.232,600--1.758,500
5F2.012,2004.232,6002.012,200
17F3.1110,3004.322,8002.0613,000
47F4.5312,2005.043,2703.7716,200
95F4.4512,00010.622,9003.8317,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,114
Energy cost-
Total cost-
Fujitsu AirStage H-Series 14k BTU Wall Mount
$3,674 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F3.452,000--1.7217,400
5F2.5418,4003.962,7002.023,500
17F3.4410,8004.562,8002.2924,300
47F4.7217,4006.284,5003.5728,000
95F4.5214,5007.143,9003.4919,400
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,674
Energy cost-
Total cost-
Mitsubishi Electric M-Series 9k BTU Wall Mount
$2,465 (2 stores)
MITSUBISHI ELECTRIC R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-10.0F1.96670--1.957,450
5F1.89,6002.298601.89,600
17F2.665,9002.321,0302.3911,500
47F4.859,6005.693,3002.6615,900
95F4.559,0004.473,2003.4112,200
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,465
Energy cost-
Total cost-
Mitsubishi Electric M-Series 9k BTU Wall Mount
$1,940 (2 stores)
MITSUBISHI ELECTRIC R-410A
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-4.0F2.121,230--2.086,180
5F2.127,9002.11,5802.127,900
17F2.616,5002.392,0402.4310,200
47F4.4410,9005.734,5002.6815,900
95F4.559,0004.43,6003.4112,200
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,940
Energy cost-
Total cost-
Mitsubishi Electric M-Series 9k BTU Wall Mount
$2,241 (2 stores)
MITSUBISHI ELECTRIC R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-10.0F1.41480--1.435,330
5F1.88,1001.867001.88,100
17F2.696,7002.229102.1510,200
47F4.4410,9005.693,3002.6815,900
95F4.559,0004.473,2003.4112,200
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,241
Energy cost-
Total cost-
Gree Airy 18k BTU Wall Mount
$4,101 at HVACDirect
GREE R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F2.145,100--1.2310,800
5F1.818,0002.496,8001.818,000
17F2.8615,5002.618,0001.920,100
47F4.0118,6005.235,0003.2423,000
95F4.1918,0006.014,1003.1925,590
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$4,101
Energy cost-
Total cost-
Fujitsu AirStage H-Series 12k BTU Wall Mount
$2,374 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
5F2.3910,6002.552,0002.3910,600
17F3.118,7002.931,7002.6513,200
47F4.3214,0005.862,8002.515,000
95F3.9512,0006.993,1003.2613,800
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,374
Energy cost-
Total cost-
Fujitsu AirStage H-Series 14k BTU Wall Mount
$3,274 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-15.0F0.661,900--1.9216,400
5F2.121,0003.492,5002.121,000
17F3.4411,4003.812,6002.3522,000
47F4.5918,0005.074,1503.2625,000
95F4.3414,5006.063,1003.2819,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,274
Energy cost-
Total cost-
Carrier 45M Series 9k BTU Wall Mount
$2,560 at HVACDirect
CARRIER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.172,000--1.115,100
5F1.811,5001.724,1001.811,500
17F2.719,8002.225,3001.7512,800
47F3.7412,0004.843,8003.3516,000
95F4.559,0008.573,8003.3513,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,560
Energy cost-
Total cost-
ACiQ 9k BTU Wall Mount
$1,495 at HVACDirect
ACIQ R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.172,000--1.115,100
5F1.811,5001.724,1001.811,500
17F2.719,8002.225,3001.7512,800
47F3.7412,0004.843,8003.3516,000
95F4.559,0008.573,8003.3513,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,495
Energy cost-
Total cost-
Senville SENA Series 9k BTU Wall Mount
$1,300 at Amazon
SENVILLE R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.172,000--1.115,100
5F1.811,5001.724,1001.811,500
17F2.719,8002.225,3001.7512,800
47F3.7412,0004.843,8003.3516,000
95F4.559,0008.573,8003.3513,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,300
Energy cost-
Total cost-
Daikin 9k BTU Wall Mount
$2,063 (3 stores)
DAIKIN R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-13.0F3.742,300--1.8310,000
5F1.811,0003.742,3002.011,000
17F3.176,6004.322,8002.3313,200
47F4.6111,0006.144,4003.2215,700
95F4.89,0004.784,4004.2612,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,063
Energy cost-
Total cost-
Cooper & Hunter CH Series 9k BTU Floor Mount
$1,698 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.042,700--1.024,700
5F1.8411,3001.832,0001.8411,300
17F2.719,8002.492,8002.1712,200
47F4.49,0004.964,4003.516,100
95F4.49,0005.713,7003.4913,700
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,698
Energy cost-
Total cost-
ACiQ 9k BTU Floor Mount
$1,900 at HVACDirect
ACIQ R454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.042,700--1.024,700
5F1.8411,3001.832,0001.8411,300
17F2.719,8002.492,8002.1712,200
47F4.49,0004.964,4003.516,100
95F4.49,0005.713,7003.4913,700
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,900
Energy cost-
Total cost-
Durastar DRA Series 9k BTU Floor Mount
$2,169 at GotDuctless
DURASTAR R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.042,700--1.024,700
5F1.8411,3001.832,0001.8411,300
17F2.719,8002.492,8002.1712,200
47F4.49,0004.964,4003.516,100
95F4.49,0005.713,7003.4913,700
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,169
Energy cost-
Total cost-
Gree Airy 22k BTU Wall Mount
$4,318 at HVACDirect
GREE R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-20.0F2.291,720--1.6217,000
5F1.824,0002.493,4001.824,000
17F2.9520,0003.215,8001.9424,000
47F3.9124,0004.055,8003.232,000
95F4.1122,0004.436,8003.331,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$4,318
Energy cost-
Total cost-
Cooper & Hunter 6k BTU Wall Mount
$1,369 at MiniSplitWarehouse
C&H R-410A
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
5F2.097,5001.812,1052.198,581
17F2.98,5002.292,1082.4510,041
47F3.957,0004.353,5653.7313,241
95F4.636,0002.613,3883.7512,402
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,369
Energy cost-
Total cost-
Fujitsu AirStage H-Series 18k BTU Ceiling Cassette
$4,904 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-5.0F4.641,900--2.0614,400
5F2.2817,1004.882,0002.2817,100
17F3.0114,4005.132,1002.4219,300
47F3.8121,6006.493,1002.6124,000
95F4.018,0005.053,1003.0420,100
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$4,904
Energy cost-
Total cost-
Midea DLC-series 18k BTU Wall Mount
$2,731 at MiniSplitWarehouse
MIDEA R-410A
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
5F2.8924,0001.353,5892.8924,000
17F2.8920,2001.835,1251.9824,485
47F4.2820,0003.588,6733.3630,995
95F4.4718,0003.718,2363.2926,934
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,731
Energy cost-
Total cost-
Cooper & Hunter CH Series 9k BTU Floor Mount
$1,577 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-13.0F0.84800--1.424,600
5F2.278,6001.781,7002.278,600
17F2.99,0003.353,2002.499,600
47F4.329,0005.545,1003.3812,700
95F4.719,0005.864,0003.8612,900
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,577
Energy cost-
Total cost-
Gree Pular 9k BTU Wall Mount
$2,103 at HVACDirect
GREE R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.391,800--1.426,000
5F1.889,5002.542,6001.889,500
17F2.938,8003.042,7002.0811,000
47F3.910,5004.672,3882.8214,600
95F4.379,1004.212,7303.513,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,103
Energy cost-
Total cost-
Durastar DRA Series 9k BTU Wall Mount
$1,492 at GotDuctless
DURASTAR R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.072,000--1.245,800
5F1.811,5001.84,0001.811,500
17F2.5910,0002.345,2001.7512,800
47F3.6312,0005.573,8003.316,000
95F4.49,0008.793,6003.3513,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,492
Energy cost-
Total cost-
Cooper & Hunter CH Series 9k BTU Wall Mount
$1,419 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.072,000--1.245,800
5F1.811,5001.84,0001.811,500
17F2.5910,0002.345,2001.7512,800
47F3.6312,0005.573,8003.316,000
95F4.49,0008.793,6003.3513,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,419
Energy cost-
Total cost-
Cooper & Hunter CH Series 9k BTU Wall Mount
$1,419 at MiniSplitWarehouse
COOPER&HUNTER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.072,000--1.245,800
5F1.811,5001.84,0001.811,500
17F2.5910,0002.345,2001.7512,800
47F3.6312,0005.573,8003.316,000
95F4.49,0008.793,6003.3513,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,419
Energy cost-
Total cost-
Fujitsu AirStage H-Series 9k BTU Wall Mount
$1,568 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
5F2.297,1002.641,8002.297,100
17F3.076,4003.212,3002.649,000
47F4.1910,0006.392,4003.3813,600
95F3.669,0007.573,1002.911,200
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,568
Energy cost-
Total cost-
Durastar DRA Series 9k BTU Floor Mount
$1,757 at GotDuctless
DURASTAR R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-13.0F0.84800--1.424,600
5F2.278,6001.781,7002.278,600
17F2.99,0003.353,2002.499,600
47F4.329,0005.545,1003.3812,700
95F4.719,0005.864,0003.8612,900
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,757
Energy cost-
Total cost-
Midea D5F Series 9k BTU Floor Mount
$1,579 at MiniSplitWarehouse
MIDEA R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-13.0F0.84800--1.424,600
5F2.278,6001.781,7002.278,600
17F2.99,0003.353,2002.499,600
47F4.329,0005.545,1003.3812,700
95F4.89,0005.864,0003.8612,900
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,579
Energy cost-
Total cost-
Gree Pular 22k BTU Wall Mount
$3,394 at HVACDirect
GREE R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-30.0F1.522,600--2.4914,000
5F2.1319,0002.493,4002.1319,000
17F2.720,0003.45,5702.1122,000
47F3.824,0004.54,3003.1833,600
95F4.022,0004.663,3402.9528,660
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,394
Energy cost-
Total cost-
Mitsubishi Electric M-Series 15k BTU Wall Mount
$3,633 (2 stores)
MITSUBISHI ELECTRIC R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-10.0F1.812,720--1.8216,500
5F2.0622,2002.153,6602.0622,200
17F3.0810,6002.14,3702.126,500
47F4.4816,5005.395,1503.1628,400
95F4.3115,0004.173,7002.5419,100
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,633
Energy cost-
Total cost-
Carrier 45M Series 18k BTU Wall Mount
$4,600 at HVACDirect
CARRIER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F0.982,400--1.4511,900
5F2.3422,6001.969,3002.3422,600
17F3.0119,3002.2611,5002.3523,200
47F4.4120,0005.369,7003.5729,700
95F4.418,0003.9312,6003.5927,900
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$4,600
Energy cost-
Total cost-
Carrier 45M Series 6k BTU Wall Mount
$2,300 at HVACDirect
CARRIER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.092,300--1.233,200
5F2.47,7001.793,6002.47,700
17F2.797,9002.495,1002.388,600
47F4.197,0003.663,0002.9611,000
95F5.336,0003.972,3003.8912,600
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,300
Energy cost-
Total cost-
Mitsubishi Electric M-Series 12k BTU Wall Mount
$2,936 (2 stores)
MITSUBISHI ELECTRIC R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-10.0F0.951,130--0.938,160
5F1.812,3001.421,7001.812,300
17F2.727,6001.852,2101.8516,000
47F3.9212,3003.873,3002.2419,100
95F3.9112,0002.121,3002.1514,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,936
Energy cost-
Total cost-
Mitsubishi Electric M-Series 12k BTU Wall Mount
$2,643 (2 stores)
MITSUBISHI ELECTRIC R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-10.0F1.24550--1.266,780
5F1.810,1001.637801.810,100
17F2.649,0002.059802.1112,000
47F3.8414,4004.01,5002.9818,100
95F3.9112,0004.231,3002.7514,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,643
Energy cost-
Total cost-
Mitsubishi Electric M-Series 17k BTU Wall Mount
$4,230 (2 stores)
MITSUBISHI ELECTRIC R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-10.0F1.842,760--1.8317,500
5F2.0623,6002.063,7302.0623,600
17F3.012,7002.144,4502.1628,200
47F3.5817,0005.395,1503.0630,200
95F3.8217,2004.173,7002.6721,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$4,230
Energy cost-
Total cost-
Gree Floor ceiling 9k BTU Floor/Ceiling Console
$3,159 at HVACDirect
GREE R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.171,600--1.176,000
5F1.910,5002.052,8001.910,500
17F2.968,9002.344,0001.9813,000
47F4.110,5005.132,8003.1815,500
95F4.179,1007.332,5003.4511,900
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,159
Energy cost-
Total cost-
Fujitsu AirStage H-Series 18k BTU Wall Mount
$4,036 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-15.0F3.13,700--1.6519,110
5F2.0824,8003.575,0002.0225,400
17F3.3213,6003.725,2002.327,200
47F4.3721,6005.458,0003.2131,800
95F4.0918,0005.137,0003.1326,200
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$4,036
Energy cost-
Total cost-
Carrier 45M Series 12k BTU Wall Mount
$2,700 at HVACDirect
CARRIER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.172,000--1.255,900
5F1.811,5001.724,1001.811,500
17F2.719,8002.225,3001.7512,800
47F3.7412,0004.843,8003.3516,000
95F3.9512,0008.573,8003.3513,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,700
Energy cost-
Total cost-
ACiQ 12k BTU Wall Mount
$1,650 at HVACDirect
ACIQ R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.172,000--1.255,900
5F1.811,5001.724,1001.811,500
17F2.719,8002.225,3001.7512,800
47F3.7412,0004.843,8003.3516,000
95F3.9112,0008.573,8003.3513,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,650
Energy cost-
Total cost-

Frequently Asked Questions

How much will I save replacing baseboard heat?

A lot. Baseboard runs at COP 1.0 — every watt of electricity becomes exactly one watt of heat. A heat pump at COP 3.0 (normal for Seattle's mild winters) gives you 3 watts of heat for every 1 watt of electricity. That's a 67% reduction in heating electricity. Enter your location and home details in the tool above for exact savings with your weather data. For most Seattle homes, payback is 3-5 years.

Do I need a cold-climate model for Seattle?

Probably not. Seattle's design temperature is around 21°F, and sustained temps below 20°F are rare. A standard heat pump handles that fine, which opens up a wider range of models at lower prices. If you're in the Cascades, eastern Washington, or anywhere that regularly sees single digits, then yes — get a cold-climate model. But for the Puget Sound area, a standard unit is plenty.

What about heat dome events — can a heat pump handle 110°F?

Yes — a heat pump in cooling mode is just an air conditioner. After the 2021 heat dome (108°F in Portland), a lot of people realized they needed cooling for the first time. A heat pump solves both problems at once: efficient heating to replace your baseboard, plus AC for increasingly frequent extreme heat events. Even a single mini split for your main living area makes a huge difference during a heat dome.

Mini split or ducted for a PNW home?

Most older PNW homes were built for baseboard and don't have ductwork, making mini splits the natural fit. They install without ductwork and provide both heating and cooling per zone. Mini splits in the database average SEER2 of 20.9 versus 18.4 for ducted, so they're more efficient too. For newer homes that already have forced-air ducts, a ducted heat pump reuses that infrastructure. But for the typical 1960s Seattle rambler with baseboard? Mini splits all the way.

Browse all heat pumps | ACIQ | AMERICAN STANDARD / MITSUBISHI ELECTRIC | BOSCH | CARRIER | COOPER&HUNTER | DAIKIN | DURASTAR | FUJITSU | GREE | INNOVAIR | LG | MIDEA | MITSUBISHI ELECTRIC | MRCOOL | SENVILLE | STEALTH | STEALTH | STEALTH | WESTINGHOUSE