ACiQ 60k BTU Multi-Zone
$5,800
at HVACDirect
|
ACIQ |
R454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 1.85 | 12,000 | - | - | 1.7 | 27,800 |
| 5F | 2.2 | 39,000 | 2.01 | 13,000 | 2.2 | 39,000 |
| 17F | 2.8 | 39,000 | 2.93 | 18,000 | 2.4 | 42,000 |
| 47F | 3.7 | 60,000 | 4.88 | 20,000 | 3.38 | 60,000 |
| 95F | 2.93 | 60,000 | 4.64 | 19,000 | 3.03 | 62,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $5,800 |
| Energy cost | - |
| Total cost | - |
|
LG Multi F Max 56k BTU Multi-Zone
$7,430
at HVACDirect
|
LG |
R-32 |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -4.0F | 2.84 | 14,035 | - | - | 2.1 | 45,200 |
| 5F | 3.1 | 46,000 | 3.0 | 15,255 | 2.34 | 52,500 |
| 17F | 2.55 | 42,000 | 3.23 | 16,950 | 2.68 | 56,500 |
| 47F | 3.45 | 64,000 | 5.13 | 12,420 | 3.4 | 68,000 |
| 95F | 3.51 | 56,000 | 4.95 | 10,800 | 3.28 | 65,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $7,430 |
| Energy cost | - |
| Total cost | - |
|
Cooper & Hunter 54k BTU Ceiling Cassette
$4,464
at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 1.59 | 6,300 | - | - | 1.53 | 23,300 |
| 5F | 2.01 | 35,000 | 2.08 | 9,500 | 2.01 | 35,000 |
| 17F | 2.53 | 37,200 | 2.71 | 12,500 | 2.22 | 45,300 |
| 47F | 3.05 | 60,000 | 5.15 | 20,200 | 3.05 | 60,000 |
| 95F | 2.79 | 54,000 | 3.14 | 15,000 | 2.64 | 54,500 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $4,464 |
| Energy cost | - |
| Total cost | - |
|
LG Multi F Max 60k BTU Multi-Zone Ducted
$9,062
at HVACDirect
|
LG |
R-32 |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -4.0F | 2.8 | 14,035 | - | - | 2.09 | 45,200 |
| 5F | 2.99 | 45,000 | 2.96 | 15,255 | 2.33 | 52,500 |
| 17F | 2.62 | 40,000 | 3.18 | 16,950 | 2.65 | 56,500 |
| 47F | 3.33 | 64,000 | 4.61 | 12,420 | 3.33 | 68,000 |
| 95F | 3.23 | 60,000 | 4.52 | 10,800 | 3.22 | 64,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $9,062 |
| Energy cost | - |
| Total cost | - |
|
Cooper & Hunter CH Series 54k BTU Floor Mount
$5,480
at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 0.57 | 2,300 | - | - | 1.46 | 29,700 |
| 5F | 1.91 | 54,000 | 2.08 | 9,500 | 1.91 | 54,000 |
| 17F | 2.33 | 41,000 | 2.69 | 12,400 | 2.17 | 58,000 |
| 47F | 3.02 | 60,000 | 5.13 | 21,700 | 3.2 | 65,500 |
| 95F | 2.64 | 54,000 | 2.93 | 20,000 | 2.62 | 54,500 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $5,480 |
| Energy cost | - |
| Total cost | - |
|
ACiQ 54k BTU Floor Mount
$5,348
at HVACDirect
|
ACIQ |
R454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 0.57 | 2,300 | - | - | 1.46 | 29,700 |
| 5F | 1.91 | 54,000 | 2.08 | 9,500 | 1.91 | 54,000 |
| 17F | 2.33 | 41,000 | 2.69 | 12,400 | 2.17 | 58,000 |
| 47F | 3.02 | 60,000 | 5.13 | 21,700 | 3.2 | 65,500 |
| 95F | 2.64 | 54,000 | 2.93 | 20,000 | 2.62 | 54,500 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $5,348 |
| Energy cost | - |
| Total cost | - |
|
ACiQ 60k BTU Multi-Zone Ducted
$6,700
at HVACDirect
|
ACIQ |
R454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 1.85 | 12,000 | - | - | 1.47 | 24,000 |
| 5F | 2.1 | 40,000 | 2.01 | 13,000 | 2.1 | 40,000 |
| 17F | 2.6 | 39,000 | 2.93 | 18,000 | 2.3 | 41,000 |
| 47F | 3.7 | 60,000 | 4.88 | 20,000 | 3.44 | 61,000 |
| 95F | 2.93 | 60,000 | 4.64 | 19,000 | 2.81 | 61,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $6,700 |
| Energy cost | - |
| Total cost | - |
|
MRCOOL UHP Series 54k BTU Central Ducted
$5,281
at HVACDirect
|
MRCOOL |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.53 | 11,600 | - | - | 1.69 | 37,300 |
| 5F | 1.9 | 54,000 | 2.15 | 15,400 | 1.9 | 54,000 |
| 17F | 2.5 | 35,000 | 2.6 | 16,500 | 2.29 | 54,000 |
| 47F | 3.36 | 55,000 | 3.23 | 8,600 | 3.08 | 60,000 |
| 95F | 3.52 | 54,000 | 2.18 | 11,400 | 2.62 | 60,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $5,281 |
| Energy cost | - |
| Total cost | - |
|
ACiQ 54k BTU Central Ducted
$6,700
at HVACDirect
|
ACIQ |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.53 | 11,600 | - | - | 1.69 | 37,300 |
| 5F | 1.9 | 54,000 | 2.15 | 15,400 | 1.9 | 54,000 |
| 17F | 2.5 | 35,000 | 2.6 | 16,500 | 2.29 | 54,000 |
| 47F | 3.36 | 55,000 | 3.23 | 8,600 | 3.08 | 60,000 |
| 95F | 3.52 | 54,000 | 2.18 | 11,400 | 2.62 | 60,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $6,700 |
| Energy cost | - |
| Total cost | - |
|
Midea D5F Series 54k BTU Central Ducted
$6,659
at MiniSplitWarehouse
|
MIDEA |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.53 | 11,600 | - | - | 1.69 | 37,300 |
| 5F | 1.9 | 54,000 | 2.15 | 15,400 | 1.9 | 54,000 |
| 17F | 2.5 | 35,000 | 2.6 | 16,500 | 2.29 | 54,000 |
| 47F | 3.36 | 55,000 | 3.23 | 8,600 | 3.08 | 60,000 |
| 95F | 3.52 | 54,000 | 2.18 | 11,400 | 2.62 | 60,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $6,659 |
| Energy cost | - |
| Total cost | - |
|
Cooper & Hunter 58k BTU Compact Ducted
$4,783
at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 1.33 | 6,200 | - | - | 1.63 | 24,200 |
| 5F | 2.2 | 40,000 | 2.06 | 10,200 | 2.2 | 40,000 |
| 17F | 2.66 | 40,000 | 2.17 | 11,100 | 2.45 | 41,500 |
| 47F | 3.7 | 60,000 | 4.43 | 11,800 | 3.8 | 67,000 |
| 95F | 2.93 | 58,000 | 3.57 | 14,600 | 2.72 | 63,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $4,783 |
| Energy cost | - |
| Total cost | - |
|
Midea D5F Series 58k BTU Compact Ducted
$6,499
at MiniSplitWarehouse
|
MIDEA |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 1.33 | 6,200 | - | - | 1.63 | 24,200 |
| 5F | 2.2 | 40,000 | 2.06 | 10,200 | 2.2 | 40,000 |
| 17F | 2.66 | 40,000 | 2.17 | 11,100 | 2.45 | 41,500 |
| 47F | 3.7 | 60,000 | 4.43 | 11,800 | 3.8 | 67,000 |
| 95F | 2.93 | 58,000 | 3.57 | 14,600 | 2.72 | 63,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $6,499 |
| Energy cost | - |
| Total cost | - |
|
Cooper & Hunter 55k BTU Central Ducted
$4,880
at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 1.32 | 12,000 | - | - | 1.28 | 21,300 |
| 5F | 1.9 | 35,400 | 2.2 | 19,100 | 1.9 | 35,400 |
| 17F | 2.6 | 40,500 | 2.75 | 19,900 | 2.2 | 41,500 |
| 47F | 3.44 | 59,000 | 4.45 | 11,700 | 3.35 | 60,500 |
| 95F | 2.78 | 55,000 | 3.85 | 21,800 | 2.68 | 57,500 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $4,880 |
| Energy cost | - |
| Total cost | - |
|
Stealth EZ Series 54k BTU Central Ducted
$4,577
at HVACDirect
|
STEALTH |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 0.86 | 6,700 | - | - | 1.46 | 30,900 |
| 5F | 1.8 | 52,000 | 1.72 | 14,200 | 1.8 | 52,000 |
| 17F | 2.4 | 45,000 | 2.61 | 16,400 | 2.3 | 50,400 |
| 47F | 3.1 | 56,000 | 3.3 | 8,100 | 3.17 | 64,500 |
| 95F | 2.93 | 54,000 | 2.18 | 11,400 | 2.57 | 56,300 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $4,577 |
| Energy cost | - |
| Total cost | - |
|
ACiQ 54k BTU Central Ducted
$5,150
at HVACDirect
|
ACIQ |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 0.86 | 6,700 | - | - | 1.46 | 30,900 |
| 5F | 1.8 | 52,000 | 1.72 | 14,200 | 1.8 | 52,000 |
| 17F | 2.4 | 45,000 | 2.61 | 16,400 | 2.3 | 50,400 |
| 47F | 3.1 | 56,000 | 3.3 | 8,100 | 3.17 | 64,500 |
| 95F | 2.93 | 54,000 | 2.18 | 11,400 | 2.57 | 56,300 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $5,150 |
| Energy cost | - |
| Total cost | - |
|
MRCOOL MVP Series 54k BTU Central Ducted
$4,599
at HVACDirect
|
MRCOOL |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 0.86 | 6,700 | - | - | 1.46 | 30,900 |
| 5F | 1.8 | 52,000 | 1.72 | 14,200 | 1.8 | 52,000 |
| 17F | 2.4 | 45,000 | 2.61 | 16,400 | 2.3 | 50,400 |
| 47F | 3.1 | 56,000 | 3.3 | 8,100 | 3.17 | 64,500 |
| 95F | 2.93 | 54,000 | 2.18 | 11,400 | 2.57 | 56,300 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $4,599 |
| Energy cost | - |
| Total cost | - |
|
Durastar DRU Series 54k BTU Central Ducted
$6,944
at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 0.86 | 6,700 | - | - | 1.46 | 30,900 |
| 5F | 1.8 | 52,000 | 1.72 | 14,200 | 1.8 | 52,000 |
| 17F | 2.4 | 45,000 | 2.61 | 16,400 | 2.3 | 50,400 |
| 47F | 3.1 | 56,000 | 3.3 | 8,100 | 3.17 | 64,500 |
| 95F | 2.93 | 54,000 | 2.18 | 11,400 | 2.57 | 56,300 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $6,944 |
| Energy cost | - |
| Total cost | - |
|
Cooper & Hunter 57k BTU Central Ducted
$4,210
at MiniSplitWarehouse
|
COOPER&HUNTER |
R-410A |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -4.0F | 1.84 | 6,400 | - | - | 1.44 | 23,600 |
| 5F | - | - | 1.91 | 10,300 | 1.9 | 34,500 |
| 17F | 2.48 | 37,800 | 2.51 | 11,800 | 2.48 | 37,800 |
| 47F | 3.4 | 60,000 | 3.55 | 15,500 | 2.83 | 60,400 |
| 95F | 2.81 | 57,000 | 3.05 | 13,000 | 2.81 | 60,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $4,210 |
| Energy cost | - |
| Total cost | - |
|
Midea 55k BTU Central Ducted
$5,999
at MiniSplitWarehouse
|
MIDEA |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.32 | 12,000 | - | - | 1.28 | 21,300 |
| 5F | 1.9 | 35,400 | 2.2 | 19,100 | 1.9 | 35,400 |
| 17F | 2.6 | 40,500 | 2.75 | 19,900 | 2.2 | 41,500 |
| 47F | 3.44 | 59,000 | 4.45 | 11,700 | 3.35 | 60,500 |
| 95F | 2.78 | 55,000 | 3.85 | 21,800 | 2.68 | 57,500 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $5,999 |
| Energy cost | - |
| Total cost | - |
|
Midea D5F Series 54k BTU Central Ducted
$5,799
at MiniSplitWarehouse
|
MIDEA |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 0.86 | 6,700 | - | - | 1.46 | 30,900 |
| 5F | 1.8 | 52,000 | 1.72 | 14,200 | 1.8 | 52,000 |
| 17F | 2.4 | 45,000 | 2.61 | 16,400 | 2.3 | 50,400 |
| 47F | 3.1 | 56,000 | 3.3 | 8,100 | 3.17 | 64,500 |
| 95F | 2.93 | 54,000 | 2.18 | 11,400 | 2.57 | 56,300 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $5,799 |
| Energy cost | - |
| Total cost | - |
|
Cooper & Hunter CH Series 55k BTU Compact Ducted
$5,796
at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.38 | 6,400 | - | - | 1.38 | 29,800 |
| 5F | 2.1 | 53,500 | 1.89 | 9,400 | 2.1 | 53,500 |
| 17F | 2.72 | 45,000 | 2.0 | 10,300 | 2.41 | 52,000 |
| 47F | 3.74 | 60,000 | 4.1 | 11,200 | 3.76 | 66,000 |
| 95F | 2.99 | 55,000 | 3.59 | 14,200 | 2.87 | 60,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $5,796 |
| Energy cost | - |
| Total cost | - |
|
ACiQ 55k BTU Compact Ducted
$5,425
at HVACDirect
|
ACIQ |
R454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.38 | 6,400 | - | - | 1.38 | 29,800 |
| 5F | 2.1 | 53,500 | 1.89 | 9,400 | 2.1 | 53,500 |
| 17F | 2.72 | 45,000 | 2.0 | 10,300 | 2.41 | 52,000 |
| 47F | 3.74 | 60,000 | 4.1 | 11,200 | 3.76 | 66,000 |
| 95F | 2.99 | 55,000 | 3.59 | 14,200 | 2.87 | 60,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $5,425 |
| Energy cost | - |
| Total cost | - |
|
ACiQ 54k BTU Central Ducted
$4,750
at HVACDirect
|
ACIQ |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 1.5 | 7,600 | - | - | 1.64 | 29,000 |
| 5F | 1.8 | 38,000 | 2.43 | 14,100 | 1.8 | 38,000 |
| 17F | 2.34 | 33,000 | 2.85 | 17,200 | 1.96 | 35,800 |
| 47F | 3.38 | 54,000 | 7.86 | 26,000 | 3.35 | 55,000 |
| 95F | 2.52 | 54,000 | 3.44 | 21,000 | 2.51 | 55,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $4,750 |
| Energy cost | - |
| Total cost | - |
|
Durastar DRU Series 54k BTU Central Ducted
$5,687
at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 1.5 | 7,600 | - | - | 1.64 | 29,000 |
| 5F | 1.8 | 38,000 | 2.43 | 14,100 | 1.8 | 38,000 |
| 17F | 2.34 | 33,000 | 2.85 | 17,200 | 1.96 | 35,800 |
| 47F | 3.38 | 54,000 | 7.86 | 26,000 | 3.35 | 55,000 |
| 95F | 2.52 | 54,000 | 3.44 | 21,000 | 2.51 | 55,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $5,687 |
| Energy cost | - |
| Total cost | - |
|
Stealth EZ Series 54k BTU Central Ducted
$3,999
at HVACDirect
|
STEALTH |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 1.5 | 7,600 | - | - | 1.64 | 29,000 |
| 5F | 1.8 | 38,000 | 2.43 | 14,100 | 1.8 | 38,000 |
| 17F | 2.34 | 33,000 | 2.85 | 17,200 | 1.96 | 35,800 |
| 47F | 3.38 | 54,000 | 7.86 | 26,000 | 3.35 | 55,000 |
| 95F | 2.52 | 54,000 | 3.44 | 21,000 | 2.51 | 55,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $3,999 |
| Energy cost | - |
| Total cost | - |
|
MRCOOL MVP Series 54k BTU Central Ducted
$4,059
(2 stores)
|
MRCOOL |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 1.5 | 7,600 | - | - | 1.64 | 29,000 |
| 5F | 1.8 | 38,000 | 2.43 | 14,100 | 1.8 | 38,000 |
| 17F | 2.34 | 33,000 | 2.85 | 17,200 | 1.96 | 35,800 |
| 47F | 3.38 | 54,000 | 7.86 | 26,000 | 3.35 | 55,000 |
| 95F | 2.52 | 54,000 | 3.44 | 21,000 | 2.51 | 55,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $4,059 |
| Energy cost | - |
| Total cost | - |
|
Cooper & Hunter CH Series 54k BTU Central Ducted
$5,781
at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.11 | 9,100 | - | - | 1.46 | 30,000 |
| 5F | 2.0 | 53,000 | 2.2 | 19,100 | 2.0 | 53,000 |
| 17F | 2.6 | 41,000 | 2.29 | 12,200 | 2.2 | 51,500 |
| 47F | 3.36 | 59,000 | 3.77 | 9,900 | 3.45 | 66,500 |
| 95F | 2.93 | 54,000 | 2.85 | 13,700 | 2.57 | 58,500 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $5,781 |
| Energy cost | - |
| Total cost | - |
|
Midea D5F Series 54k BTU Central Ducted
$5,189
at MiniSplitWarehouse
|
MIDEA |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.5 | 7,600 | - | - | 1.39 | 23,400 |
| 5F | 1.8 | 38,000 | 2.43 | 14,100 | 1.8 | 38,000 |
| 17F | 2.34 | 33,000 | 2.85 | 17,200 | 1.96 | 35,800 |
| 47F | 3.38 | 54,000 | 7.86 | 26,000 | 3.35 | 55,000 |
| 95F | 2.55 | 54,000 | 3.44 | 21,000 | 2.51 | 55,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $5,189 |
| Energy cost | - |
| Total cost | - |
|
Bosch 54k BTU Central Ducted
$6,625
at GotDuctless
|
BOSCH |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| 3.0F | 1.63 | 9,200 | - | - | 1.76 | 30,800 |
| 5F | 1.8 | 33,200 | 1.64 | 9,400 | 1.8 | 33,200 |
| 17F | 2.26 | 40,500 | 2.85 | 10,900 | 2.26 | 40,500 |
| 47F | 3.2 | 56,000 | 4.03 | 22,000 | 3.1 | 58,000 |
| 95F | 2.88 | 54,000 | 2.92 | 23,000 | 2.53 | 56,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $6,625 |
| Energy cost | - |
| Total cost | - |
|