Mitsubishi Electric M-Series 6k BTU Wall Mount
$2,492
(2 stores)
|
MITSUBISHI ELECTRIC |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -10.0F | 1.98 | 810 | - | - | 1.93 | 9,000 |
| 5F | 2.38 | 12,600 | 2.39 | 1,140 | 2.38 | 12,600 |
| 17F | 3.45 | 6,000 | 2.74 | 1,310 | 2.69 | 14,400 |
| 47F | 4.88 | 9,000 | 4.15 | 1,700 | 3.31 | 20,000 |
| 95F | 6.28 | 6,000 | 4.15 | 1,700 | 3.31 | 14,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $2,492 |
| Energy cost | - |
| Total cost | - |
|
Fujitsu AirStage H-Series 9k BTU Wall Mount
$2,156
at GotDuctless
|
FUJITSU |
R-32 |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| 5F | 2.32 | 10,300 | 2.55 | 2,000 | 2.32 | 10,300 |
| 17F | 3.24 | 7,400 | 2.93 | 1,700 | 2.62 | 12,600 |
| 47F | 4.63 | 12,000 | 5.86 | 2,800 | 2.64 | 14,500 |
| 95F | 4.8 | 9,000 | 6.99 | 3,100 | 3.77 | 12,100 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $2,156 |
| Energy cost | - |
| Total cost | - |
|
Mitsubishi Electric M-Series 9k BTU Wall Mount
$2,465
(2 stores)
|
MITSUBISHI ELECTRIC |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -10.0F | 1.96 | 670 | - | - | 1.95 | 7,450 |
| 5F | 1.8 | 9,600 | 2.29 | 860 | 1.8 | 9,600 |
| 17F | 2.66 | 5,900 | 2.32 | 1,030 | 2.39 | 11,500 |
| 47F | 4.85 | 9,600 | 5.69 | 3,300 | 2.66 | 15,900 |
| 95F | 4.55 | 9,000 | 4.47 | 3,200 | 3.41 | 12,200 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $2,465 |
| Energy cost | - |
| Total cost | - |
|
Mitsubishi Electric M-Series 9k BTU Wall Mount
$1,940
(2 stores)
|
MITSUBISHI ELECTRIC |
R-410A |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -4.0F | 2.12 | 1,230 | - | - | 2.08 | 6,180 |
| 5F | 2.12 | 7,900 | 2.1 | 1,580 | 2.12 | 7,900 |
| 17F | 2.61 | 6,500 | 2.39 | 2,040 | 2.43 | 10,200 |
| 47F | 4.44 | 10,900 | 5.73 | 4,500 | 2.68 | 15,900 |
| 95F | 4.55 | 9,000 | 4.4 | 3,600 | 3.41 | 12,200 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,940 |
| Energy cost | - |
| Total cost | - |
|
Mitsubishi Electric M-Series 9k BTU Wall Mount
$2,241
(2 stores)
|
MITSUBISHI ELECTRIC |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -10.0F | 1.41 | 480 | - | - | 1.43 | 5,330 |
| 5F | 1.8 | 8,100 | 1.86 | 700 | 1.8 | 8,100 |
| 17F | 2.69 | 6,700 | 2.22 | 910 | 2.15 | 10,200 |
| 47F | 4.44 | 10,900 | 5.69 | 3,300 | 2.68 | 15,900 |
| 95F | 4.55 | 9,000 | 4.47 | 3,200 | 3.41 | 12,200 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $2,241 |
| Energy cost | - |
| Total cost | - |
|
Fujitsu AirStage H-Series 12k BTU Wall Mount
$2,374
at GotDuctless
|
FUJITSU |
R-32 |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| 5F | 2.39 | 10,600 | 2.55 | 2,000 | 2.39 | 10,600 |
| 17F | 3.11 | 8,700 | 2.93 | 1,700 | 2.65 | 13,200 |
| 47F | 4.32 | 14,000 | 5.86 | 2,800 | 2.5 | 15,000 |
| 95F | 3.95 | 12,000 | 6.99 | 3,100 | 3.26 | 13,800 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $2,374 |
| Energy cost | - |
| Total cost | - |
|
ACiQ 9k BTU Wall Mount
$1,495
at HVACDirect
|
ACIQ |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.17 | 2,000 | - | - | 1.11 | 5,100 |
| 5F | 1.8 | 11,500 | 1.72 | 4,100 | 1.8 | 11,500 |
| 17F | 2.71 | 9,800 | 2.22 | 5,300 | 1.75 | 12,800 |
| 47F | 3.74 | 12,000 | 4.84 | 3,800 | 3.35 | 16,000 |
| 95F | 4.55 | 9,000 | 8.57 | 3,800 | 3.35 | 13,500 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,495 |
| Energy cost | - |
| Total cost | - |
|
Senville SENA Series 9k BTU Wall Mount
$1,300
at Amazon
|
SENVILLE |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.17 | 2,000 | - | - | 1.11 | 5,100 |
| 5F | 1.8 | 11,500 | 1.72 | 4,100 | 1.8 | 11,500 |
| 17F | 2.71 | 9,800 | 2.22 | 5,300 | 1.75 | 12,800 |
| 47F | 3.74 | 12,000 | 4.84 | 3,800 | 3.35 | 16,000 |
| 95F | 4.55 | 9,000 | 8.57 | 3,800 | 3.35 | 13,500 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,300 |
| Energy cost | - |
| Total cost | - |
|
Daikin 9k BTU Wall Mount
$2,063
(3 stores)
|
DAIKIN |
R-32 |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 3.74 | 2,300 | - | - | 1.83 | 10,000 |
| 5F | 1.8 | 11,000 | 3.74 | 2,300 | 2.0 | 11,000 |
| 17F | 3.17 | 6,600 | 4.32 | 2,800 | 2.33 | 13,200 |
| 47F | 4.61 | 11,000 | 6.14 | 4,400 | 3.22 | 15,700 |
| 95F | 4.8 | 9,000 | 4.78 | 4,400 | 4.26 | 12,500 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $2,063 |
| Energy cost | - |
| Total cost | - |
|
Cooper & Hunter CH Series 9k BTU Floor Mount
$1,698
at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.04 | 2,700 | - | - | 1.02 | 4,700 |
| 5F | 1.84 | 11,300 | 1.83 | 2,000 | 1.84 | 11,300 |
| 17F | 2.71 | 9,800 | 2.49 | 2,800 | 2.17 | 12,200 |
| 47F | 4.4 | 9,000 | 4.96 | 4,400 | 3.5 | 16,100 |
| 95F | 4.4 | 9,000 | 5.71 | 3,700 | 3.49 | 13,700 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,698 |
| Energy cost | - |
| Total cost | - |
|
ACiQ 9k BTU Floor Mount
$1,900
at HVACDirect
|
ACIQ |
R454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.04 | 2,700 | - | - | 1.02 | 4,700 |
| 5F | 1.84 | 11,300 | 1.83 | 2,000 | 1.84 | 11,300 |
| 17F | 2.71 | 9,800 | 2.49 | 2,800 | 2.17 | 12,200 |
| 47F | 4.4 | 9,000 | 4.96 | 4,400 | 3.5 | 16,100 |
| 95F | 4.4 | 9,000 | 5.71 | 3,700 | 3.49 | 13,700 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,900 |
| Energy cost | - |
| Total cost | - |
|
Durastar DRA Series 9k BTU Floor Mount
$2,169
at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.04 | 2,700 | - | - | 1.02 | 4,700 |
| 5F | 1.84 | 11,300 | 1.83 | 2,000 | 1.84 | 11,300 |
| 17F | 2.71 | 9,800 | 2.49 | 2,800 | 2.17 | 12,200 |
| 47F | 4.4 | 9,000 | 4.96 | 4,400 | 3.5 | 16,100 |
| 95F | 4.4 | 9,000 | 5.71 | 3,700 | 3.49 | 13,700 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $2,169 |
| Energy cost | - |
| Total cost | - |
|
Cooper & Hunter 6k BTU Wall Mount
$1,369
at MiniSplitWarehouse
|
C&H |
R-410A |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| 5F | 2.09 | 7,500 | 1.81 | 2,105 | 2.19 | 8,581 |
| 17F | 2.9 | 8,500 | 2.29 | 2,108 | 2.45 | 10,041 |
| 47F | 3.95 | 7,000 | 4.35 | 3,565 | 3.73 | 13,241 |
| 95F | 4.63 | 6,000 | 2.61 | 3,388 | 3.75 | 12,402 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,369 |
| Energy cost | - |
| Total cost | - |
|
Cooper & Hunter CH Series 9k BTU Floor Mount
$1,577
at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 0.84 | 800 | - | - | 1.42 | 4,600 |
| 5F | 2.27 | 8,600 | 1.78 | 1,700 | 2.27 | 8,600 |
| 17F | 2.9 | 9,000 | 3.35 | 3,200 | 2.49 | 9,600 |
| 47F | 4.32 | 9,000 | 5.54 | 5,100 | 3.38 | 12,700 |
| 95F | 4.71 | 9,000 | 5.86 | 4,000 | 3.86 | 12,900 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,577 |
| Energy cost | - |
| Total cost | - |
|
Gree Pular 9k BTU Wall Mount
$2,103
at HVACDirect
|
GREE |
R-32 |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.39 | 1,800 | - | - | 1.42 | 6,000 |
| 5F | 1.88 | 9,500 | 2.54 | 2,600 | 1.88 | 9,500 |
| 17F | 2.93 | 8,800 | 3.04 | 2,700 | 2.08 | 11,000 |
| 47F | 3.9 | 10,500 | 4.67 | 2,388 | 2.82 | 14,600 |
| 95F | 4.37 | 9,100 | 4.21 | 2,730 | 3.5 | 13,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $2,103 |
| Energy cost | - |
| Total cost | - |
|
Durastar DRA Series 9k BTU Wall Mount
$1,492
at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.07 | 2,000 | - | - | 1.24 | 5,800 |
| 5F | 1.8 | 11,500 | 1.8 | 4,000 | 1.8 | 11,500 |
| 17F | 2.59 | 10,000 | 2.34 | 5,200 | 1.75 | 12,800 |
| 47F | 3.63 | 12,000 | 5.57 | 3,800 | 3.3 | 16,000 |
| 95F | 4.4 | 9,000 | 8.79 | 3,600 | 3.35 | 13,500 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,492 |
| Energy cost | - |
| Total cost | - |
|
Cooper & Hunter CH Series 9k BTU Wall Mount
$1,419
at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.07 | 2,000 | - | - | 1.24 | 5,800 |
| 5F | 1.8 | 11,500 | 1.8 | 4,000 | 1.8 | 11,500 |
| 17F | 2.59 | 10,000 | 2.34 | 5,200 | 1.75 | 12,800 |
| 47F | 3.63 | 12,000 | 5.57 | 3,800 | 3.3 | 16,000 |
| 95F | 4.4 | 9,000 | 8.79 | 3,600 | 3.35 | 13,500 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,419 |
| Energy cost | - |
| Total cost | - |
|
Cooper & Hunter CH Series 9k BTU Wall Mount
$1,419
at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.07 | 2,000 | - | - | 1.24 | 5,800 |
| 5F | 1.8 | 11,500 | 1.8 | 4,000 | 1.8 | 11,500 |
| 17F | 2.59 | 10,000 | 2.34 | 5,200 | 1.75 | 12,800 |
| 47F | 3.63 | 12,000 | 5.57 | 3,800 | 3.3 | 16,000 |
| 95F | 4.4 | 9,000 | 8.79 | 3,600 | 3.35 | 13,500 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,419 |
| Energy cost | - |
| Total cost | - |
|
Fujitsu AirStage H-Series 9k BTU Wall Mount
$1,568
at GotDuctless
|
FUJITSU |
R-32 |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| 5F | 2.29 | 7,100 | 2.64 | 1,800 | 2.29 | 7,100 |
| 17F | 3.07 | 6,400 | 3.21 | 2,300 | 2.64 | 9,000 |
| 47F | 4.19 | 10,000 | 6.39 | 2,400 | 3.38 | 13,600 |
| 95F | 3.66 | 9,000 | 7.57 | 3,100 | 2.9 | 11,200 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,568 |
| Energy cost | - |
| Total cost | - |
|
Durastar DRA Series 9k BTU Floor Mount
$1,757
at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 0.84 | 800 | - | - | 1.42 | 4,600 |
| 5F | 2.27 | 8,600 | 1.78 | 1,700 | 2.27 | 8,600 |
| 17F | 2.9 | 9,000 | 3.35 | 3,200 | 2.49 | 9,600 |
| 47F | 4.32 | 9,000 | 5.54 | 5,100 | 3.38 | 12,700 |
| 95F | 4.71 | 9,000 | 5.86 | 4,000 | 3.86 | 12,900 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,757 |
| Energy cost | - |
| Total cost | - |
|
Midea D5F Series 9k BTU Floor Mount
$1,579
at MiniSplitWarehouse
|
MIDEA |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 0.84 | 800 | - | - | 1.42 | 4,600 |
| 5F | 2.27 | 8,600 | 1.78 | 1,700 | 2.27 | 8,600 |
| 17F | 2.9 | 9,000 | 3.35 | 3,200 | 2.49 | 9,600 |
| 47F | 4.32 | 9,000 | 5.54 | 5,100 | 3.38 | 12,700 |
| 95F | 4.8 | 9,000 | 5.86 | 4,000 | 3.86 | 12,900 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,579 |
| Energy cost | - |
| Total cost | - |
|
Carrier 45M Series 6k BTU Wall Mount
$2,300
at HVACDirect
|
CARRIER |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.09 | 2,300 | - | - | 1.23 | 3,200 |
| 5F | 2.4 | 7,700 | 1.79 | 3,600 | 2.4 | 7,700 |
| 17F | 2.79 | 7,900 | 2.49 | 5,100 | 2.38 | 8,600 |
| 47F | 4.19 | 7,000 | 3.66 | 3,000 | 2.96 | 11,000 |
| 95F | 5.33 | 6,000 | 3.97 | 2,300 | 3.89 | 12,600 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $2,300 |
| Energy cost | - |
| Total cost | - |
|
ACiQ 12k BTU Wall Mount
$1,650
at HVACDirect
|
ACIQ |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.17 | 2,000 | - | - | 1.25 | 5,900 |
| 5F | 1.8 | 11,500 | 1.72 | 4,100 | 1.8 | 11,500 |
| 17F | 2.71 | 9,800 | 2.22 | 5,300 | 1.75 | 12,800 |
| 47F | 3.74 | 12,000 | 4.84 | 3,800 | 3.35 | 16,000 |
| 95F | 3.91 | 12,000 | 8.57 | 3,800 | 3.35 | 13,500 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,650 |
| Energy cost | - |
| Total cost | - |
|
Senville SENA Series 12k BTU Wall Mount
$1,400
at Amazon
|
SENVILLE |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.17 | 2,000 | - | - | 1.25 | 5,900 |
| 5F | 1.8 | 11,500 | 1.72 | 4,100 | 1.8 | 11,500 |
| 17F | 2.71 | 9,800 | 2.22 | 5,300 | 1.75 | 12,800 |
| 47F | 3.74 | 12,000 | 4.84 | 3,800 | 3.35 | 16,000 |
| 95F | 3.91 | 12,000 | 8.57 | 3,800 | 3.35 | 13,500 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,400 |
| Energy cost | - |
| Total cost | - |
|
Cooper & Hunter CH Series 6k BTU Wall Mount
$1,339
at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.09 | 2,300 | - | - | 1.22 | 3,900 |
| 5F | 2.29 | 7,500 | 1.65 | 3,100 | 2.29 | 7,500 |
| 17F | 2.5 | 7,600 | 2.1 | 3,800 | 2.04 | 8,700 |
| 47F | 3.8 | 7,000 | 4.94 | 3,200 | 2.61 | 10,700 |
| 95F | 4.63 | 6,000 | 4.88 | 2,500 | 3.62 | 11,500 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,339 |
| Energy cost | - |
| Total cost | - |
|
Durastar DRA Series 6k BTU Wall Mount
$1,056
at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.09 | 2,300 | - | - | 1.22 | 3,900 |
| 5F | 2.29 | 7,500 | 1.65 | 3,100 | 2.29 | 7,500 |
| 17F | 2.5 | 7,600 | 2.1 | 3,800 | 2.04 | 8,700 |
| 47F | 3.8 | 7,000 | 4.94 | 3,200 | 2.61 | 10,700 |
| 95F | 4.63 | 6,000 | 4.88 | 2,500 | 3.62 | 11,500 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,056 |
| Energy cost | - |
| Total cost | - |
|
Daikin 12k BTU Wall Mount
$2,420
(3 stores)
|
DAIKIN |
R-32 |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 4.07 | 2,500 | - | - | 1.74 | 10,700 |
| 5F | 1.8 | 13,600 | 3.49 | 2,500 | 2.0 | 13,600 |
| 17F | 3.11 | 8,600 | 4.13 | 3,100 | 2.24 | 15,900 |
| 47F | 4.38 | 13,600 | 5.63 | 4,800 | 2.89 | 19,400 |
| 95F | 3.86 | 12,000 | 5.21 | 4,800 | 3.35 | 16,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $2,420 |
| Energy cost | - |
| Total cost | - |
|
ACiQ ES Series 18k BTU Multi-Zone
$2,390
at HVACDirect
|
ACIQ |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 2.28 | 3,500 | - | - | 1.52 | 7,800 |
| 5F | 2.3 | 13,500 | 2.28 | 3,500 | 2.3 | 13,500 |
| 17F | 2.81 | 13,600 | 2.78 | 3,800 | 2.5 | 14,000 |
| 47F | 3.79 | 19,000 | 4.77 | 5,700 | 3.88 | 21,600 |
| 95F | 4.09 | 18,000 | 3.96 | 5,400 | 3.33 | 21,600 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $2,390 |
| Energy cost | - |
| Total cost | - |
|
ACiQ 12k BTU Wall Mount
$1,665
at HVACDirect
|
ACIQ |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.1 | 3,000 | - | - | 1.04 | 4,800 |
| 5F | 1.88 | 11,300 | 1.99 | 2,100 | 1.88 | 11,300 |
| 17F | 2.71 | 9,800 | 2.66 | 2,900 | 2.14 | 12,400 |
| 47F | 3.86 | 12,000 | 4.96 | 4,400 | 3.5 | 16,100 |
| 95F | 3.66 | 12,000 | 5.71 | 3,700 | 3.57 | 14,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,665 |
| Energy cost | - |
| Total cost | - |
|
Durastar DRA Series 12k BTU Floor Mount
$2,386
at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.1 | 3,000 | - | - | 1.04 | 4,800 |
| 5F | 1.88 | 11,300 | 1.99 | 2,100 | 1.88 | 11,300 |
| 17F | 2.71 | 9,800 | 2.66 | 2,900 | 2.14 | 12,400 |
| 47F | 3.86 | 12,000 | 4.96 | 4,400 | 3.5 | 16,100 |
| 95F | 3.66 | 12,000 | 5.71 | 3,700 | 3.57 | 14,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $2,386 |
| Energy cost | - |
| Total cost | - |
|
Cooper & Hunter CH Series 12k BTU Floor Mount
$1,729
at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.1 | 3,000 | - | - | 1.04 | 4,800 |
| 5F | 1.88 | 11,300 | 1.99 | 2,100 | 1.88 | 11,300 |
| 17F | 2.71 | 9,800 | 2.66 | 2,900 | 2.14 | 12,400 |
| 47F | 3.86 | 12,000 | 4.96 | 4,400 | 3.5 | 16,100 |
| 95F | 3.66 | 12,000 | 5.71 | 3,700 | 3.57 | 14,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,729 |
| Energy cost | - |
| Total cost | - |
|
Midea D5F Series 12k BTU Floor Mount
$1,659
at MiniSplitWarehouse
|
MIDEA |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 0.81 | 800 | - | - | 1.42 | 4,600 |
| 5F | 2.51 | 8,900 | 1.78 | 1,700 | 2.51 | 8,900 |
| 17F | 2.87 | 9,000 | 3.35 | 3,200 | 2.49 | 9,600 |
| 47F | 3.91 | 12,000 | 5.54 | 5,100 | 3.15 | 12,900 |
| 95F | 3.74 | 12,000 | 5.86 | 4,000 | 3.37 | 13,100 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,659 |
| Energy cost | - |
| Total cost | - |
|
Cooper & Hunter CH Series 12k BTU Floor Mount
$1,628
at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 0.81 | 800 | - | - | 1.42 | 4,600 |
| 5F | 2.51 | 8,900 | 1.78 | 1,700 | 2.51 | 8,900 |
| 17F | 2.87 | 9,000 | 3.35 | 3,200 | 2.49 | 9,600 |
| 47F | 3.91 | 12,000 | 5.54 | 5,100 | 3.15 | 12,900 |
| 95F | 3.74 | 12,000 | 5.86 | 4,000 | 3.37 | 13,100 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,628 |
| Energy cost | - |
| Total cost | - |
|
ACiQ 9k BTU Wall Mount
$1,060
at HVACDirect
|
ACIQ |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 1.76 | 4,200 | - | - | 1.53 | 5,000 |
| 5F | 2.33 | 8,200 | 2.11 | 3,600 | 2.33 | 8,200 |
| 17F | 2.8 | 8,600 | 2.47 | 3,800 | 2.47 | 10,200 |
| 47F | 3.66 | 10,000 | 5.35 | 4,200 | 3.36 | 14,200 |
| 95F | 4.32 | 9,000 | 4.33 | 3,100 | 3.9 | 10,900 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,060 |
| Energy cost | - |
| Total cost | - |
|
Cooper & Hunter CH Series 9k BTU Wall Mount
$1,299
at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 1.76 | 4,200 | - | - | 1.53 | 5,000 |
| 5F | 2.33 | 8,200 | 2.11 | 3,600 | 2.33 | 8,200 |
| 17F | 2.8 | 8,600 | 2.47 | 3,800 | 2.47 | 10,200 |
| 47F | 3.66 | 10,000 | 5.35 | 4,200 | 3.36 | 14,200 |
| 95F | 4.32 | 9,000 | 4.33 | 3,100 | 3.9 | 10,900 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,299 |
| Energy cost | - |
| Total cost | - |
|
Cooper & Hunter CH Series 9k BTU Wall Mount
$1,299
at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 1.76 | 4,200 | - | - | 1.53 | 5,000 |
| 5F | 2.33 | 8,200 | 2.11 | 3,600 | 2.33 | 8,200 |
| 17F | 2.8 | 8,600 | 2.47 | 3,800 | 2.47 | 10,200 |
| 47F | 3.66 | 10,000 | 5.35 | 4,200 | 3.36 | 14,200 |
| 95F | 4.32 | 9,000 | 4.33 | 3,100 | 3.9 | 10,900 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,299 |
| Energy cost | - |
| Total cost | - |
|
Durastar DRA Series 12k BTU Floor Mount
$1,878
at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 0.81 | 800 | - | - | 1.42 | 4,600 |
| 5F | 2.51 | 8,900 | 1.78 | 1,700 | 2.51 | 8,900 |
| 17F | 2.87 | 9,000 | 3.35 | 3,200 | 2.49 | 9,600 |
| 47F | 3.91 | 12,000 | 5.54 | 5,100 | 3.15 | 12,900 |
| 95F | 3.74 | 12,000 | 5.86 | 4,000 | 3.37 | 13,100 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,878 |
| Energy cost | - |
| Total cost | - |
|
Durastar DRA Series 9k BTU Wall Mount
$1,080
at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 1.76 | 4,200 | - | - | 1.53 | 5,000 |
| 5F | 2.33 | 8,200 | 2.11 | 3,600 | 2.33 | 8,200 |
| 17F | 2.8 | 8,600 | 2.47 | 3,800 | 2.47 | 10,200 |
| 47F | 3.66 | 10,000 | 5.35 | 4,200 | 3.36 | 14,200 |
| 95F | 4.32 | 9,000 | 4.33 | 3,100 | 3.9 | 10,900 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,080 |
| Energy cost | - |
| Total cost | - |
|
Gree Clivia 12k BTU Wall Mount
$2,143
at HVACDirect
|
GREE |
R-32 |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 2.79 | 2,000 | - | - | 1.51 | 7,300 |
| 5F | 1.95 | 11,000 | 3.17 | 2,600 | 1.95 | 11,000 |
| 17F | 2.9 | 10,000 | 3.04 | 2,700 | 2.06 | 12,000 |
| 47F | 3.82 | 12,000 | 5.62 | 3,070 | 3.72 | 14,600 |
| 95F | 3.82 | 12,000 | 4.4 | 2,700 | 3.03 | 15,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $2,143 |
| Energy cost | - |
| Total cost | - |
|
ACiQ 9k BTU Wall Mount
$960
at HVACDirect
|
ACIQ |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 1.24 | 1,100 | - | - | 1.3 | 3,500 |
| 5F | 2.21 | 7,300 | 1.92 | 3,600 | 2.21 | 7,300 |
| 17F | 2.77 | 8,800 | 1.71 | 1,400 | 2.77 | 8,800 |
| 47F | 4.19 | 10,000 | 4.71 | 4,500 | 3.83 | 12,800 |
| 95F | 4.4 | 9,000 | 4.23 | 2,600 | 3.53 | 13,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $960 |
| Energy cost | - |
| Total cost | - |
|
Cooper & Hunter CH Series 9k BTU Ceiling Cassette
$2,083
at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 0.56 | 900 | - | - | 1.1 | 5,100 |
| 5F | 1.83 | 10,600 | 1.85 | 4,100 | 1.83 | 10,600 |
| 17F | 2.44 | 9,000 | 2.17 | 5,100 | 2.0 | 11,900 |
| 47F | 3.71 | 10,900 | 3.71 | 3,800 | 3.02 | 13,900 |
| 95F | 4.25 | 9,000 | 7.82 | 4,000 | 3.29 | 12,900 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $2,083 |
| Energy cost | - |
| Total cost | - |
|
Durastar DRA Series 12k BTU Wall Mount
$1,696
at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.07 | 2,000 | - | - | 1.25 | 5,900 |
| 5F | 1.8 | 11,500 | 1.8 | 4,000 | 1.8 | 11,500 |
| 17F | 2.59 | 10,000 | 2.34 | 5,200 | 1.75 | 12,800 |
| 47F | 3.63 | 12,000 | 4.84 | 3,800 | 3.35 | 16,000 |
| 95F | 3.86 | 12,000 | 8.79 | 3,600 | 3.35 | 13,500 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,696 |
| Energy cost | - |
| Total cost | - |
|
Cooper & Hunter CH Series 12k BTU Wall Mount
$1,449
at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.07 | 2,000 | - | - | 1.25 | 5,900 |
| 5F | 1.8 | 11,500 | 1.8 | 4,000 | 1.8 | 11,500 |
| 17F | 2.59 | 10,000 | 2.34 | 5,200 | 1.75 | 12,800 |
| 47F | 3.63 | 12,000 | 4.84 | 3,800 | 3.35 | 16,000 |
| 95F | 3.86 | 12,000 | 8.79 | 3,600 | 3.35 | 13,500 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,449 |
| Energy cost | - |
| Total cost | - |
|
Cooper & Hunter CH Series 12k BTU Wall Mount
$1,439
at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 1.07 | 2,000 | - | - | 1.25 | 5,900 |
| 5F | 1.8 | 11,500 | 1.8 | 4,000 | 1.8 | 11,500 |
| 17F | 2.59 | 10,000 | 2.34 | 5,200 | 1.75 | 12,800 |
| 47F | 3.63 | 12,000 | 4.84 | 3,800 | 3.35 | 16,000 |
| 95F | 3.86 | 12,000 | 8.79 | 3,600 | 3.35 | 13,500 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,439 |
| Energy cost | - |
| Total cost | - |
|
ACiQ 18k BTU Wall Mount
$1,400
at HVACDirect
|
ACIQ |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 1.32 | 2,300 | - | - | 1.7 | 8,200 |
| 5F | 2.35 | 13,000 | 2.03 | 3,600 | 2.35 | 13,000 |
| 17F | 2.59 | 13,000 | 2.5 | 4,700 | 2.43 | 15,000 |
| 47F | 3.82 | 18,000 | 5.43 | 7,600 | 3.68 | 22,000 |
| 95F | 3.97 | 18,000 | 3.01 | 3,600 | 3.45 | 20,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,400 |
| Energy cost | - |
| Total cost | - |
|
Fujitsu AirStage H-Series 12k BTU Wall Mount
$1,687
at GotDuctless
|
FUJITSU |
R-32 |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| 5F | 2.29 | 8,500 | 2.56 | 2,100 | 2.29 | 8,500 |
| 17F | 2.86 | 8,700 | 4.05 | 2,900 | 2.69 | 11,000 |
| 47F | 3.8 | 14,000 | 6.09 | 2,700 | 3.69 | 17,000 |
| 95F | 3.41 | 12,000 | 6.99 | 3,100 | 2.95 | 13,600 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,687 |
| Energy cost | - |
| Total cost | - |
|
Cooper & Hunter CH Series 18k BTU Wall Mount
$1,799
at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 1.32 | 2,300 | - | - | 1.7 | 8,200 |
| 5F | 2.35 | 13,000 | 2.03 | 3,600 | 2.35 | 13,000 |
| 17F | 2.59 | 13,000 | 2.5 | 4,700 | 2.43 | 15,000 |
| 47F | 3.82 | 18,000 | 5.43 | 7,600 | 3.68 | 22,000 |
| 95F | 3.97 | 18,000 | 3.01 | 3,600 | 3.45 | 20,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,799 |
| Energy cost | - |
| Total cost | - |
|
Cooper & Hunter CH Series 18k BTU Wall Mount
$1,819
at MiniSplitWarehouse
|
COOPER&HUNTER |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 1.32 | 2,300 | - | - | 1.7 | 8,200 |
| 5F | 2.35 | 13,000 | 2.03 | 3,600 | 2.35 | 13,000 |
| 17F | 2.59 | 13,000 | 2.5 | 4,700 | 2.43 | 15,000 |
| 47F | 3.82 | 18,000 | 5.43 | 7,600 | 3.68 | 22,000 |
| 95F | 3.97 | 18,000 | 3.01 | 3,600 | 3.45 | 20,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,819 |
| Energy cost | - |
| Total cost | - |
|
Durastar DRA Series 9k BTU Ceiling Cassette
$2,211
at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -22.0F | 0.56 | 900 | - | - | 1.1 | 5,100 |
| 5F | 1.83 | 10,600 | 1.85 | 4,100 | 1.83 | 10,600 |
| 17F | 2.44 | 9,000 | 2.17 | 5,100 | 2.0 | 11,900 |
| 47F | 3.71 | 10,900 | 3.71 | 3,800 | 3.02 | 13,900 |
| 95F | 4.25 | 9,000 | 7.82 | 4,000 | 3.29 | 12,900 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $2,211 |
| Energy cost | - |
| Total cost | - |
|
Durastar DRA Series 18k BTU Wall Mount
$1,579
at GotDuctless
|
DURASTAR |
R-454B |
| Temp | COP | BTU (rated) | COP (min) | BTU (min) | COP (max) | BTU (max) |
| -13.0F | 1.32 | 2,300 | - | - | 1.7 | 8,200 |
| 5F | 2.35 | 13,000 | 2.03 | 3,600 | 2.35 | 13,000 |
| 17F | 2.59 | 13,000 | 2.5 | 4,700 | 2.43 | 15,000 |
| 47F | 3.82 | 18,000 | 5.43 | 7,600 | 3.68 | 22,000 |
| 95F | 3.97 | 18,000 | 3.01 | 3,600 | 3.45 | 20,000 |
|
| kWh/yr (heat pump) | - |
| kWh suppl. heat | - |
| kWh total/yr | - |
| Hours over capacity | - |
| Hours short cycling | - |
| Purchase cost | $1,579 |
| Energy cost | - |
| Total cost | - |
|