The Federal Heat Pump Tax Credit (25C) Has Ended

The federal 25C tax credit (30% of cost, up to $2,000) ended for heat pumps installed after December 31, 2025. If your system was installed in 2025, you can still claim it on your 2025 return with IRS Form 5695. For new installs, state and utility rebates are what's left, and many still use the same CEE efficiency tiers the credit did. The filter below shows the 35 models in our database that met the credit's northern-region tier, a useful shortlist when a rebate program asks for high efficiency. Set your location on the cost calculator to see incentives available at your ZIP code.

196 heat pumps match this filter. Showing top 50 by SEER2.

NameBrandRefrigerantPerformanceOperation
Carrier 45M Series 6k BTU Wall Mount
$3,400 at HVACDirect
CARRIER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.144,100--1.297,500
5F2.013,5001.159002.013,500
17F2.4111,0001.951,6002.2614,600
47F4.09,0005.864,0003.1917,200
95F5.176,0005.053,1003.516,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,400
Energy cost-
Total cost-
Carrier 45M Series 9k BTU Wall Mount
$3,600 at HVACDirect
CARRIER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.144,100--1.297,500
5F2.013,5001.159002.013,500
17F2.4111,0001.951,6002.2614,600
47F3.5912,0005.864,0003.1917,200
95F4.989,0005.053,1003.516,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,600
Energy cost-
Total cost-
Fujitsu AirStage H-Series 9k BTU Wall Mount
$2,786 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-15.0F2.231,370--1.711,400
5F2.2615,4003.091,9002.2615,400
17F3.67,5003.392,2002.4917,500
47F5.3312,0005.133,5003.0823,000
95F5.59,0008.263,1003.9812,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,786
Energy cost-
Total cost-
Fujitsu AirStage H-Series 12k BTU Wall Mount
$3,051 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-15.0F2.741,400--1.8112,200
5F2.1616,6003.361,9502.1616,600
17F3.4510,0003.392,2002.4418,700
47F4.6416,0005.133,5003.0723,600
95F4.6912,0008.263,1003.8416,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,051
Energy cost-
Total cost-
Gree Airy 9k BTU Wall Mount
$2,932 at HVACDirect
GREE R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F4.232,600--1.647,400
5F2.1111,5004.232,6002.1111,500
17F3.228,9004.322,8002.0613,000
47F4.4410,6005.282,7003.7516,000
95F4.949,1008.372,0003.1614,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,932
Energy cost-
Total cost-
Fujitsu AirStage H-Series 9k BTU Wall Mount
$2,156 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
5F2.3210,3002.552,0002.3210,300
17F3.247,4002.931,7002.6212,600
47F4.6312,0005.862,8002.6414,500
95F4.89,0006.993,1003.7712,100
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,156
Energy cost-
Total cost-
Carrier 45M Series 12k BTU Wall Mount
$3,900 at HVACDirect
CARRIER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.144,100--1.297,500
5F2.013,5001.159002.013,500
17F2.4111,0001.951,6002.2614,600
47F3.5912,0005.864,0003.1917,200
95F4.1912,0005.053,1003.516,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,900
Energy cost-
Total cost-
Gree Airy 12k BTU Wall Mount
$3,114 at HVACDirect
GREE R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F4.232,600--1.758,500
5F2.012,2004.232,6002.012,200
17F3.1110,3004.322,8002.0613,000
47F4.5312,2005.043,2703.7716,200
95F4.4512,00010.622,9003.8317,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,114
Energy cost-
Total cost-
Mitsubishi Electric M-Series 9k BTU Wall Mount
$1,940 (2 stores)
MITSUBISHI ELECTRIC R-410A
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-4.0F2.121,230--2.086,180
5F2.127,9002.11,5802.127,900
17F2.616,5002.392,0402.4310,200
47F4.4410,9005.734,5002.6815,900
95F4.559,0004.43,6003.4112,200
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,940
Energy cost-
Total cost-
Gree Airy 18k BTU Wall Mount
$4,101 at HVACDirect
GREE R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F2.145,100--1.2310,800
5F1.818,0002.496,8001.818,000
17F2.8615,5002.618,0001.920,100
47F4.0118,6005.235,0003.2423,000
95F4.1918,0006.014,1003.1925,590
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$4,101
Energy cost-
Total cost-
Fujitsu AirStage H-Series 12k BTU Wall Mount
$2,374 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
5F2.3910,6002.552,0002.3910,600
17F3.118,7002.931,7002.6513,200
47F4.3214,0005.862,8002.515,000
95F3.9512,0006.993,1003.2613,800
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,374
Energy cost-
Total cost-
Fujitsu AirStage H-Series 14k BTU Wall Mount
$3,274 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-15.0F0.661,900--1.9216,400
5F2.121,0003.492,5002.121,000
17F3.4411,4003.812,6002.3522,000
47F4.5918,0005.074,1503.2625,000
95F4.3414,5006.063,1003.2819,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,274
Energy cost-
Total cost-
Carrier 45M Series 9k BTU Wall Mount
$2,560 at HVACDirect
CARRIER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.172,000--1.115,100
5F1.811,5001.724,1001.811,500
17F2.719,8002.225,3001.7512,800
47F3.7412,0004.843,8003.3516,000
95F4.559,0008.573,8003.3513,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,560
Energy cost-
Total cost-
Senville SENA Series 9k BTU Wall Mount
$1,300 at Amazon
SENVILLE R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.172,000--1.115,100
5F1.811,5001.724,1001.811,500
17F2.719,8002.225,3001.7512,800
47F3.7412,0004.843,8003.3516,000
95F4.559,0008.573,8003.3513,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,300
Energy cost-
Total cost-
Daikin 9k BTU Wall Mount
$2,063 (3 stores)
DAIKIN R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-13.0F3.742,300--1.8310,000
5F1.811,0003.742,3002.011,000
17F3.176,6004.322,8002.3313,200
47F4.6111,0006.144,4003.2215,700
95F4.89,0004.784,4004.2612,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,063
Energy cost-
Total cost-
Durastar DRA Series 9k BTU Floor Mount
$2,169 at GotDuctless
DURASTAR R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.042,700--1.024,700
5F1.8411,3001.832,0001.8411,300
17F2.719,8002.492,8002.1712,200
47F4.49,0004.964,4003.516,100
95F4.49,0005.713,7003.4913,700
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,169
Energy cost-
Total cost-
Gree Airy 22k BTU Wall Mount
$4,318 at HVACDirect
GREE R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-20.0F2.291,720--1.6217,000
5F1.824,0002.493,4001.824,000
17F2.9520,0003.215,8001.9424,000
47F3.9124,0004.055,8003.232,000
95F4.1122,0004.436,8003.331,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$4,318
Energy cost-
Total cost-
Cooper & Hunter 6k BTU Wall Mount
$1,369 at MiniSplitWarehouse
C&H R-410A
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
5F2.097,5001.812,1052.198,581
17F2.98,5002.292,1082.4510,041
47F3.957,0004.353,5653.7313,241
95F4.636,0002.613,3883.7512,402
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,369
Energy cost-
Total cost-
Fujitsu AirStage H-Series 18k BTU Ceiling Cassette
$4,904 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-5.0F4.641,900--2.0614,400
5F2.2817,1004.882,0002.2817,100
17F3.0114,4005.132,1002.4219,300
47F3.8121,6006.493,1002.6124,000
95F4.018,0005.053,1003.0420,100
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$4,904
Energy cost-
Total cost-
Midea DLC-series 18k BTU Wall Mount
$2,731 at MiniSplitWarehouse
MIDEA R-410A
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
5F2.8924,0001.353,5892.8924,000
17F2.8920,2001.835,1251.9824,485
47F4.2820,0003.588,6733.3630,995
95F4.4718,0003.718,2363.2926,934
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,731
Energy cost-
Total cost-
Gree Pular 9k BTU Wall Mount
$2,103 at HVACDirect
GREE R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.391,800--1.426,000
5F1.889,5002.542,6001.889,500
17F2.938,8003.042,7002.0811,000
47F3.910,5004.672,3882.8214,600
95F4.379,1004.212,7303.513,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,103
Energy cost-
Total cost-
Durastar DRA Series 9k BTU Wall Mount
$1,492 at GotDuctless
DURASTAR R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.072,000--1.245,800
5F1.811,5001.84,0001.811,500
17F2.5910,0002.345,2001.7512,800
47F3.6312,0005.573,8003.316,000
95F4.49,0008.793,6003.3513,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,492
Energy cost-
Total cost-
Fujitsu AirStage H-Series 9k BTU Wall Mount
$1,568 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
5F2.297,1002.641,8002.297,100
17F3.076,4003.212,3002.649,000
47F4.1910,0006.392,4003.3813,600
95F3.669,0007.573,1002.911,200
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,568
Energy cost-
Total cost-
Durastar DRA Series 9k BTU Floor Mount
$1,757 at GotDuctless
DURASTAR R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-13.0F0.84800--1.424,600
5F2.278,6001.781,7002.278,600
17F2.99,0003.353,2002.499,600
47F4.329,0005.545,1003.3812,700
95F4.719,0005.864,0003.8612,900
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,757
Energy cost-
Total cost-
Midea D5F Series 9k BTU Floor Mount
$1,579 at MiniSplitWarehouse
MIDEA R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-13.0F0.84800--1.424,600
5F2.278,6001.781,7002.278,600
17F2.99,0003.353,2002.499,600
47F4.329,0005.545,1003.3812,700
95F4.89,0005.864,0003.8612,900
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,579
Energy cost-
Total cost-
Gree Pular 22k BTU Wall Mount
$3,394 at HVACDirect
GREE R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-30.0F1.522,600--2.4914,000
5F2.1319,0002.493,4002.1319,000
17F2.720,0003.45,5702.1122,000
47F3.824,0004.54,3003.1833,600
95F4.022,0004.663,3402.9528,660
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,394
Energy cost-
Total cost-
Carrier 45M Series 18k BTU Wall Mount
$4,600 at HVACDirect
CARRIER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F0.982,400--1.4511,900
5F2.3422,6001.969,3002.3422,600
17F3.0119,3002.2611,5002.3523,200
47F4.4120,0005.369,7003.5729,700
95F4.418,0003.9312,6003.5927,900
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$4,600
Energy cost-
Total cost-
Carrier 45M Series 6k BTU Wall Mount
$2,300 at HVACDirect
CARRIER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.092,300--1.233,200
5F2.47,7001.793,6002.47,700
17F2.797,9002.495,1002.388,600
47F4.197,0003.663,0002.9611,000
95F5.336,0003.972,3003.8912,600
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,300
Energy cost-
Total cost-
Gree Floor ceiling 9k BTU Floor/Ceiling Console
$3,159 at HVACDirect
GREE R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.171,600--1.176,000
5F1.910,5002.052,8001.910,500
17F2.968,9002.344,0001.9813,000
47F4.110,5005.132,8003.1815,500
95F4.179,1007.332,5003.4511,900
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,159
Energy cost-
Total cost-
Carrier 45M Series 12k BTU Wall Mount
$2,700 at HVACDirect
CARRIER R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.172,000--1.255,900
5F1.811,5001.724,1001.811,500
17F2.719,8002.225,3001.7512,800
47F3.7412,0004.843,8003.3516,000
95F3.9512,0008.573,8003.3513,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,700
Energy cost-
Total cost-
Senville SENA Series 12k BTU Wall Mount
$1,400 at Amazon
SENVILLE R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.172,000--1.255,900
5F1.811,5001.724,1001.811,500
17F2.719,8002.225,3001.7512,800
47F3.7412,0004.843,8003.3516,000
95F3.9112,0008.573,8003.3513,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,400
Energy cost-
Total cost-
Durastar DRA Series 6k BTU Wall Mount
$1,056 at GotDuctless
DURASTAR R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.092,300--1.223,900
5F2.297,5001.653,1002.297,500
17F2.57,6002.13,8002.048,700
47F3.87,0004.943,2002.6110,700
95F4.636,0004.882,5003.6211,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,056
Energy cost-
Total cost-
Daikin 12k BTU Wall Mount
$2,420 (3 stores)
DAIKIN R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-13.0F4.072,500--1.7410,700
5F1.813,6003.492,5002.013,600
17F3.118,6004.133,1002.2415,900
47F4.3813,6005.634,8002.8919,400
95F3.8612,0005.214,8003.3516,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,420
Energy cost-
Total cost-
Gree Floor ceiling 9k BTU Floor/Ceiling Console
$2,728 at HVACDirect
GREE R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.171,600--1.376,000
5F1.9510,0001.953,0001.9510,000
17F2.968,8002.344,0002.1611,400
47F4.110,5005.312,9002.7614,300
95F4.179,1006.112,5003.3112,300
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,728
Energy cost-
Total cost-
Durastar DRA Series 12k BTU Floor Mount
$2,386 at GotDuctless
DURASTAR R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.13,000--1.044,800
5F1.8811,3001.992,1001.8811,300
17F2.719,8002.662,9002.1412,400
47F3.8612,0004.964,4003.516,100
95F3.6612,0005.713,7003.5714,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,386
Energy cost-
Total cost-
Durastar DRA Series 12k BTU Floor Mount
$1,878 at GotDuctless
DURASTAR R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-13.0F0.81800--1.424,600
5F2.518,9001.781,7002.518,900
17F2.879,0003.353,2002.499,600
47F3.9112,0005.545,1003.1512,900
95F3.7412,0005.864,0003.3713,100
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,878
Energy cost-
Total cost-
Durastar DRA Series 9k BTU Wall Mount
$1,080 at GotDuctless
DURASTAR R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-13.0F1.764,200--1.535,000
5F2.338,2002.113,6002.338,200
17F2.88,6002.473,8002.4710,200
47F3.6610,0005.354,2003.3614,200
95F4.329,0004.333,1003.910,900
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,080
Energy cost-
Total cost-
Gree Clivia 12k BTU Wall Mount
$2,143 at HVACDirect
GREE R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F2.792,000--1.517,300
5F1.9511,0003.172,6001.9511,000
17F2.910,0003.042,7002.0612,000
47F3.8212,0005.623,0703.7214,600
95F3.8212,0004.42,7003.0315,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,143
Energy cost-
Total cost-
Gree 360° air discharge cassette unit 9k BTU Ceiling Cassette
$3,162 at HVACDirect
GREE R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.321,800--1.356,000
5F1.858,5001.762,7001.858,500
17F2.878,9002.344,0001.7810,200
47F4.010,5005.312,9003.2714,300
95F4.529,1007.332,5003.4511,900
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$3,162
Energy cost-
Total cost-
Durastar DRA Series 12k BTU Wall Mount
$1,696 at GotDuctless
DURASTAR R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.072,000--1.255,900
5F1.811,5001.84,0001.811,500
17F2.5910,0002.345,2001.7512,800
47F3.6312,0004.843,8003.3516,000
95F3.8612,0008.793,6003.3513,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,696
Energy cost-
Total cost-
Gree 18k BTU Compact Ducted
$4,045 at HVACDirect
GREE R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F2.446,000--1.1610,100
5F1.815,5002.638,0001.815,500
17F2.8615,5002.9610,0001.8719,200
47F4.2518,0004.554,5003.4726,613
95F4.0918,0005.334,0003.125,930
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$4,045
Energy cost-
Total cost-
Fujitsu AirStage H-Series 12k BTU Wall Mount
$1,687 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
5F2.298,5002.562,1002.298,500
17F2.868,7004.052,9002.6911,000
47F3.814,0006.092,7003.6917,000
95F3.4112,0006.993,1002.9513,600
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,687
Energy cost-
Total cost-
Durastar DRA Series 9k BTU Ceiling Cassette
$2,211 at GotDuctless
DURASTAR R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F0.56900--1.15,100
5F1.8310,6001.854,1001.8310,600
17F2.449,0002.175,1002.011,900
47F3.7110,9003.713,8003.0213,900
95F4.259,0007.824,0003.2912,900
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,211
Energy cost-
Total cost-
Durastar DRA Series 18k BTU Wall Mount
$1,579 at GotDuctless
DURASTAR R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-13.0F1.322,300--1.78,200
5F2.3513,0002.033,6002.3513,000
17F2.5913,0002.54,7002.4315,000
47F3.8218,0005.437,6003.6822,000
95F3.9718,0003.013,6003.4520,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,579
Energy cost-
Total cost-
Midea DLC-series 9k BTU Ceiling Cassette
$1,841 at MiniSplitWarehouse
MIDEA R-410A
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F0.98500--1.014,800
5F1.810,5002.931,9001.810,500
17F2.359,8003.372,3001.8311,400
47F3.2910,9004.23,3002.9314,000
95F3.829,0005.863,0003.1112,200
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,841
Energy cost-
Total cost-
Durastar DRA Series 16k BTU Floor Mount
$2,227 at GotDuctless
DURASTAR R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-13.0F0.711,000--1.568,000
5F2.1613,1001.562,6002.1613,100
17F2.7514,1002.484,4002.5814,600
47F3.3717,0005.497,3003.6722,900
95F3.6616,0003.134,7003.318,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,227
Energy cost-
Total cost-
Cooper & Hunter CH series 6k BTU Wall Mount
$1,369 at MiniSplitWarehouse
COOPER&HUNTER R-410A
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
5F1.847,1001.883,2001.927,200
17F2.57,5002.234,1002.3810,000
47F3.737,0004.983,4002.8611,400
95F4.46,0003.784,9003.411,500
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,369
Energy cost-
Total cost-
Durastar DRA Series 24k BTU Wall Mount
$1,897 at GotDuctless
DURASTAR R-454B
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-13.0F1.022,200--1.5411,000
5F2.1517,8001.725,1002.1517,800
17F2.519,5002.457,2002.4221,300
47F3.0825,0005.0911,3002.8932,700
95F3.824,0003.319,7003.127,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$1,897
Energy cost-
Total cost-
Gree Console 9k BTU Floor Mount
$2,604 at HVACDirect
GREE R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-22.0F1.171,600--1.376,000
5F1.7510,0001.763,0001.7510,000
17F2.758,9002.094,0001.9312,000
47F3.6210,5005.312,9002.9114,000
95F4.529,1004.162,7003.5812,200
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$2,604
Energy cost-
Total cost-
Fujitsu AirStage H-Series 24k BTU Ceiling Cassette
$6,214 at GotDuctless
FUJITSU R-32
TempCOPBTU (rated)COP (min)BTU (min)COP (max)BTU (max)
-5.0F4.615,500--1.8921,000
5F2.1223,6004.85,9002.1223,600
17F3.2217,8005.076,4002.4126,000
47F3.9227,0003.525,4003.2332,000
95F3.8424,0004.065,4002.9128,000
kWh/yr (heat pump)-
kWh suppl. heat-
kWh total/yr-
Hours over capacity-
Hours short cycling-
Purchase cost$6,214
Energy cost-
Total cost-

Frequently Asked Questions

Is the federal heat pump tax credit still available?

No. The One Big Beautiful Bill Act (July 2025) ended Section 25C for property placed in service after December 31, 2025. A heat pump installed during 2025 can still be claimed on the 2025 tax return (Form 5695); one installed in 2026 or later cannot, even if you paid for it earlier.

What did a heat pump need to qualify?

The credit used CEE (Consortium for Energy Efficiency) tier levels, which means SEER2 and HSPF2 well above code minimum. Southern states had a stricter cooling (SEER2) threshold. The models on this page met the northern requirements; about 41 also met the southern ones. Many utility rebate programs use the same CEE tiers.

What incentives are left?

State and utility rebates. Some states also run income-qualified rebate programs (HEAR and HOMES). Amounts and eligibility vary by ZIP code and change often: the cost calculator lists programs for your location from Rewiring America's data, and dsireusa.org covers state programs.

Browse all heat pumps | ACIQ | AMERICAN STANDARD / MITSUBISHI ELECTRIC | BOSCH | CARRIER | COOPER&HUNTER | DAIKIN | DURASTAR | FUJITSU | GREE | INNOVAIR | LG | MIDEA | MITSUBISHI ELECTRIC | MRCOOL | SENVILLE | STEALTH | STEALTH | STEALTH | WESTINGHOUSE